XR80Y series universal strain gauge pressure transmitter
Characteristics of XR80Y series universal strain gauge pressure transmitter
*Adopting strain type patch pressure sensitive components*Contact with liquid components using316Made of stainless steel
*Applicable * High85Medium and ambient temperature of ℃*Various types of pressure and electrical connections
*All standard output signals:0-5V;0.5-4.5V;1-5V;**High100V/mofEMCProtection capability
0-10V;4-20mAreach10-90℅Ratio voltage
Technical parameters of XR80Y series universal strain gauge pressure transmitter:
1.performance
range |
500KPa~250MPa |
|
Allow overvoltage |
2Double Full Scale |
After removing the overpressure pressure, all performance remains unchanged (destructive pressure) power10Multiple Full Scale Pressure |
Accuracy (including nonlinearity, hysteresis, and repeatability) |
0.2﹪FS;0.5﹪FS;optional |
|
offset thermal drift |
less than0.01﹪FS/℃ |
|
Thermal drift |
less than0.01﹪FS/℃ |
|
response time |
greater than0.5ms |
|
durability |
>107Secondary full pressure cycle |
|
2. XR80Y series universal strain gauge pressure transmitterElectrical Rules
Nominal output signal |
4-20mA(Two lines) |
0-5V,0.5-4.5V,1-5V |
0-10V |
10-90℅ratio |
Supply Voltage |
8-36V |
8-36V |
12-36V |
5V±0.5V |
Output Impedance |
- |
less than90 |
less than90 |
less than90 |
load |
0-1000 |
greater than10K |
greater than10K |
greater than5K |
3. XR80Y series universal strain gauge pressure transmitterenvironmental condition
Medium temperature range |
-20~85℃ |
Temperature range |
Refer to section25page |
Compensed Temperature Range |
-20~85℃ |
Transportation temperature range |
-20~85℃ |
Magnetic field influence |
Strength in400A/mthe following50HZThe output error caused by AC or DC magnetic fields acting on any axis of the transmitter can be ignored. |
RFIeffect |
The frequency is10KHZ~100MHZThe strength is30V/m(unshielded cable)10V/m)The following RF interference, acting on any axis of the transmitter, causes an output error smaller than the calibrated range+0.1% |
vibration effect |
Vibration frequency20~2000HZ, amplitude2mmAcceleration6g,existx,y,zVibration in any axial direction, every direction3minZero point output changes to * large range+0.1% |
protection grade |
Refer to section25Page (related to the selected electrical connection components) |
4. XR80Y series universal strain gauge pressure transmittermechanical condition
material |
Contact with liquid components |
316stainless steel |
degrees of protection provided by enclosure |
1Cr18Ni19TiOr plastic |
|
Pressure connection |
316stainless steel |
|
Electrical connection |
Refer to section25page |
5. XR80Y series universal strain gauge pressure transmittersize/combination
Electrical connection drawings |
M12*1 |
Hessman connector |
||
|
|
|||
Pressure connection drawing |
M20*1.5 |
G1/4 |
M12*1.5 |
G1/4EDseal |
|
|
|
|
*If you need any other requirements, please negotiate with the company.
*Example diagram of size combination: