Split type trace oxygen analyzer
Brief introduction: The split type trace oxygen analyzer adopts an imported zirconia oxygen sensor, which has the characteristics of no power consumpt
Product details
Details introduction:

Split type trace oxygen analyzerWidely used for online detection and analysis of oxygen content in industries such as air separation nitrogen production, smelting, healthcare, petrochemicals, electronics and power.

Split type trace oxygen analyzerMain features:


1) Friendly human-machine dialogue menu, intuitive and convenient operation;
2
Chinese and English menus, users can freely switch;
3
Adopting imported zirconia oxygen sensors, it has the characteristics of no power consumption, high measurement accuracy, long calibration interval, fast response speed, and small zero drift;
4
Calibration at any point within the range is sufficient, without the need for multiple calibration points, to meet the measurement accuracy of the entire range;
5
Restore the factory settings function to prevent confusion in analyzer parameter settings caused by misoperation;
6
Automatic data storage function, allowing customers to freely access historical data;
7
The upper and lower limit alarm points can be set arbitrarily within the full range;
8
standardRS232(default) orRS485Communication interface, capable of bidirectional communication with computers (optional).

Technical parameters of split type trace oxygen analyzer:


measuring principle

Zirconia dioxide

Display mode

128×64dot matrixLCD

Range optional

0 ~ 10/100/1000ppm1%25%2

O

resolution

0.1ppm

measurement accuracy

0~1000ppm /1.00%/10.00% /25.00% ≤±1% FS

0~100ppm ≤±2% FS

0~10ppm ≤±5%FS

repeatability

≤±1%

response time90T

30S

Analog Output4~20mA.DC500(Non isolated output, load resistance less than)

Ohm)0-10VOutput (non isolated output, load resistance greater than)10K

1Ohm)Programmable dry contact type passive alarm output with large capacity contacts

220VAC/2A

communication interfaceRS232(default) or

RS485

Working power supplyexchangeAC170 ~265V 50/60HzPower consumption is less than

10VA

ambient temperature-10 ~ +50

ambient humidity80

RH

Sample gas temperature0 ~ 200

(When the sampling pipeline is made of stainless steel)

Sampling method

Insertion type (diffusion type)

Sample gas pressure86-106KPa

Stable pressure atmosphere

Sample gas componentsNo flammable gas, no corrosive gas, dust content less than3

1mg/Nm

Specification and sizemeter,155mm×155mm×118mmH×W×D

Dimension135mm×135mmH×W

service life24

Month (under normal usage conditions)

Gas interfaceNPT 1/8

internal thread

Installation method

Embedded installationDisclaimer: Product Introduction on This Website(Including product images, product descriptions, technical parameters, etc)