▍ brief ↴
YLCT/PT-5031Comprehensive tester for transformer characteristicsIt is a multifunctional on-site testing instrument developed and designed by Shaanxi Yilian Electric based on relevant national regulations and user needs, combined with its own experience and technical strength, specifically for testing the volt ampere characteristics, transformation ratio, polarity, error curve, calculation inflection point, and secondary side circuit inspection of transformers.
YLCT/PT-5031 Transformer Characteristics Comprehensive Tester is easy to operate, accurate and reliable in measurement, and can be used in high temperature, high humidity, and extremely cold environments. It is a cost-effective transformer testing equipment.
▍ Functional Features ↴
◆The instrument is fully automatic, requiring only the setting of test voltage and current values. The equipment automatically boosts voltage/current, records data during the entire testing process, and automatically displays the volt ampere characteristic curve.
◆ Fully functional, capable of testing the volt ampere characteristics of CT/PT, 5%, 10%, and 15% error curves, transformation ratio, polarity, secondary load, secondary circuit, secondary withstand voltage, with automatic calculation of inflection points, filtering and printing of test data, and demagnetization function.
◆ The output voltage is high and the capacity is large. The power output of the equipment is all true voltage and current values, with a standard sine wave waveform and a frequency of 50Hz. It can effectively simulate the real state of the transformer and comply with relevant national maintenance regulations.
◆ The large screen fully localized graphical interface and rotating mouse operation directly display the volt ampere curve graph during testing, with automatic coordinate scaling, clear and beautiful, intuitive and convenient. The panel comes with a printer, which can print the curve graph and test data at any time. Equipped with backlight software adjustment function and built-in date/time function.
◆ Large capacity storage, capable of storing 2000 sets of test data, never lost in case of power failure, with complete functions such as data query, browsing, printing, and clearing. Equipped with RS232 communication interface and USB interface, data can be uploaded to the computer for storage, display, editing, and printing through the interface.
◆ Single machine integration, lightweight, weighing only 20kg, easy to carry, and convenient for mobile testing.
▍ Model/Technical Parameters ↴
model |
Function and Parameters |
||||||||
YLCT/PT -5031 |
|
INPUT VOLTAGE |
Output the highest voltage possible |
Output the maximum current |
power |
measurement accuracy |
|||
CTVolt ampere output |
220V |
0—2500V |
15A |
3kVA |
< 0.5% |
||||
CTVariable ratio output |
220V |
0-8V |
0—600A |
――― |
< 0.5% |
||||
CTVariable ratio measurement |
Display the highest ratio:999.9K:5/1 |
< 0.5% |
|||||||
PTVariable ratio measurement |
Display the highest ratio:999.9K:100、150、100/3、100/√3 |
< 0.5% |
|||||||
Direct resistance measurement |
Zui High Measurement Resistance:0.1-20Ω |
1Ωbelow3% 1Ωthe above<1% |
|||||||
phase angle difference |
Zui small display:0.01divide Accuracy:±10divide |
Ratio difference |
Zui small display:0.01% Accuracy:<0.5% |
||||||
Secondary flow |
electric current:0-200A Time:1~5minute |
Secondary voltage resistance |
Voltage:0-2500V Time:1~5minute |
||||||
operation temperature |
-10~55℃ |
working voltage |
AC220V(±20%)50HZ |
||||||
volume |
420×300×270mm |
weight |
26kg |
YLCT/PT
-5031A
INPUT VOLTAGE
Output the highest voltage possible
Output the maximum current
power
measurement accuracy
CTVolt ampere output
220V
0—1000V
15A
3kVA
< 0.5%
PTVolt ampere output
220V
0—330V
0-5A
3kVA
< 0.5%
CTVariable ratio output
220V
0-8V
0—600A
―――
< 0.5%
PTVariable ratio output
220V
0—1000V
―――
―――
< 0.5%
CTVariable ratio measurement
Display the highest ratio:999.9K:5/1
< 0.5%
PTVariable ratio measurement
Display the highest ratio:999.9K:100、150、100/3、100/√3
< 0.5%
Secondary flow
electric current:0-200A
Time:5minute
Secondary voltage resistance
Voltage:0-1000V
Time:5minute
operation temperature
-10~55℃
working voltage
AC220V(±20%)50HZ
volume
350×240×270mm
weight
20kg
YLCT/PT
-5031E
INPUT VOLTAGE
Output the highest voltage possible
Output the maximum current
power
measurement accuracy
CTVolt ampere output
220V
0—1000V
15A
3kVA
< 0.5%
PTVolt ampere output
220V
0—220V
5A
3kVA
< 0.5%
CTVariable ratio output
220V
0-8V
0—600A
―――
< 0.5%
PTVariable ratio output
220V
0—1000V
―――
―――
< 0.5%
CTVariable ratio measurement
Display the highest ratio:999.9K:5/1
< 0.5%
PTVariable ratio measurement
Display the highest ratio:999.9K:100、150、100/3、100/√3
< 0.5%
Direct resistance measurement
Zui High Measurement Resistance:0-20Ω
1Ωbelow3%
1Ωthe above<1%
phase angle difference
Zui small display:0.01divide
Accuracy:±5divide
Ratio difference
Zui small display:0.01%
Accuracy:<0.5%
Secondary flow
electric current:0-200A
Time:5minute
Secondary voltage resistance
Voltage:0-1000V
Time:5minute
operation temperature
-10~55℃
working voltage
AC220V(±20%)50HZ
volume
350×240×270mm
weight
20kg
▍Transformer characteristic testerWiring Instructions and Methods ↴
1. CT volt ampere wiring diagram

3.Second time replyroadWiring diagram
4. PT volt ampere wiring diagram
5.PT ratio wiring diagram
6.Secondary voltage withstand wiring diagram

7. Secondary direct resistance wiring diagram

8. Secondary load wiring diagram

Yilian Electric specializes in producing comprehensive testers for transformer characteristics Transformer tester, with a wide selection of products and free guidance on usage. Professional in electrical testing for 10 years, looking for a comprehensive transformer characteristic tester Transformer tester, choose Yilian Electric to create high-quality electrical testing products.