Used Agilent 1100 liquid chromatograph, binary low-pressure liquid chromatograph, Agilent liquid phase accessories
The capillary liquid phase pump system controlled by an electronic flow control valve (EFC) has high accuracy and a wide flow rate range. The column flow rate range is 1-20ul/min; 10-100ul/min (optional)
0.001-2.5m/min (EFC closed state)
High pressure preparation pump system, unit or dual high-pressure preparation pump
Flow rate range: 0.001-100m1/min
● Flow rate range of analytical pump system:
Unit pump: 0.001-10m3/min, binary pump: 0.001-5m3/min, quaternary pump: 0.001-10m3/min
Agilent 1100 series injection system with a complete range of varieties
Standard manual sampler (analytical or preparation type)
● Standard automatic sampler
Sample bottle capacity: up to 100 pieces (2mlx100)
Injection volume: 0.1-100ul (0.1-1800ul) optional
● Micro disc automatic sampler
Sample bottle capacity: 2x96 (orifice plate), 2x386 (orifice plate) or 100x2ml
Injection volume: 0.1-100ul (standard part) 0.1-1500ul optional
● Micro standard automatic sampler/micro disc automatic sampler
Injection volume: 0.01-8ul (standard); 0.01-40ul (optional)
● Constant temperature standard automatic sampler/micro disc automatic sampler
Temperature range: 4-40 ℃ with adjustable step size of 1 ℃
220 type microporous plate automatic sampler - combined chemical sample management system
Sample bottle capacity: up to 12 microplates (96 well plate, 384 well plate) for various specifications of test tubes
Injection volume: 0.1-5ul; 0.1-20ul
Variable wavelength scanning ultraviolet detector (VWD) wavelength range: 190-600nm
Multi wavelength detector (MWD) wavelength range: 190-950nm (dual lamp source)
● Diode Array Detector (DAD)
Wavelength range: 190-950nm (dual light source)
Fluorescence detector (FID) excitation wavelength: 200-700nm; Emission wavelength: 280-900nm Spectral storage: Full spectrum
Differential Refraction Detector (RID) Temperature Control: Room Temperature+5 ℃ to 55 ℃ Built in Automatic Purging Valve and Automatic Solvent Circulation Valve
Electrochemical detector (ECD)
LC/MS quadrupole mass detector (MSD)
LC/MS ion trap mass detector (Trap MSD)
Column temperature box and deaerator components
● Column temperature range: 10 ℃ to 80 ℃ at room temperature Optional: Column switching valve
Vacuum online deaerator
JunqiinstrumentequipmentA new batch of Agilent equipment has arrived, including Agilent 6890 gas chromatograph (equipped with single capillary FID detector; dual capillary FID detector, ECD detector); Agilent 6890N gas chromatograph single capillary FID detector; Equipped with automatic liquid sampler and sampling tower, with a hundred position sample tray; Agilent 7694 headspace sampler (44 stations fully automatic, 6 stations sample heating); Agilent 6890N+5973 gas chromatography-mass spectrometer GCMS Shimadzu QP2010 GCMS, Agilent LC-MS, AB (API) GC-MS, etc.
Before making a purchase, be sure to contact the small shopHelp you find the item you need at a suitable price
contact information 18017027751
www.junqi-sh.com
Specific configuration price, phone contact
Junqi Instrument's new chromatography equipment rental service is currently limited to customers in Jiangsu, Zhejiang, and Shanghai. The rented equipment includesAgilent 5890PGas chromatographAgilent 6890 gas chromatograph Agilent 6890N-5973 gas chromatography-mass spectrometry Yishimitsu QP-2010 gas chromatography-mass spectrometer details consultation Junqi Instrument 18017027751
Updated on September 2, 2020 at 10:22:27