The national drum, guide, and tunnel ventilation fans look to Zibo, and Zibo looks to "Fujiang" fans. After years of effort, Fujiang fans have developed a streamlined equipment system in the factory, including automatic CNC cutting, hydraulic shearing machines, automatic rolling and spinning, mold pressing at the fan inlet and front plate, and electromagnetic heating for bearing installation. Each fan sold by our factory undergoes strict start-up testing before leaving the factory to ensure the effectiveness and service life of each fan.


18-09 fan, 9-12 fanPurpose of use


The 8-09 and 9-12 high-pressure centrifugal fans are specialized fans that are matched with iron furnaces with melting rates of 1, 2, 3, 5, and 7t/h. They can also be used to blow and transport air and non corrosive, non self igniting, and non viscous gases in various furnaces and forging furnaces. Other similar performance fans can also be selected, but the temperature of the conveying medium should not exceed 80 ℃, and the dust and hard particles contained in the medium should not exceed 150mg/m3.
II8-09 fan, 9-12 fanofType and structure

1. The 8-09 and 9-12 types of fans are both single suction. Our factory has designed five machine numbers for the 8-09 type fan, namely 6.8A, 7.1D, 8D, 8.5D, and 9D; Our factory has designed six machine numbers for the 9-12 type fan, including No. 6.8A, 7.1A, 7.4D, 7.7A, 8D, and 9D.
2. Both 8-09 and 9-12 types of fans can be made into two types: clockwise rotation or counterclockwise rotation. Looking from one end of the motor, if the impeller rotates clockwise, the fan should rotate in a symmetrical and clockwise direction, represented by "clockwise", and vice versa, it should be called a counter rotating fan, represented by "counterclockwise".
3. The outlet position of the fan is represented by the outlet angle of the casing. Both "forward" and "reverse" fans can be made into three angles: 0 degrees, 90 degrees, and 180 degrees
4. The 8-09 and 9-12 types of fans are composed of impellers, casings, air inlets, transmission components, seals, and machine bases. For the 8-09 model, machine numbers 7.1, 8, and 8.5 adopt an integral structure, while the 9-12 model, machine numbers 8 and 9, and the 8-09 model, machine number 9, adopt a partially assembled structure.
Impeller - The impeller is designed according to the new high-efficiency forward fan theory. After the impeller is formed, it undergoes static and dynamic balance correction and overspeed operation tests, resulting in smooth and reliable operation.
Shell - welded into a snail shaped whole with ordinary steel plates.
Air inlet - made into a convergent streamlined integral structure, fixed to the front cover plate with bolts.
Transmission group - composed of main shaft, bearing box, coupling, etc. The spindle is made of high-quality steel. For 8-09 type № 7.1 and 8, rolling bearing grease is used for lubrication; For 8-09 type № 8.5, 9 and 9-12 type № 8, 9, rolling bearing lubricating oil is used for lubrication.
If the above machine number, transmission method, export angle, and structure cannot meet your production needs, our factory has the ability and responsibility to redesign and manufacture it for you until you are satisfied.


III8-09 fan, 9-12 fanPerformance selection and application

1. The parameters listed in the performance table of this book are calculated under the conditions of atmospheric temperature t=20 ℃, atmospheric pressure Pa=101.3 × 103pa, and gas density ρ=1.2kg/m3. If the usage conditions do not meet the above requirements, the conversion should be made according to the following formula:
(1) When changing the density ρ and rotational speed n:
???? ?????
(2) When changing the rotational speed n, atmospheric pressure Pa, and gas temperature:
???? ??????
In the formula, Q2, P2, and N2 refer to the total pressure, flow rate, and power listed in the performance table.


