German HEYL online hardness analyzerIt is a fully automated titration method for determining the hardness of water quality. Suitable for water quality testing and control of boiler water, softened water, condensate circulating water, pharmaceutical water, tap water, groundwater, etc.
This is a compact and easy-to-use water quality analysis instrument used for automatic online detection of residual hardness in water quality and quality control of water softening processes. This system controls the selectable limit values based on the principle of titration colorimetry, and provides measurement readings through extinction method. Multiple functions ensure the reliability of real-time operation.
Performance characteristics:
1. The adjustable hardness units are ° dH, ° f, ppmCaCO3, mmol/l.
2. Extremely accurate titration is carried out through a plunger metering pump.
3. Reliable and requires minimal maintenance for operation.
4. Only consume minimal indicators and water.
5. Two adjustable limit values with programmable switch function.
6. Start analysis:
- Automatic periodic intermittent operation (0 to 99 minutes);
- Depends on the water volume (contact type water meter).
7. Supervise the analysis process and issue an error report in case of functional failure.
8. Prevent analysis of 'STOP' from external sources.
9. 500 milliliters of indicator reserve for longer operating times.
10. 0/4 to 20mA analog output terminal, used for connecting recorders.
11. Menu with language options.
Technical parameters:
measuring method |
titration |
measuring range |
Determine based on the selection of reagents |
Measurement method |
Timed measurement, quantitative measurement, external control |
output |
Two sets of programmable setpoints, alarm output points for cleaning the measuring tank or replenishing medication, 4-20mA signal or RS232 interface |
Relay contact capacity: |
4 A |
Inlet water pressure |
0.1 - 8 bar |
Inlet water temperature |
10 - 40 °C |
display |
lcd display |
protection grade |
IP 65 |
power |
Maximum 30VA |
power supply |
230 V or 24 V |
Dimensions (W x H x D) |
380 x 480 x 280 mm |
weight |
9.5 kg |
Measurement range and reagent selection
parameter |
reagent |
0DH (resolution) |
0f (resolution) |
Ppm CaCO3 (resolution) |
Mmol/L (resolution) |
water hardness |
TH2005 |
0.05–0.50(0.01) |
0.09–0.89(0.02) |
0.89–8.93(0.2) |
0.01–0.09(0.01) |
water hardness |
TH2025 |
0.25–2.50(0.05) |
0.45–4.48(0.1) |
4.47–44.7(0.9) |
0.04–0.45(0.01) |
water hardness |
TH2100 |
1.0–10.0(0.2) |
1.79–17.9(0.4) |
17.9–179(3.8) |
0.18–1.79(0.04) |
water hardness |
TH2250 |
2.5–25.0(0.2) |
4.48–44.8(0.4) |
44.8–448(3.8) |
0.45–4.48(0.04) |
Application case:
Reference for other models of Testomat 2000 analyzer
Serial Number |
order No |
model |
notes |
|
TESTOMAT analyzer |
||||
1 |
100122 |
TESTOMAT ® ECO |
Test the hardness of water quality |
|
2 |
100096 |
TESTOMAT ® two thousand |
Similar to Testomat ECO |
|
3 |
100704 |
TESTOMAT ® EVO |
Similar to Testomat ECO |
|
4 |
100301 |
TESTOMAT ® DUO |
Similar to Testomat 2000, TESTOMAT DUO allows the operation of two different types of reagents, if the function of "controlling samples from two different locations" is used. |
|
5 |
100221 |
TESTOMAT ® CAL |
Similar to Testomat 2000, adding calibration function |
|
6 |
100181 |
TESTOMAT ® V |
Online detection of total hardness, built-in positioning controller. |
|
7 |
100241 |
TESTOMAT ® CLF |
Online detection of free chlorine, in compliance with DPD method |
|
8 |
100141 |
TESTOMAT ® CLT |
Online detection of total chlorine, in compliance with DPD method |
|
9 |
100281 |
TESTOMAT ® THCL |
Composite equipment: online detection of total hardness and total chlorine (total chlorine meets DPD method) |
|
10 |
100161 |
TESTOMAT ® Fe |
Online detection of iron content for controlling iron removal |
|
11 |
100321 |
TESTOMAT ® CrVI |
Online detection of hexavalent chromium content for controlling the content of Cr6+in wastewater |
|
12 |
110121 |
TITROMAT ® TH |
Online titration detection of total hardness, using 2 reagents -Hardness up to 896 ppm -There is a particularly high resolution in soft water control |
|
Optional accessories |
||||
13 |
270305 |
SK910(6)0/4-20mA |
4-20mA current output module |
|
14 |
270310 |
RS 910 RS 232 |
RS 232 module |
|
15 |
130010 |
R 230V 50Hz |
CO2 removal device |
|
reagent |
||||
20 |
152005 |
TH 2005 |
500 ml |
2000/ECO |
21 |
152025 |
TH 2100 |
500 ml |
2000/ECO |
22 |
152100 |
TH 2250 |
500 ml |
2000/ECO |
23 |
152250 |
TH 2050 |
500 ml |
2000/ECO |
24 |
153050 |
TC 2050 |
500 ml |
2000/ECO |
25 |
154005 |
TM 2005 |
500 ml |
2000/ECO |
26 |
155100 |
TP 2100 |
500 ml |
2000/ECO |
27 |
155160 |
TH 2500 A |
500 ml |
TITROMAT ® TH |
28 |
155161 |
TH 2500 B |
500 ml |
TITROMAT ® TH |
35 |
156220 |
CrVI 2100 A |
500 ml |
TESTOMAT ® CrVI |
36 |
156221 |
CrVI 2100 A |
500 ml |
TESTOMAT ® CrVI |
37 |
156250 |
Fe 2005 A |
500 ml |
TESTOMAT ® Fe |
38 |
156251 |
Fe 2005 B |
500 ml |
TESTOMAT ® Fe |