The problem of plasticizers (phthalates) related to Baijiu products is a hot issue in the current Baijiu industry. The Chinese Baijiu Association analyzed that: through the determination of a large number of * * * * of * * * Baijiu products, Baijiu products basically contain plasticizer ingredients, * * 2.32mg/kg (about 8 times more than the national regulations), * * * 0.495mg/kg (about 1.7 times more than the national regulations), with an average of 0.537mg/kg (about 2 times more than the national regulations). Among them, the content of * * Baijiu is high, and the content of low-grade Baijiu is low. Plasticizer, also known as plasticizer, is a colorless, odorless liquid widely used in industry as a polymer material additive. Since May 2011, six types of phthalate plasticizers, including DEHP, DINP, DNOP, DBP, DMP, and DEP, have been detected in Taiwanese food, and DIDP has been detected in pharmaceuticals. Since then, the "haze" effect of plasticizers has continued to spread. After drinks, Baijiu, convenient food and drugs have been exposed to exceed the standard of plasticizers, their lethality has caused many people to talk about "plastic" discoloration. Excessive levels of plasticizers in food can pose serious harm to the human body. Long term intake of plasticizers can disrupt endocrine disorders, increase liver and kidney burden, cause chronic damage to the immune system, digestive system, and even lead to liver cancer. Its toxicity is 20 times that of melamine. On June 1st last year, the Ministry of Health urgently issued a notice to include phthalates (also known as phthalates) in the list of non edible substances that may be illegally added to food and food additives that are prone to abuse.
Referring to the national standard for the detection of plasticizers in food, the company has absorbed internationally leading chromatographic analysis technology,Committed to developing gas chromatography solutions for food quality analysis and testing, focusing on the detection of plasticizers in various common foods,According to the countryDetermination of Phthalates in Food (GB/T21911-2008),**Time developed routine and rapid detection schemes for plasticizers in Baijiu---Gas Chromatography (GC))The analytical method has the advantages of simple operation, * * speed, good repeatability, high sensitivity, and low instrument cost. It is one of the * * instruments for detecting plasticizers in various distilleries, companies, and laboratories in China,answerPlasticizer in Baijiu—Phthalates (titanium esters) substancesof**analysisDetection has a widely leading position in the domestic chromatography industry.
1Main performance characteristics:
1GC-9860L Special for Testing Plasticizer of Baijiugas chromatographuseIndependent innovationofMicrocomputer automatic controlmoduleSystem, new dual CPU design, original Japanese high integration electronic circuit technology, possessing excellent qualitiesReliability and anti-interference abilityjustDisplay intuitively、easy operationThe design innovation of the instrument breaks the traditional Baijiu (food) plasticizer detection GC-MS)Or liquid chromatography-mass spectrometry (LC-MS))The detection and analysis scheme has unique independent innovation in China.
2TheSpecial gas chromatograph for Baijiu plasticizer detectionEquipped with twoIndependent research and development * * featuresofFilling column vaporization chamber and an independent capillary dedicated system, the design of the vaporization chamber draws inspiration from foreign countriesAdvanced level, possessingminiaturizationofUnique structure of independent innovationDesign, fast heating speednot haveDead corners.manyThe design of the air circuit and large volume column chamber is equipped with a variable frequency intelligent rear door automatic cooling system (from 280)℃Reduced to 50℃Only 5 minutes were needed to achieve near room temperature operation in a meaningful sense.
3Equipped with six independent temperature control systems Suitable for installing multiple temperature control requirements such as conversion furnacesofFive order linear program heating function, suitable for multi-component applicationsWide range Baijiu plasticizer detectionanalysisrequirement.
4* * Power failure among similar productsCut off gas, overheatingProtection function, capable of automatically memorizing set parameters, andIt has a wide range of fault self diagnosis functions, 36 types of self diagnosis information, and can display the cause and handling methods of faults at any time.
5There is no current national standard for the detection of plasticizer (phthalate) in Baijiu, The testing for this mainly refers to the national standardGB/T21911-2008Determination of Phthalates in Food. This standard applies to food16Plant phthalates. The detection limit of each phthalate compound in oil containing samples is1.5mg/kgThe detection limit of each phthalate compound in the oil-free sample is0.1mg/kgThe detection repeatability is not greater than3%At the same time, it complies with the "Health Office Supervision Letter" issued by the General Office of the Ministry of Health(2011)551The residual amount of phthalates specified in the document "No."0.3mg/kg.
