AKC-215 Dynamic Torque Sensor
AKC-215 dynamic torque sensor · resistance strain gauge principle, combined with electronic technology, realizes non-contact power supply and signal o
Product details
·Suitable for measuring dynamic and static torque. The allowable speed is not greater than 10000 revolutions per minute.
·Can measure torque and speed in both directions. The output signal is a frequency signal. Paired with specialized instruments, it can display power.
·Frequency signal output, strong anti-interference ability, stable and reliable performance, long service life.
·The output frequency signal amplitude can be selected from: square wave signal with 0-5V level or open collector output (OC). Torque frequency output range: 10 ± 5kHz (forward and reverse).
·Zero torque: 10 kHz ± 5kHz
·It can measure both static and dynamic torque, with shaft key connections at both ends for easy installation and use.
|
Main technical indicators
|
||||
|
measurement range
|
AKC-215 |
0~5,10,20,50,100,200,300,500,1000,2000,3000,5000 | Nm | |
|
Output signal: Torque: |
10±5 | kHz | ||
| Speed: | 60 pulses per revolution (speed ≤ 5000 revolutions per minute) | |||
| 30 pulses per revolution (5000 revolutions per minute<speed<1000 revolutions per minute) note | ||||
|
Straightness L |
±0.1; ±0.3; ±0.5 | %F. S | ||
|
Lag H |
±0.1; ±0.3; ±0.5 | %F. S | ||
| Repetitive R | ±0.1; ±0.3; ±0.5 | %F. S | ||
|
Operating Temperature |
-10~+60 | ℃ | ||
|
Temperature compensation range |
Room temperature~+60 | ℃ | ||
|
Zero temperature influence |
±0.1 | %F. S/10 ℃ | ||
|
excitation voltage |
±15 | VDC | ||
|
insulation resistance |
2000 | MΩ/100VDC | ||
|
Safety overload rate |
120 | %F. S | ||
| Note: Special requirements can be customized | ||||
![]() |
|
![]() |
![]() |
|
Electrical connection method
|
||
|
connection method
|
Plug socket number | Wire color |
| Input (power) positive terminal | 1 | red |
| land | 2 | white |
| Input (power) negative terminal | 3 | blue |
| Speed signal output | 4 | black |
| Torque signal output | 5 | Huang |
| If the plug socket number or wire color changes, please refer to the sensor calibration certificate for accuracy. | ||