Dongguan Chanlin Electronics Co., Ltd
Home>Products>A8GS-T delayed OFF boat shaped switch
A8GS-T delayed OFF boat shaped switch
Product Category: Omron Boat shaped Switch Product Description: Equipped with the industry's smallest delay OFF function for remote reset boat shaped
Product details

■ Types

Contact method
1-4: Power contact terminals
a. B: Small load contact terminal
+, -: Coil terminal
Signal contact terminal: Single pole single throw (SPST)+Power contact terminal: Double pole single throw (DPST) Minimum packaging unit
Signal contact terminal x 1+power contact terminal x 2

Terminal specifications

Signal contact terminal: CT connector

Power contact terminal: # 187 terminal block (t=0.8)

Signal contact terminal: CT connector

Power contact terminal: welded terminal

Reset function have have
Button marking not have A8GS-T1185K A8GS-T1115K 50 of them

A8GS-T1285K A8GS-T1215K

A8GS-T1385K A8GS-T1315K

Note 1: This is not a typical 3-pole switch, please take note.
(1) The signal contact terminal is only used for ON and OFF status detection of the operating part.
(2) The power contact terminal is a terminal used for switching the ON and OFF of a circuit.
After the operating part is turned off, only applying voltage to the coil inside the switch can turn it off.

RATING

contact

project Resistive load (A)
Rated voltage (V)
Power contact terminal AC 125 16
AC 250 10
Small load contact terminal DC 5 0.2

Note 1. The above rated values are data measured under the following conditions.
(1) Environmental temperature: 20 ± 2 ℃
(2) Environmental humidity: 65 ± 5%
(3) Operating frequency: 7 times/min

Reset Coil

Rated voltage and current Operating voltage range Rated service life Coil resistance (coil temperature 20 ± 2 ℃)
DC5V 455mA DC4.5~5.5V ON : 50~100ms 11Ω±20%
OFF: Minimum 5 seconds

Note 1: Please control the voltage of the coil to be within the operating voltage range and use the power on time within the rated service life. Otherwise, it may damage performance.
Note 2. If you wish to use the power supply voltage within the range of DC5.5V to DC24V, please consult separately.

■ Contact specifications

Small load contact point Power contact point
material gold alloy silver alloy
Contact interval 3mm or more 3mm or more
Minimum applicable load (reference) * DC3V 1mA DC5V 200mA

Use the load when the switch is turned on within a range not lower than the minimum applicable load.
For the minimum applicable load, please refer to "About the use in small loads" in "Please use correctly".

■ Performance

Allowable operating frequency machinery Switch operation: 20 times/min or less, coil operation: 7 times/min or less
electrical Below 7 times per minute
insulation resistance 100M Ω or above (measured with a DC500V insulation resistance meter)
Contact resistance (initial value) Power contact terminal Below 100m Ω (DC6~8V, 1A voltage drop method)
Small load contact terminal Below 100m Ω (DC6~8V, 0.1A voltage drop method)
pressure resistance Between terminals of the same polarity AC2,000V 50/60Hz 1min
Between opposite polarity terminals AC2,000V 50/60Hz 1min
Between the coil and the switch terminal AC4,000V 50/60Hz 1min
Between the charged metal part and the ground AC4,000V 50/60Hz 1min
Vibration * malfunction 10-55Hz dual amplitude 1.5mm (misoperation within 1ms)
Impact * malfunction 300m/s2 or above (misoperation within 1ms)
durable Maximum 1000m/s2
Temperature range for use -10~+55 ℃ (no freezing, no condensation, below 60% RH)
Environmental humidity for use Below 90% RH (+5-35 ℃, without freezing or condensation)
lifetime machinery Switch operation: over 30000 times, coil operation: over 10000 times
electrical Switching operation: more than 10000 times
Protective structure IEC IP40
Contact disconnection time * * Below 100ms
weight A8GS-S □□□□: about 9g, A8GS-P □□□□: about 10g, A8GS-C □□□□: about 11g, A8GS-D □□□□: about 12g

Note 1: The above values are initial values.
Please inquire separately about the experimental conditions.
***** Reset fromThe time it takes for the coil to apply voltage until the contact is disconnected.