2. Before purchasing a fan, it is best for users to measure the actual working conditions of the iron furnace (mainly referring to the pressure coefficient), and then select according to the melting rate, required air volume, and air pressure of the iron furnace to ensure that the purchased air meets the actual needs.
3. The inlet and outlet of the fan are designed and installed with regulating valves or gates. Before starting, the inlet or outlet valve should be closed first, and then gradually opened after reaching normal speed to regulate the performance of the fan. During the regulation process, the current should be strictly controlled and not exceed the standard.
4. The outlet of the fan should be equipped with an outlet expansion cylinder, which is a square to circular pipe section. The expansion taper should be between 8-12 degrees, and then according to the conveying pipeline, the ratio of the cross-sectional area of the conveying pipeline to the cross-sectional area of the fan outlet should be ≥ 2:1.
5. The conveying air pipeline should avoid dead right angle turns and turns near the fan outlet. The starting point of the turn should be 5 times the diameter of the pipeline behind the diffuser, and the turning radius should be about 3 times the diameter of the pipeline.
6. The furnace bottom and gas pipeline must not have leaks, as leaks can cause the system to descend and the motor to overload.

4、 8-09 fan, 9-12 fanInstallation, adjustment, and trial operation
1. Before installation: A comprehensive inspection should be conducted on all components of the fan, such as whether the parts are complete, whether the rotation direction of the impeller and the casing is consistent, whether the connection parts are tight, whether the main parts such as the impeller, main shaft, bearings are damaged, and whether the transmission group is flexible. Any problems discovered should be fixed immediately.
2. During installation: Pay attention to checking the casing. There should be no tools or debris falling in or left inside the casing. In order to prevent rust and reduce disassembly difficulties on some joint surfaces, a layer of lubricating grease or mechanical oil should be applied. The critical connections between the fan and the ground, as well as between the inlet and outlet ducts and the fan, should be carefully adjusted to ensure natural fit. Forced connections are not allowed, and the weight of the ducts should not be added to any components of the fan. Attention should be paid to ensuring the horizontal position of the fan spindle.
3. Installation requirements:
(1) When installing the fan, the levelness of the main shaft must be checked to ensure it meets the range of 0.20-1000mm.
(2) The sealing clearance at the inlet of the fan impeller should be strictly controlled. The clearance between fans 8-09 No.7.1 and No.8 should be 1.0-1.5mm, while the clearance between fans 8-09 No.8.5 and No.9, and 9-12 No.8 and No.9 should be 1.5-2.0mm.
(3) After installation, test the transmission group and check if there is any tightness or scraping with the fixed parts. If any abnormalities are found, they must be adjusted in a timely manner.
4. Trial operation:
After the installation of all fans is completed and verified to be correct, trial operation can be carried out.
Before operation, the inlet or outlet gate must be closed to allow the fan to start under no-load conditions. After reaching normal speed, if the situation is good, the gate can be gradually opened until the rated working condition is reached. During operation, the current should be strictly controlled and not exceed the standard. After running for 20 minutes, check whether the temperature rise of the bearing box is normal, that is, the temperature rise should not exceed 40 ℃ above room temperature and the gauge temperature should not exceed 70 ℃.
5、 8-09 fan, 9-12 fanOperation and maintenance
1. Before starting the fan, the following preparations should be made:
(1) Close the inlet or outlet valve.
(2) Check the integrity of each component and whether there are any scratches or other phenomena between the rotating and fixed parts.
(3) No one is allowed to stand within 10 meters in the direction of the air inlet and outlet.
(4) All transmission parts, such as pulleys or couplings, must not be exposed and should be covered with protective nets (to be provided by the user).
(5) Children are strictly prohibited from playing on site, and those with slow movements, such as the elderly and disabled, are strictly prohibited from watching.
2. After the fan reaches normal speed, the bearing temperature should be checked regularly. If abnormal phenomena such as severe vibration, impact, rapid increase in bearing temperature, and sudden increase in noise are found, the fan must be stopped urgently.
3. When maintaining the fan, it is necessary to first shut down and cut off the power, and then proceed with construction.
4. Regularly inspect the interior of the fan for dust, dirt, and other impurities, and prevent rusting.
5. Except for changing the lubricating oil (grease) during each disassembly and repair, the lubricating oil (grease) can be replaced according to the actual situation under normal circumstances.
6、 8-09 fan, 9-12 fanMalfunctions and their causes
(1) Severe vibration of the fan:
1. The fan shaft and motor shaft are not concentric.
2. Friction between the casing or air inlet and the impeller.
3. Loose rivets on the impeller or deformation of the impeller.
4. The impeller shaft disc hole and shaft fit are loose.
5. Loose connections in various parts.
6. Poor installation of pipelines.
7. Leaves accumulate dust, dirt or wear severely.
(2) Bearing temperature rise too high:
1. The bearing box vibrates violently.
2. Poor quality, deterioration, improper brand, and insufficient quantity of lubricating oil.
3. The tightening force of the connecting bolts between the bearing box cover and seat is too high or too low.
4. The bearing box is not concentric in front and behind, and the bearing position is tilted and not concentric.
5. Damaged rolling bearings or bent shafts.
6. Friction between the end cap and the shaft.
(3) Excessive motor current or high temperature rise:
1. When driving, the inlet or outlet valve is not closed.
2. The actual operating conditions far exceed the selected operating points.
3. The power grid operates with low voltage or phase loss.
4. Affected by severe vibration of the bearing box.
5. The medium contains viscous substances.
6. The dust and hard particles contained in the medium exceed the standard.


7、 Scope of single machine complete set supply
Overall structure: one fan and one set of foundation bolts.
Partial assembly structure: one fan, one matching motor, one coupling, and one anchor bolt.

eight Ordering Instructions
When placing an order, the fan number, speed, air pressure, air volume, air outlet angle, rotation direction, motor model, power, protection level, installation method, etc. must be specified.
The inlet regulating door of the fan can be selected according to the user's needs, but it must be specified in the purchase contract.

9、 8-09 fan, 9-12 fanOutline dimension drawing and foundation drawing
Please call to request.
ten 8-09 fan, 9-12 fanPrice, manufacturer, and contact information
Zibo Chuanyi Ventilation Equipment Co., Ltd. is a well-known manufacturer of 8-09 fans and 9-12 fans, with excellent product quality and efficient after-sales service. Please call to inquire about the price of the fan. Welcome to our company's main website for more product information.
Phone: 0533-6820280 Fax: 0533-6820126 Email:@ 126.com Contact: Manager Li

11frequently asked questions
Q: Do you have this model of fan in stock?
Answer: There is no stock available. Our production model is based on orders and we do not have inventory. However, we have spare parts for commonly used models and the shortest delivery time is 2 days.

Q: My hometown is far away. How can I receive the goods and how long does the transportation take?

Answer: Zibo City, Shandong Province is one of the important logistics centers in China. There are logistics lines from Zibo to various cities across the country, and wind turbine distribution is safe and fast. It takes 1-2 days to reach provincial capitals around Shandong, 5-7 days to reach northwest, Yunnan Guizhou Sichuan, Guangdong and Guangxi, and 3-6 days to reach southeast coastal areas. Export products can choose Qingdao Port and Huangdao Port, which are very close and can be reached in one day.

Q: How is the product's warranty and after-sales service done?

Answer: Our company advocates the business philosophy of "no need for after-sales service is the best service". Preventing problems before they happen is better than fixing them. Before leaving the factory, all fans undergo strict testing to ensure zero failures.
All products sold come with a one-year warranty period. If there are any quality issues within one year, small fans will bear the round-trip shipping cost and will be returned to the factory for repair or replacement. Large fans will be serviced on-site, leaving you with no worries!