6The independently innovated pre-processing and detection analysis scheme has replaced the previous chromatographic analysis------Expensive gas chromatography-mass spectrometry(GC/MS)Or liquid chromatography method(HPLC)It has domestic independent innovation. After enrichment and extraction of the test sample, followed by purification using a solid-phase extraction columnGCConduct testing for qualitative retention time and quantitative external standards.
IITemperature control indicators:
1)Column box: room temperature+5℃-400℃ Accuracy:0.1℃ Higher display accuracy up to0.01℃
2)Sample injector: room temperature+5℃-400℃ Accuracy:0.1℃ Higher display accuracy up to0.01℃
3)Detector: Room temperature+5℃-400℃ Accuracy:0.1℃ Higher display accuracy up to0.01℃
4)Column temperature box volume:248*248*260MM
5)Program temperature rise order: fifth order linear range rise
IIITechnical specifications of detector:
Dihydrogen flame ionization detector(FID): Cylindrical collection electrode structure design, quartz nozzle, extremely responsive
Detection limit:≤8×10-12g/s(HEXADECANE/isooctane) Baseline noise:≤2×10-13A
Baseline drift:≤2×10-12A/30min Linear:≥106
4、 Instrument standard configuration:
1Host:GC-9860LBaijiu plasticizer detection gas chromatograph
2、CD-5Quartz capillary specializedChromatographic column30M*0.25mm*0.25um
3Specialized analysisChromatography workstation(Excluding computer)
4High purity hydrogen generatorZH-300ML(Greater than)99.99%)
5High purity nitrogen generatorZN-300MLOr nitrogen gas cylinder (greater than99.99%)
6Low noise air generatorZA-2000L
7Sample pretreatment device (one set)
8Sample pre-treatment reagents (one set to be prepared)
5GC-9860LAnalysis method of Baijiu plasticizer detection gas chromatograph:
Domestically possessing independent innovationPretreatment and detection methods of plasticizers in Baijiu, usefor a special purposeextractDevice,Enrich phthalate esters in polar matrices such as Baijiu, and establish a solid phase extraction method, so as to have an excellent recovery rate and ensure the accuracy of detection results.
Our company's other analysis plans:
Gas chromatograph:
High purity gas analysis dedicated gas chromatograph┆Specialized gas chromatograph for trace moisture analysis┆Gas chromatograph for natural gas analysis┆Special gas chromatograph for analysis of liquefied petroleum gas┆burngasNaphthaleneAnalysis specific gas chromatograph┆transformerDissolved gas in oilAnalytical gas chromatograph┆Refinery gas analysis dedicated gas chromatograph┆Special gas chromatograph for packaging material product analysis┆PaintOrganic compound detection in Chinagas chromatograph┆Special gas chromatograph for product analysis of power plants and substations┆indoorIn the environmentTVOCDetection gas chromatograph┆Gas chromatograph for component analysis of Baijiu┆Gas chromatograph for the detection of essence and fragrance in Baijiu┆Detection of residual ethylene oxide in medical devices by gas chromatography┆Dimethyl ether detection chromatograph in liquefied gas┆Gas chromatograph for detecting methanol in liquefied gas┆Gas chromatograph for detecting formaldehyde in liquefied gas┆Gas chromatograph for detecting methanol and water in dimethyl ether┆Purity analysis of dimethyl ether using gas chromatography┆Gas chromatograph for detecting alcohol content in blood using headspace method┆Drug solvent residue detection gas chromatograph┆Detection of Organophosphorus Pesticide Residues in Food by Gas Chromatography┆Detection of Organochlorine Pesticide Residues in Food by Gas Chromatography┆Detection of pesticide residues such as BHC and DDT in food using a chromatograph┆Natural gas component analysis gas chromatograph┆Liquefied petroleum gas component analysis gas chromatograph┆Analysis of Oxygen Compounds in Automotive Gasoline by Gas Chromatography┆Analysis of Aromatic Hydrocarbons in Automotive Gasoline by Gas Chromatography┆Analysis of Methanol in Methanol Gasoline by Gas Chromatography┆Gas chromatograph for biodiesel analysis┆Tobacco and tobacco packaging materialsVOCSDetection gas chromatograph┆Gas chromatograph for component detection of turpentine oil┆ Gas chromatograph for underground gas analysis in coal mines ┆ Gas chromatograph for detecting non methane total hydrocarbons in indoor environments ┆Sulfur containing/nitrogenous/Analysis of oxygen-containing compoundsgas chromatograph┆ Gas chromatograph for specialized analysis of food additives ┆Analysis of Organochlorine Pesticide Residuesgas chromatograph┆Analysis of Organophosphorus Pesticide Residuesgas chromatograph┆ Tar component analysis gas chromatograph ┆ Alcohol ether analysis gas chromatograph in gasoline ┆ Industrial phenolic compound analysis gas chromatograph ┆ Acetic acid and acetic anhydride analysis gas chromatograph ┆ Fatty acid methyl ester analysis gas chromatograph ┆Detection of solvent residues in vegetable oilgas chromatograph Detection of solvent residues in printing and packaging by gas chromatograph ∨ Analysis of pharmaceutical intermediates by gas chromatograph ∨ Detection of No. 6 solvent in vegetable oil by gas chromatograph ∨ Plasticizer detection in Baijiu by gas chromatograph ∨ Analysis of edible alcohol by gas chromatograph ∨ Detection of harmful and toxic gases in indoor environment by gas chromatograph ∨ Detection of trace gases in transformer insulating oil by gas chromatograph ∨Online automatic gas analysis dedicated gas chromatograph┊Helium ion high-purity gas analysis dedicated gas chromatograph┆ Fully automatic microcomputer reverse controlgas chromatograph┆ New generation fullEPCControl gas chromatograph
effectiveLiquid chromatograph:
twoMeta gradient effective liquid chromatography┆Milk and milk productsDetection and analysis liquid chromatography instrument┆ Traditional Chinese Medicine TestingEffective liquid chromatography instrument┊High pressure gradient liquid chromatography│Economical, practical and effective liquid chromatography instrument┆feedTesting specificeffectiveLiquid chromatograph┆Special liquid chromatography instrument for analysis of arachidonic acid in honey┆Special liquid chromatography instrument for paint and coating analysis┆Special liquid chromatography instrument for drug and pesticide residues┆ Vitamin detection in feed by liquid chromatography ┆ Traditional Chinese medicine decoction piece detection by liquid chromatography
The company's service advantages:
1. The technical indicators of the company's products strictly comply with the requirements of technical documents, and the product quality meets the requirements of relevant national standards.
2. The product is installed, debugged, and trained by technical personnel or provided with free telephone guidance.
3. After the product is accepted as qualified, our company guarantees free maintenance during the one-year warranty period, except for human damage factors; Lifetime maintenance of equipment, with only cost charges for vulnerable parts, free technical support, and discounted accessory supply.
4. The company's after-sales service engineers have received training in chemical analysis, instrument repair, and maintenance. They can maintain and repair various components to ensure that your instrument runs smoothly and can solve your problems quickly.
5. Timely telephone support - troubleshooting experts answer your calls and provide timely solutions to problems.
6. * * * * Service - Effective and high-quality pre-sales and after-sales services distributed within * * * *.
7. Flexible and fast response time - providing timely phone guidance or on-site problem-solving within 72 hours after telephone repair.
8. 24-hour uninterrupted online instrument problem solving.
9. There are free and irregular chromatography training courses every year. The content includes chromatographic principles, analysis, applications, technical instrument operation, and assistance in troubleshooting and maintenance.For more detailed product information, please call 0632-5080618/orwww.lcsepuUnderstand consultation.
The company is the earliest in ChinaIntegrated development and salesOne of several manufacturers of gas chromatographs,The name 'Lunan Chromatography Base' comes from this. Company ProductsExcellent performanceStableReliable, it is a domestic chromatographyThe Influence of the WorldStable brand. For decades, and salesLu Chuang'sbrandGCSeries gas chromatographs andLCSeries liquid chromatography instrumentSpread all over * * * *.It is widely used in health and epidemic prevention, food * *, environmental detection, quality supervision, petrochemical industry, fine chemical industry, coal mine * *, pesticide, pharmacy, commodity inspection, power, Baijiu, mine and other systems, as well as scientific research institutions, colleges and universities.
Lu ChuangThe chromatographic analysis laboratory provides free analysis methods and operational training for you.