(Unit: mm)
A8GS-T1□ 85K

operating characteristic

Action force (OF) 1.0± 0.6N

Note 1. In the above dimensional drawing, the tolerance not indicated is ± 0.4mm.
Note 2. When operating from the OFF state after reset to the ON state, the operating force increases due to the switch structure.
Note 3. For the welded terminal type, only the shape of the central hole of the terminal has been changed, and there have been no changes to the switch, terminal shape, characteristics, etc.
Note 4. The appearance and characteristics of TV-8 certified switches are the same as those of general products.

■ Panel processing diagram

Installation panel thickness: 0.8-2.3mm
To prevent accidental insertion, the installation holes are asymmetric in shape,
Please pay attention to the direction of the protrusion.
Please process the rounded corners R of the panel on the surface of the panel.
Please process the buckle on the back of the panel.

Note 1: The recommended standard material for the panel is SPCC. If flexible materials are used or there are no buckles on the back of the panel, it may result in insufficient fixing force of the panel. Therefore, please set the panel thickness and size after confirming the actual usage conditions.

warn

Do not perform wiring operations while the switch is powered on.

Do not touch the terminals when powered on. Otherwise, it may cause electric shock.

Safety points

·Please use within the electrical rating range.If used beyond the rated value, it will not only reduce the durability of the switch, but also cause heating and burningBad and dangerous. Therefore, the instantaneous voltage and current during use, including on and off, should be consideredWithin the rated range.

Precautions for use

Regarding installation

·One touch installation.

·Do not apply excessive force when installing the switch into the panel.

·Do not remove the switches already installed on the panel and reinstall them on the panel for use.

·When installing switches on the panel, do not apply external force to the buttons to ensure that the load is appliedShell and flange parts.


Regarding wiring

·When using terminal blocks, please use the socket suitable for terminal block # 187 (t=0.8).

·Please use wires of the correct specifications that can meet the load current.

·After wiring, please avoid subjecting the terminal and connector parts to external forces at all times. Otherwise, it may lead toCausing damage and misoperation of the switch.

(Example: Constant external force state caused by excessive winding of steel cables, etc.)

·After wiring, an appropriate insulation distance should be maintained between the switch terminals and other metal parts.

·The coil has polarity, please confirm the polarity before wiring correctly.

·When continuous power is applied in the coil, insulation aging may occur due to coil heating. Therefore, designWhen using the circuit, please ensure that it is continuously powered on for no more than 10 seconds.

·The back electromotive force generated after the coil action may cause damage to semiconductor components and device errors

Action.When controlled by precision semiconductor components, please design additional surge absorption circuits and other circuits.

·When welding manually, please use an electric soldering iron (with a tip temperature of 360 ℃ MAX) to complete the welding within 4 secondsConnect and do not apply external force to the terminals.

·The contact of the soldering iron tip with the root of the terminal can cause deformation of the switch housing and base.

Regarding usage

·Do not apply external forces to the product that may cause it to deform or deteriorate.

·Please avoid dropping the switch or applying abnormal impacts.Otherwise, it will lead to poor movement.

·Do not apply load to the operating part horizontally (diagonally).Otherwise, it will cause damage to the switch.


Regarding storage and usage environment

·To prevent terminal discoloration and other aging and deterioration of this product during storage, please avoid using the following methodsLong term storage and use under the specified conditions.

1. High temperature and humid environment

2. Environments with corrosive gases

3. Places with direct sunlight

4. Places invaded by sea breeze

5. Environment with rapid temperature changes

In addition, this switch is not sealed and should not be installed in places that come into contact with water, oil, and dustInstallation and use.

·Do not freeze or condense the switch.

·Using in places with strong external magnetic fields may result in improper operation. Please use it in its actual stateConfirm.

Regarding the use of small loads in the field

For use with small loads, please refer to the minimum applicable load current and voltage values, and followSet values higher than these.

If surge current is generated during switching, it will cause the contact to consume too quickly and reduce durabilitySex, therefore please insert contact protection lines as needed.

The minimum applicable load is based on the L level as the reference value.

This value represents a fault level with a reliability level of 60% (λ 60).(JIS C5003)

λ 60=0.5 × 10-6/time is the reliability level of 60%, indicating a prediction of 1-2,000,000Below NextThe malfunction.

● Compliant with RoHS directive

It is recorded that products that comply with RoHS do not contain the following six substances.

<Reference>

The conformity judgment of 6 substances is based on the following criteria.

Lead: below 1000ppm

Mercury: below 1000ppm

Cadmium: below 100ppm

Hexavalent chromium: below 1000ppm

PBB: below 1000ppm

PBDE: below 1000ppm