WLG stainless steel non negative pressure steady flow tank
WLG non negative pressure steady flow tank, stainless steel non negative pressure steady flow tank, stainless steel steady flow tank, non negative pre
Product details

overview
The urban water supply regulations in our country stipulate to prevent any impact on the water use of surrounding residents and prohibit the direct installation of water pumps on municipal pipelines. In order to solve the problem of water supply equipment being able to be connected in series to the municipal pipeline network without generating negative pressure and without affecting the water use of other users, a non negative pressure stabilizing tank is added between the inlet of the water pump and the municipal pipeline network, so that no negative pressure is generated between the water pump and the municipal pipeline network, and the original pressure of the municipal pipeline network can be fully utilized.
A negative pressure suppressor is installed at the top of the non negative pressure steady flow tank, and the inlet is connected to the inlet of the water pump to achieve self tank water intake. Due to the function of the negative pressure suppressor, the inside of the tank maintains positive pressure in any working state, avoiding the water pump from directly extracting water from the tap water network, protecting the water pump, and avoiding affecting surrounding users. When tap water continuously enters the tank, as the water level rises, the air inside the tank is automatically discharged through the negative pressure suppressor. When the water level rises to a certain level, the negative pressure suppressor automatically shuts off. At this time, tap water still partially enters, and the pressure inside the tank gradually increases until the pressure inside the tank is equal to the pressure of the tap water pipe network. The pressure of the municipal pipe network is directly superimposed on the inlet of the water pump, which is used by the water pump. When the user's water usage increases or the flow pressure of the tap water pipe network decreases, the water level inside the tank will gradually decrease. When the water level drops to a certain value, the negative pressure suppressor will automatically open, connect to the atmosphere, and no negative pressure will be generated inside the tank. The water pump will extract the water from the tank and transport it to the pipe network.


Product Introduction
Steady flow tank, also known as steady flow compensator, is an important component of non negative pressure water supply equipment. No negative pressure tank, the function of the negative pressure tank is to stack and eliminate negative pressure with the municipal pipeline network, eliminate secondary pollution, and intelligently compensate for water flow.

Product Features
1. Low equipment investment, small footprint, no need to build reservoirs or water tanks, no need to configure large pressure tanks, greatly saving system footprint.
2. Sanitary and pollution-free, the tank body is made of stainless steel material, and clean tap water is directly pressurized into the household in a fully enclosed pipeline, without secondary pollution, allowing users to use "safe water".
3. The energy-saving effect is significant. The equipment is directly connected in series with the water supply pipe, and the required pressure is added to the pressure of the primary water supply pipe network in the water plant, resulting in a significant energy-saving effect.
4. Save water resources, no need for regular cleaning, and do not waste water and human resources. Save maintenance costs.
5. Low operating costs. Due to the small selection of booster pumps and the ability to use multiple pumps for water supply, the equipment can directly utilize the city's sequential water supply pressure during low peak periods without the need to start the pump. Therefore, the energy consumption during equipment operation is very low, reducing operating costs.
6. When the water supply is insufficient, the water supply will not stop. The installation is simple, and the equipment only needs to be connected to the inlet and outlet pipes when it arrives on site. The construction period is short and the installation is simple.
7. Easy management and maintenance, the equipment has a public water supply pipeline directly connected to the user's pipeline network. In the event of a power outage, although the booster pump stops working, the primary water supply pressure of the water plant can still maintain the water supply.

Application scope
1. Newly built residential communities or buildings for domestic water use
2. The water supply method that has already been built with pools and tanks has undergone a thorough transformation to eliminate water pollution
3. Production and domestic water use in industrial and mining enterprises
4. Intermediate booster stations for long-distance water supply in urban water supply systems, booster stations for regional water supply networks, and centralized booster stations for high-level regional water supply

Specification and model

name
Specifications
material
thickness
Surface treatment method
stainless steel
No negative pressure
Stable flow tank
φ400*1000
304
3mm
8K sanitary mirror polishing
φ600*1300
304
3mm
8K sanitary mirror polishing
φ800*1500
304
3mm
8K sanitary mirror polishing
φ1000*1800
304
3mm
8K sanitary mirror polishing
φ1200*2200
304
3mm
8K sanitary mirror polishing