12、 Performance parameter table

8-09Performance table of NO.6.8A, 7.1D, 8D high-pressure centrifugal fans


Machine number

drive
way

rotational speed
r/min

order
name

Total pressure
Pa

internet traffic
m3/h

what is needed
power
kw

motor

model

power
kw

6.8

A

2900

1
2
3
4
5
6
7

10523
11026
11347
11439
11341
11063
10634

675
944
1215
1485
1754
2024
2295

4.62
5.82
7.15
8.63
10.28
11.96
13.60

Y132-2

Y160M1-2

Y160M2-2

7.5

11

15

7.1

D

2900

1
2
3
4
5
6
7
8

11472
12021
12371
12471
12364
12061
11594
11016

768
1075
1383
1690
1997
2304
2612
2919

5.53
6.96
8.71
10.42
12.30
14.35
16.61
18.38

Y132S1-2
Y132S2-2
Y160M1-2

Y160M2-2

Y160L-2

5.5
7.5
11

15

18.5

8

D

2930

1
2
3
4

5
6
7
8

14867
15579
16033
16163

16023
15632
15026
14277

1110
1554
1998
2442

2887
3331
3775
4219

10.36
13.04
16.31
19.51

23.04
26.88
31.11
34.43

Y160M1-2
Y160M2-2
Y160L-2
Y180M-2

Y200L1-2

Y200L2-2

11
15
18.5
22

30

37

8-09NO.Performance Table of 5D and 9D High Pressure Centrifugal Ventilators


Machine number

drive
way

rotational speed
r/min

order
name

Total pressure
Pa

internet traffic
m3/h

what is needed
power
kw

motor

model

power
kw

8.5

D

2950

1
2
3
4
5
6
7
8

17013
17828
18347
18496
18338
17888
17196
(16339)

1341
1877
2414
2950
3487
4023
4560
(5096)

14.32
18.02
22.54
26.97
31.85
37.15
43.00
(47.59)

Y160M2-2
Y160L-2
Y200L1-2

Y200L2-2
Y225M-2

15
18.5
30

37
45

9

D

2950

1

2
3
4

5
6
7
8

19073

19988
20569
20736

20558
20054
19278
18318

1591

2228
2865
3502

4138
4775
5412
6049

19.05

23.98
30.00
35.90

42.37
49.44
57.22
63.33

Y180M-2

Y200L1-2

Y200L2-2

Y225M-2
Y250M-2
Y280S-2

22

30

37

45
55
75

9-12Performance table of NO.6.8A, 7.1A, 7.4D high-pressure centrifugal fans


Machine number

drive
way

rotational speed
r/min

order
name

Total pressure
Pa

internet traffic
m3/h

what is needed
power
kw

motor

model

power
kw

6.8

A

2930

1
2
3
4
5
6
78

11590
11820
12000
12140
12120
11980
11740

1700
2160
2620
3080
3540
4000
4460

9.32
11.59
13.57
15.93
18.27
20.55
22.60

Y160M2-2

Y160L-2

Y180M-2

15

18.5

22

7.1

A

2900

1
2
3
4
5
6
7

12347
12661
12807
12896
13024
12935
12739

2074
2658
3000
3242
3826
4410
4990

12.10
15.02
16.43
18.02
21.14
24.30
27.65

Y160M2-2

Y160L-2

Y180M-2
Y200L1-2

15

18.5

22
30

7.4

D

2900

1
2
3

4
5
6
7

13416
13749
14004

14142
14053
13838
13465

2349
3010
3371

4332
4993
5654
6315

14.88
18.47
22.16

25.99
29.89
33.99
38.07

Y160M2-2
Y160L-2
Y180M-2

Y200L1-2

Y200L2-2
Y225M-2

15
18.5
22

30

37
45

9-12Performance Table of High Pressure Centrifugal Fan


Machine number

drive
way

rotational speed
r/min

order
name

Total pressure
Pa

internet traffic
m3/h

what is needed
power
kw

motor

model

power
kw

7.7

A

2930

1
2
3
4
5
6
7

14543
14887
15171
15319
15220
14985
14583

2349
3010
3671
4332
4993
5654
6315

15.81
19.60
23.52
27.59
31.72
36.07
40.40

Y180M-2

Y200L1-2

Y200L2-2

Y225M-2

22

30

37

45

8

D

2950

1
2
3
4
5
6

16216
16528
16931
17096
16931
16729

2996
3824
4651
5478
6306
7133

22.97
28.24
33.98
39.78
45.52
51.83

Y200L1-2

Y200L2-2
Y225M-2

Y250M-2

30

37
45

55

7

(16216)

(7960)

(57.84)

9

D

2970

1

2

3
4
5

20803

21202

21719
21931
21719

4295

5481

6667
7853
9039

42.24

51.93

62.48
73.15
83.71

Y225M-2

Y250M-2

Y280S-2

Y280M-2

45

55

75

90

6
7

(21461)
(20808)

(10225)
(11411))

(95.31)
(106.40)

Note: Brackets are generally not used.