feature1:Support transparent transmission.
thisThe mode needs to be coordinated with the communication protocol library of the upper computer configuration software, supporting a massive number of servos, frequency convertersPLC、 Sensors and other equipment.
feature2:This gateway's serial communication does not rely on Ethernet side clients.
data sharingpatterndownThe serial port runs autonomously according to the configuration and will not stop working on the serial port side due to client communication interruption.
feature3:The data refresh of this gateway does not depend on the Ethernet side client.
data sharingpatterndownThis gateway uses data sharing to read data and is not transmitted through transparent protocols, so it is not affected by congestion on the Ethernet client side.
feature4:This gateway data will not be lost on-site due to Ethernet side client issues.
data sharingpatterndownWhen the Ethernet client fails, this gateway has a certain amount of data cache, which can be uploaded after the system is restored to avoid losing on-site data and improve system stability.
feature5:suitableMESInterface and data configuration required for data.
Information integration system software that works in conjunction with gateways and has specialized features forMESThe data interface for system design.
net口Performance:
nNumber of ports:2(Built in switch)
nSupported protocols:MODBUS TCPThe server;
nMaximum number of connections:6
nSupport Function Code:01H,02H,03H,04H,05H,06H,0FH,10H;
nIO data space:
uZero zone:8192bit
uArea 1:8192bit
uThree zones:2000character
uFour zones:2000character
nSlave addressing methods: data area addressing (based on address mapping table), remote slave addressing (transparent addressing method)
nSupport the function of instant data transmission
Ethernet portadoptRJ45 connector, parallel wire, cross wirecanAdaptive. If you want a more stable communication guarantee and stronger anti-interference ability, it is recommended to use industrial Ethernet cables. Industrial Ethernet cables come with a shielding layer, which has a strong ability to block external signals and resist interference. Using this type of cable can greatly improve the stability of communication systems.
1.1Serial port performance
lConnector:RJ45, with green colorLINK(Link Establishment) and OrangeACK(Link activity) indicator light
lNumber of interfaces:6
lCommunication protocolMODBUS RTU
lLevel standard:RS232,RS485
lIs it equipped with a transmitter and receiver indicator light? Yes
lNumber of stations carried:RS232——Every bite1From the station,RS485——Maximum per bite31From the station
lMaximum number of configuration operations:256
lCommunication parameters:
nBaud rate2400、4800、9600、19200、38400、57600、115200 (hardware supports up to)250kbps)
nData bit:8
nCheck bits: odd check, even check, no check
nStop position:1The2
nOperation delay can be configured
nThe waiting timeout time can be configured
lIsolation voltage:1500V
lTerminal resistor: built-in120Ohmic terminal resistor
lPower short circuit protection: Supports
1.2LCD screen diagnostic performance
lColor: monochrome, black text, white backlight
lSize:30mm*23mm
lPixel points:128*64
lDisplay character count:21character/line*8line
1.3Mode Settings
SG-U6C0-1.0Mode settings, please refer to the introduction of the dip switch for specific settings.
Bit 1 isONWhennetwork interfaceTranslate into EnglishStart with default network parametersdefaultIP:192.168.1.15
forOFFThe gateway will be customizedIPAddress operation
Bit 2 isONWhentest mode,Gateway manufactured from the factoryengineeringConfigure startup and run
forOFFWhen configuring the operating mode for customers
Bit 3 isONTime transparent transmission mode
1.4Module power supply
Power supply voltage:24VDC(Allow:19.2VDC~28.8VDC)
lRated current:138mA
lRated power3.3W
1.5Protection level
lProtection Level:IP 20
1.6environmental conditions
lTransportation and storage temperature:-40℃~ +70℃
lOperating Temperature -25℃~ +55℃
lRelative humidity at work: 95%(No condensation)
1.7 mechanical properties
lShell body:ABS+PC
lSize:High:125mmWidth:45 mmDeep:115mm
lWeight:about312g
1.8 EMC rating
lElectrostatic discharge:IEC61000-4-2,contact discharge4kVAir discharge8kV;
lElectric fast pulse group:IEC61000-4-4, 3kV
lSurge immunity:IEC61000-4-5,Line ground2kV, Line Line1kV
Gateway sharedtwoThere are several working modes to flexibly respond to the technical requirements of different engineering sites, including:
Mode one,data sharingMode, based on the principle of memory sharing,Has fast data refresh speed、Simple client programmingspecialpointGateway receptionData on Ethernet and provided to serial portMODBUSProtocol serial port network can be used, and data in the serial port network can also be provided to Ethernet for utilization, achieving interconnection in different networks. The gateway is located on the serial port side asMODBUS RTUUsed by the main station, each serial port can be connected at most31Station equipment,Can be connected together31*6=186TaiwanInMODBUS TCP/IPOne side is used as a server and can be connected simultaneously6The client machine.
Mode 2,Serial Ethernet transparent transmissionpattern,This mode needs to be driven by the communication protocol of the upper computer configuration software and can be implemented by SiemensPLC (MPI、PPIwait)MitsubishiPLC(FXSeriesQSeries, etc.), OmronPLC(CJTheCSTheCPTheCVEtc.), as well as HollysysPLC(LMSeriesLKUpload data of products such as series and multi protocol serial port instruments to the configuration software.
this productMulti protocol equipment networking is commonly used in workshops to build a low-level information network platform for various small-scale applicationsPLCOmron, Mitsubishi, Delta, etc., detection instruments (based onRS232/485TheCAN2.0A/BFree protocol), CNC system, robotic arm access to workshop informationtransformMESProvide solutions.
User Manual for Multi Protocol Ethernet Gateway SG-U6-1.0