Tetravalent tin online analyzer
Wuxi Dianchuang Technology provides you with the price, model, and user manual of a four valent tin online analyzer. The instrument achieves precise m
Product details
Wuxi Dianchuang Technology Co., LtdDCT-Sn4+The tetravalent tin online analyzer achieves precise measurement of reagents through a visual photoelectric system, overcoming quantitative errors caused by wear of peristaltic pump tubes. At the same time, precise quantification of trace reagents has been achieved, greatly reducing the amount of reagents used.
四价锡在线分析仪

CHARACTERISTICS
DCT-Sn4+
Tetravalent tin online analyzerThe unique design enables this product to have lower failure rates, lower maintenance requirements, lower reagent consumption, and higher cost-effectiveness compared to similar products.Optical components: Choose the rare dual beam used in domestic online monitoring instruments, which is not affected by various environmental factors during detection. Automatically correcting system errors,Improve instrument measurement accuracy, stability, and repeatability.Select valve components: use original imported components from the United States, Japan, or Germany. International mainstream fluid components with smaller dead volume and simpler operation.Measurement component: Accurate measurement of reagents is achieved through a visual photoelectric system, overcoming quantitative errors caused by wear of peristaltic pump tubes; at the same timeAccurate quantification of trace reagents has been achieved, with each dose being only 1-5 milliliters, greatly reducing the amount of reagents used. Temperature control: Imported temperature measuring components are used to form a precise temperature control system, and temperature compensation technology is adopted to overcome the influence of temperature drift and ensure that the sample reaction conditions are more in line with requirements.


II DCT-Sn4+Technical parameters of tetravalent tin analyzer

Technical Parameter
Data indicators
Parameter Description
notes
measureQuantity range
0-0.5 mg/L (can be expanded according to actual conditions)
Can be expanded according to actual situations
Abnormal alarms and power outages will not result in data loss, with touch screen display and command input. After abnormal reset and power failure, the instrument automatically returns to powerAutomatically discharge residual reactants and restore working status.
Measurement period
The measurement cycle is 30 minutes
refinedAccuracy
±10%
repeatability
±10%
sampling period
Time interval and hourly measurement mode
Adjustable from 1 to 9999min
calibration cycle
Adjustable at any interval and time from 1 to 99 days
Maintenance Cycle
Usually once a month, about 60 minutes each time
Environmental requirements
For indoor environments with adjustable temperature, it is recommended to have a temperature range of+5-28 ℃; Humidity ≤ 90% (non condensing)
No condensation
size
Height 1350 x Width 500 x Depth 400mm
power supply
AC220±10%V,50±10%Hz,5A
output
RS-232, RS485, 4-20mA or 0-5V


3、 Advantages of DCT Sn4+tetravalent tin online analyzer
1. The entire software system framework and external facilities of the instrument make human-computer interaction more convenient and functional applications more complete;
2. The pollution caused by different water quality on special sites during the instrument measurement process can be set in real-time, greatly reducing the instrument failure rate caused by this problem and making the measurement data more accurate;
3. The instrument has an automatic calibration mode. After automatic calibration, the instrument returns to automatic mode and runs according to the user's set parameters, without the need for staff to monitor the entire process, greatly reducing maintenance time and improving maintenance efficiency;
4. Instrument measurement of water samples is divided into online mode (i.e. automatic mode) and offline mode (i.e. manual mode). In offline mode, calibration tubes are used for measurement, without the need to remove the water sample tube from the sampling port or cup, making maintenance more convenient;
5. The instrument can store 10000 pieces of data and the data can be exported with just one click;
6. The online mode (i.e. automatic mode) and offline mode (i.e. manual mode) of the instrument store data independently, and the offline mode data is not uploaded to the data acquisition instrument, avoiding the impact of instrument maintenance on uploaded data.