1. Application Overview:
VOCs over limit alarm (exhaust pipe) is an intelligent gas sensor imported from the original equipment, which is designed to detect the emissions of unorganized emissions after collection and treatment by a device (installed on the exhaust pipe).VOCs over limit alarmReal time monitoring data and alarm status are transmitted to the safety control center through the gas alarm controller and optional wireless module. It can be widely applied to the monitoring of exhaust pipe emissions after the governance of small and micro enterprises in various industries. Provide multi-level and multi parameter tiered warning and alarm limits for enterprises with clear emission limits (which other enterprises cannot achieve). Customized products can be provided according to user needs.
to configure:
Host
Sound and light alarm (optional)
mounting bracket
GPRS wireless module (built-in)
Outdoor waterproof power adapter (external)
2. Functional Features
The product complies with the VOCs emission control standards for industrial enterprises in Hebei, Shandong, Shaanxi, Beijing, and Tianjin landmarks;
Wireless adopts GPRS (sending SIM card and data), and the data is automatically transmitted to the environmental monitoring department;
The imported photoionization detector used is internationally recognized as an excellent VOCs detector;
The gas alarm controller detects the concentration value of VOC gas in real-time 24 hours a day. When the concentration value reaches or exceeds the alarm point, the controller immediately issues an audible and visual alarm and drives other peripheral devices such as exhaust or solenoid valves to operate, preventing explosions, fires, and poisoning accidents;
Optional explosion-proof design, can be installed in explosion-proof areas, safe and reliable;
Provide quarterly on-site calibration (which other companies cannot achieve) to minimize maintenance to the greatest extent possible;
Scalable optional measuring instrument for temperature, pressure, flow and humidity, accurately sampling temperature, pressure, flow and humidity parameters, analyzing the total daily and monthly emissions of VOCs from fixed sources;
It can store twice as much detection data as its peers, instantly query historical data, and export it on a USB drive for easy analysis of factory emission data;
Remote monitoring, capable of remotely controlling detection instruments and operating them on the central platform;
M-BUS signal output or RS485 digital output, can be uploaded to DCS and PLC systems;
Scalable measurement collection and processing device switch operation status;
The product complies with the national standard GB16297-1996 Comprehensive Emission Standard for Air Pollutants,
GB13223-2011 Emission Standards for Air Pollutants from Thermal Power Plants;
Local standard Tianjin DB12/524-2014 Industrial Enterprise Volatile Organic Compound Emission Control Standard,
Hebei DB13/2322-2016 VOCS Emission Control Standards for Industrial Enterprises,
Shandong DB37/2801.3-2017 Volatile Organic Compound Emission Standards,
Shaanxi DB61/T1061-2017 Volatile Organic Compound Emission Control Standard;
Implement the enterprise standard Q/AML28-2017 VOCS over limit alarm sensing device (volatile organic compound online detector);
Equipment installation and networking shall comply with the "Technical Requirements for Installation and Networking of Non Methane Total Hydrocarbon Online Monitoring System for Fixed Pollution Sources in Shanghai (Trial)" and the "Technical Requirements for Photoionization Detector (PID) Method for Continuous Automatic Monitoring System of Volatile Organic Compound Emissions from Fixed Pollution Sources in Guangzhou Province"
3. Technical indicators
product name |
VOCsExceeding the standardAlarm (exhaust pipe) |
PRODUCT MODEL |
AMLVOC type |
Detect gas |
Volatile Organic Compounds (VOCs) |
Detection Principle |
Principles of PID Optics |
measuring range |
0-20ppm, 0-200ppm optional |
Resolution |
0.01ppm(0~100ppm); |
Sampling method |
Free diffusion detection method |
Inhalation type - external air pump, realizing the detection method of pump suction (optional air pump) |
|
Installation method |
Pipeline flange installation (weldable) |
Indication error |
≤± 3% FS (higher accuracy requirements based on sensor performance) |
Repeatability |
≤±1% |
zero drift |
≤± 1% (FS/year) |
response time |
≤ 20 seconds (T90), (higher requirements based on sensor performance) |
recovery time |
≤ 30 seconds (higher requirement based on sensor performance) |
power supply |
220VAC |
power |
≤20 W |
environmental pressure |
86kPa~106kPa |
ambient temperature |
-20℃~+55℃ |
ambient humidity |
10% to 95% RH (no condensation) |
output signal |
Can connect various alarm controllers, PLCs, DCS and other control systems |
signalling |
Four core shielded cable transmission: capable of transmitting up to 1500 meters Optional TCP/IP transmission, fiber optic transmission, short-range wireless transmission, GPRS wireless transmission, with SMS reminder notification function (optional); |
Alarm method |
Sound and light alarm, optional sound and light alarm, alarm sound:<90 decibels |
Alarm point setting |
A1 alarm value, A2 alarm value; TWA alarm value and STEL alarm value can be set separately |
data record |
Automatic data storage, customizable storage interval, can continuously store 300000 sets of date and time data, optional TF storage card, can store more than 10 million sets of data; |
Data Download |
Support exporting measurement data from USB flash drive |
calibration |
Calibration function for target points ranging from level 2 to level 16 or above, with adjustable calibration values and one click zero adjustment |
Execution standards |
Q/AML28-2017 VOCS over limit alarm sensing device (volatile organic compound online detector) |
quality assurance |
The warranty period is one year, and free maintenance is provided during the warranty period. |