Airsafe1500A2 is an A2 type secondary biosafety cabinet, which is the first to use a DC motor on a biosafety cabinet without the need for a voltage compensator. It can automatically increase the rotational torque in real time to compensate for the wind speed loss caused by external resistance, ensuring stable wind speed.
Compared to AC motors, DC motors reduce direct energy consumption by 60%; The heat generation is also reduced by 60% compared to AC motors, effectively reducing indoor air conditioning energy consumption.
Product advantages:
❏7-inch touchscreen human-machine interaction interface
⊙ 7-inch touchscreen human-machine interaction interface, one interface can display the real-time running time progress of the fan, the status of the front window, the percentage of the lifespan of the filter and sterilization lamp, control the output and shutdown operations of sockets, lighting, sterilization, and the fan, view operation logs and provide alarm functions without switching interfaces
❏Efficient and energy-saving design
▸Energy saving design - advanced design with ultra-low energy consumption, saving 60% of energy consumption (compared to traditional AC motor design); Reduce 60% of heat emissions (compared to traditional AC motor designs); Unique energy-saving mode (energy-saving mode with 10% energy consumption)
Real time airflow regulation ensures stable inflow and outflow velocities. The pressure sensor filter monitors the airflow measurement through the workspace. Compensate for protection by adjusting airflow according to changes in filter resistance
❏Humanized structural design
▸Moderate height, wind speed speedometer,
▸Large microcomputer control system panel, humanized tilted front window design,
▸Comfortable handrests, spacious workspace,
▸A one-piece workbench with exceptional safety,
▸Design the cleaning position of the front window to reduce maintenance frequency
❏Unique check-in and power-off memory function
When the experimental process needs to be paused, there is no need to shut down. The front window will automatically enter a low-speed energy-saving operation state by closing it, maintaining the cleanliness of the operating area. Once the front window is opened, it immediately enters normal operation mode, effectively improving operational efficiency. If there is an unexpected power outage, it can automatically return to the operating state before the power outage after restoring the power supply, fully protecting personnel safety
❏High qualityULPA filter
Using the United StatesHV Company's high-efficiency, low pressure drop, high-strength, and low boron content air filters extend the service life of the filters while reducing pressure drop
Both air supply and exhaust filters are availableUnique technology of "leak prevention" ensures air cleanliness at ISO level 4 (level 10)
The ULPA filter achieves a retention efficiency of 99.9995% for solid particles with a diameter greater than 0.12 microns
❏Appointment sterilization function
Users can enable one click sterilization reservation. After setting the sterilization reservation time, clicking the sterilization reservation switch will pop up a prompt box to enter the sterilization reservation status. After clicking OK, the system will enter the sterilization reservation status
| Model/Parameters | AirSafe1500A2 |
| Filtration efficiency | ≥99.9995%, @0.12μm |
| Air supply and exhaust filters | ULPA filter |
| air cleanliness | ISO 4 |
| Product execution standards | YY0569(GB 4793.1、GB/T 18268.1) |
| Reduce wind speed | 0.35m/s |
| Inflow wind speed | 0.55m/s |
| noise | Less than 65 dB |
| vibrate | The center position of the tabletop is ≤ 5 μ m |
| power supply | AC220V,1φ,50Hz |
| Opening height of sliding door | 200mm |
| Personnel protection | A. The total bacterial count of the impact sampler is ≤ 10CFU per time |
| B. The total bacterial count of the slit sampler is ≤ 5CFU per time | |
| Protection of the tested product | Total colony count ≤ 5CFU./time |
| Cross infection prevention | Total colony count ≤ 2CFU./time |
| Maximum power (including backup socket) | 1.65KW |
| Rated power (excluding spare sockets) | 0.33KW |
| Internal dimensions (width x depth x height) | 1380×580×798mm |
| External dimensions (width x depth x height) | 1500×807×2240mm |
| Lighting power and quantity | 18W×1 |
| UV lamp power and quantity | 20W×1 |
| illuminance | ≥900LX |
| Outer box structure | High quality cold-rolled steel plate electrostatic powder coating (ivory white) |
| Workspace Structure | High quality 304 stainless steel one-time molding |
| Exhaust direction | eject |
| Net weight | 312KG |
modelAirSafe1500A2The corresponding configuration is:
| Serial Number | name | quantity | unit |
| 1 | host | 1 | tower |
| 2 | fuse | 2 | individual |
| 3 | power line | 1 | individual |
| 4 | Paper materials such as instruction manuals | 1 | share |