Aanderaa turbidity sensor 4112
Turbidity sensor 4112 is used for measuring turbidity in water
Product details

Aanderaa turbidity sensor 4112

Turbidity sensor 4112 is used for measuring turbidity in water. The sensor is designed to be integrated into the Andra Ocean Guardian platform, with an analog signal output of 0-5V. It has four range options, and one of them can be directly installed on the sensor disk at the top of the Ocean Guardian platform.


feature

Optical closed sensing volume

Not sensitive to ambient light underwater

Linear output over 5 years

4 range options available

Optical feedback compensation for temperature drift and aging of optical components

Extremely low voltage drift, no need to adjust

Extremely low power consumption


application

pollution monitoring

Surface water and wastewater quality monitoring

Sediment migration

Ocean profile monitoring

River and creek monitoring

The turbidity sensor 4112 measures turbidity by measuring scattered light from water particles. Due to the good correlation between water turbidity and suspended solids concentration, sediment, algae, and water particle pollution are usually monitored by measuring turbidity. The sensor output signal is a voltage signal, and the strength of this signal is proportional to the turbidity or suspended solids concentration of the water body.

The turbidity sensor 4112 has extremely low power consumption, making it very suitable for applications with limited power supply. The drift of the sensor is between 0 and 1mV, and there is no need to adjust the gain. The unique optical design of the sensor enables it to measure sensitive areas within 5cm of the probe, making it suitable for measurements near the bottom and particularly suitable for applications that are heavily affected by reflection

The turbidity probe 4112 can be directly installed on the top sensor disk of the Ocean Guardian platform, and the sensor output is analog output. After connecting to the Ocean Guardian platform, the output data from the Ocean Guardian platform is engineering data.


blob.png//////


Note: (1) The calibration range of the sensor standard is within the linear range of turbidity from 0-750NTU. If higher concentrations are required, please specify with the manufacturer when ordering.

(2) If there are any changes in the indicator parameters, no further notice will be given.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!