Application areas: Power semiconductor, papermaking, petrochemicals, high acidity water samples, cation bed effluent
Functional features:
1. Wide measurement range of 1.0 ppb-200 ppm, fully meeting the monitoring requirements for sodium ions in the effluent of the cation bed
2. Use the high-performance new Orion sodium electrode technology to ensure fast and reliable measurement results
3. It has high sensitivity and selectivity, providing reliable and verifiable measurement results, expected sodium ion exceedance alarm, ensuring the effluent quality of the cation bed and improving the operational economy of the cation bed
4. Use the two-point known incremental correction method for simple, high-precision, and fast calibration - allowing your system to quickly return to normal operating mode
5. Extend the service life of reagents and reduce waste disposal costs - Innovative reagent addition design adjusts the pH value of water samples, shields other ion interference, and improves the performance of sodium electrodes
6. Extremely simple to use, ensuring the running time of the system to a certain extent - according to the scrolling prompt line, it is more convenient to set, calibrate, and diagnose menu operations
7. The expansion modules of the sampling system and low concentration testing system comply with the strict certification procedures of QA/QC
8. The instrument does not have complex operating components, reagent pumps, or solenoid valves that are prone to malfunction, minimizing downtime and avoiding expensive spare parts expenses
9. Improved advanced user-friendly interface with detailed calibration, measurement, and diagnostic record information, allowing users to configure as needed
10. Use a large backlit display screen that can clearly read instrument display values even in low light environments
11. The instrument installation is simple and ready to use - the Orion 2111AO has the same installation positioning hole as the original Orion 1811AO, making it easy to upgrade and modify
12. You can choose to add a second channel for pH or conductivity measurement
13. Optional digital communication module to meet users' on-site digital network communication requirements
| Specifications |
| Sodium ion measurement range |
1.0 ppb -200 ppm |
| Accuracy (DKA correction) |
± 5% or 2 ppb (whichever is greater) |
| response time |
Reaching 95% in 2 minutes |
| Water sample requirements |
Temperature: 5-45 ℃ |
| Total alkalinity: less than 250 ppm CaCO3
|
| Inlet pressure: 8-100 PSI (0.6-6.9 bar) |
| Flow rate: 25 mL/min, achieved through pressure regulating valve |
| Water sample inlet: 1/4 "NPTF pipe joint |
| Water sample discharge outlet: 3/4 "NPT external thread |
| output |
Optional: 0-20 mA or 4-20 mA; Linear or logarithmic |
| 3 relays, can be used for high and low alarms, correction/hold/error status prompts |
| Optional digital communication module to connect the instrument to the on-site network |
| Correction method |
Unique DKA calibration method, also capable of single point calibration |
| power supply |
85-132 V AC or 170-264 V AC; 50-60 Hz |
| Electrical interface size |
PG13.5 |
| size |
65×45×27 cm(L×W×D) |
| Ordering Information |
|
|
order No |
order No |
| Basic configuration |
2111AO |
Yang bed sodium meter (or 2111AOEN Yang bed sodium meter with protective box) |
| Suggest purchasing parts |
2111XPCAL |
Calibration kit |
| spare parts |
210045 |
Sodium electrode |
|
210056 |
reference electrode |
|
181073 |
Electrode filling solution |
|
181130 |
reagent |
|
181160 |
diffuser |
|
181140 |
Low sodium standard solution |
|
181141 |
High sodium standard solution |