Product Code: 024 Product Name: ARSLDE Clamp Sanitary Electromagnetic Flow Meter Product Specification: ARSLDE Clamp Sanitary Electromagnetic Flow Met
Product details

1、 Application scope of ARSLDE clamp sanitary electromagnetic flowmeter:
ARSLDE clamp electromagnetic flowmeter is mainly used in the food, pharmaceutical and other hygiene industries. Its process often requires long-term use of high-temperature steam for cleaning and disinfection to prevent bacterial growth. Therefore, the connection between pipelines and flowmeters in the hygiene industry generally uses quick couplings, namely clamp type structures.
2、 Principle of ARSLDE clamp sanitary electromagnetic flowmeter:
The ARSLDE clamp sanitary electromagnetic flowmeter is based on Faraday's law of electromagnetic induction: when a conductive liquid cuts magnetic field lines in a magnetic field, an induced potential is generated in the conductor, and the induced potential E is: E=KBVD, where:
K - Instrument constant
B -- Magnetic induction intensity
V - Average flow velocity
D - Inner diameter of pipeline
3、 Characteristics of ARSLDE clamp sanitary electromagnetic flowmeter:
1. The measurement of medium flow rate is not affected by changes in density, viscosity, temperature, pressure, and conductivity of the flow rate. The sensor induced voltage signal is linearly related to the average flow rate, resulting in high measurement accuracy
2. There is no obstruction in the measuring pipeline, so there is no additional pressure loss. There are no movable parts in the measuring pipeline, so the sensor has a long lifespan
3. The sensor of ARSLDE clamp sanitary electromagnetic flowmeter requires a short straight pipe section, which is convenient for installation
4. The sensor part of the ARSLDE clamp sanitary electromagnetic flowmeter only has the inner lining and electrode in contact with the measured liquid. As long as the electrode and inner lining materials are selected reasonably, they can resist corrosion and wear
5. A bidirectional measurement system that can measure both forward and reverse flow rates.
4、 Advantages and unique selling points of ARSLDE clamp sanitary electromagnetic flowmeter product:
1. The most important component of the ARSLDE clamp sanitary electromagnetic flowmeter sensor - the coil - is optimized in design and undergoes the strictest real flow test to ensure the measurement accuracy of the product
2. The signal electrode undergoes thorough electrostatic shielding treatment to ensure that small signals are not interfered by the coil and to guarantee measurement accuracy at low flow rates
3. The coil is isolated from the outside world to ensure its long-term insulation strength, which in turn guarantees the long-term measurement accuracy of the sensor
4. All welding processes for the sensor of ARSLDE clamp sanitary electromagnetic flowmeter are carried out using argon arc welding technology. Although the cost is high, it can ensure the reliability of welding (welding is the main production process of the sensor), especially the last welding process after installing the coil. Using argon arc welding technology can ensure that the installed coil is not damaged
5. Adopting a grounding electrode structure to form a balanced electrode plane ensures that the entire process of measuring the average speed is limited to the balanced electrode plane, which can effectively eliminate electrical noise interference and provide accurate measurement results
6. Adopt customized double-layer shielded cables
7. Programmable low-frequency rectangular wave excitation improves the stability of flow measurement and reduces power loss
8. High frequency excitation is used for measuring special media (such as slurry) to eliminate clutter interference
9. Adopting a 16 bit embedded microprocessor, it has fast computing speed and high accuracy
10. All digital processing, strong anti-interference ability, reliable measurement, high accuracy
11. Ultra low EMI switching power supply, suitable for a wide range of power supply voltage changes, with good EMC resistance performance
12. Complete all functional designs with a single circuit board, using SMD devices and surface mount SMT (SMT) technology for high circuit reliability
13. High definition backlit Chinese LCD display, displaying cumulative flow rate, instantaneous flow rate, flow percentage, etc
14. Menu operation, easy to use, simple to operate, easy to learn and understand
15. Bidirectional measurement system, with three integrators inside that can display forward cumulative quantity, reverse cumulative quantity, and differential cumulative quantity respectively
16. Equipped with self checking and self diagnostic functions, and displayed on the screen
17. Unique lightning protection design
5、 Selection of ARSLDE clamp sanitary electromagnetic flowmeter:
1. Conductivity of the tested fluid
2. Diameter, working pressure, and working temperature of the sensor
3. Inner lining material, electrode material and type of sensor
6、 Selection of electromagnetic flowmeter:

Specification code describe
enterprise standard ARS
Instrument type LDE Intelligent electromagnetic flowmeter
Instrument type LDM Ordinary electromagnetic flowmeter
Path code -XXX Example: 100 represents DN100. If the diameter is followed by I, it means insertion type, and AI means adjustable insertion type
Electrode form -1 Standard fixed type
2 Scraper type
3 Removable and replaceable
Electrode material 0 stainless steel
1 Platinum Pt
2 Ha Shi B (HB)
3 Tantalum Ta
4 Titanium Ti
5 Ha Shi C (HC)
Lining material 3 chloroprene rubber
4 Polyurethane rubber
5 F4
6 F46
7 F40
8 P0
9 PPS
Rated pressure (MPa) -4.0 DN10-80
1.6 DN100-150
1.0 DN200-1000
0.6 DN1100-2000
0.25 DN2200
operation temperature E <80oC
H <180oC
ground ring -0 No grounding ring
1 There is a grounding ring
protection grade 0 IP65
1 IP68
Converter type 0 Integrated
1 split type
communication 0 not have
1 RS-485
2 Hart
3 PA bus
4 FF bus
Housing material -0 carbon steel
1 stainless steel
Body flange 0 carbon steel
1 stainless steel
Install the matching flange 0 without
1 belt
power supply 0 220VAC
1 24VDC
Instrument range (XXX) Example: (2000) indicates that the maximum flow rate corresponding to 20mA is 2000M3/h