STE
Control, protection, and isolation transformers
PRI 230 – 400 Vac, SEC 24 – 230 Vac, 63 – 2.500 VA, Elastic terminal
General data
Measurement power: 63-2.500 VA
Efficiency up to 95%
The maximum ambient temperature is 40 ° C
Insulation material grade B
Measure the output voltage of 24-230 Vac
Measure input voltage 230-400 Vac
Protection level IP 00
advantage
Good corrosion resistance and minimal noise ensured through vacuum infiltration
Reduce impulse current
Set ± 5% tap on the input end for voltage regulation
Compact mechanism achieves high power for each flow rate
Use elastic terminals for quick installation
Touch protection for wiring terminals, compliant with UVV BGV A3 requirements
Convenient fixation using sturdy metal support angle iron with long holes
DIN rail clamp is used below 250VA
standard
Control transformers comply with VDE 0570 Part 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
license
UL 5085-1/-2, CSA 22.2 No.66
application
As an isolation transformer used for safe electrical isolation of input and output terminals. This transformer is suitable for the construction of protective isolation devices and protective measures that comply with VDE 0100 requirements.
As a control transformer used for electrical isolation of input and output terminals. By design, the transformer is suitable for power supply to control devices that comply with VDE 0113 requirements.
As a protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.
2.500 VA
Product specification sheet download
Control, protection, and isolation transformers
PRI 230 – 400 Vac, SEC 24 – 230 Vac, 63 – 2.500 VA, Elastic terminal
General data
Measurement power: 63-2.500 VA
Efficiency up to 95%
The maximum ambient temperature is 40 ° C
Insulation material grade B
Measure the output voltage of 24-230 Vac
Measure input voltage 230-400 Vac
Protection level IP 00
advantage
Good corrosion resistance and minimal noise ensured through vacuum infiltration
Reduce impulse current
Set ± 5% tap on the input end for voltage regulation
Compact mechanism achieves high power for each flow rate
Use elastic terminals for quick installation
Touch protection for wiring terminals, compliant with UVV BGV A3 requirements
Convenient fixation using sturdy metal support angle iron with long holes
DIN rail clamp is used below 250VA
standard
Control transformers comply with VDE 0570 Part 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
license
UL 5085-1/-2, CSA 22.2 No.66
application
As an isolation transformer used for safe electrical isolation of input and output terminals. This transformer is suitable for the construction of protective isolation devices and protective measures that comply with VDE 0100 requirements.
As a control transformer used for electrical isolation of input and output terminals. By design, the transformer is suitable for power supply to control devices that comply with VDE 0113 requirements.
As a protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.
| variant | Measure input voltage | Measure output voltage | measured power |
| VDE (DB cos phi=1) | STE 63/23/24 | 230 Vac | 24 Vac |
| 63 VA | STE 63/4/24 | 400 Vac | 24 Vac |
| 63 VA | STE 63/4/23 | 400 Vac | 230 Vac |
| 63 VA | STE 100/23/24 | 230 Vac | 24 Vac |
| 100 VA | STE 100/4/23 | 400 Vac | 230 Vac |
| 100 VA | STE 160/23/24 | 230 Vac | 24 Vac |
| 160 VA | STE 160/4/23 | 400 Vac | 230 Vac |
| 160 VA | STE 250/23/24 | 230 Vac | 24 Vac |
| 250 VA | STE 250/4/24 | 400 Vac | 24 Vac |
| 250 VA | STE 250/4/23 | 400 Vac | 230 Vac |
| 250 VA | STE 320/23/24 | 230 Vac | 24 Vac |
| 320 VA | STE 320/4/23 | 400 Vac | 230 Vac |
| 320 VA | STE 400/23/24 | 230 Vac | 24 Vac |
| 400 VA | STE 400/4/23 | 400 Vac | 230 Vac |
| 400 VA | STE 500/23/24 | 230 Vac | 24 Vac |
| 500 VA | STE 500/4/24 | 400 Vac | 24 Vac |
| 500 VA | STE 500/4/23 | 400 Vac | 230 Vac |
| 500 VA | STE 630/4/23 | 400 Vac | 230 Vac |
| 630 VA | STE 800/4/23 | 400 Vac | 230 Vac |
| 800 VA | STE 1000/4/23 | 400 Vac | 230 Vac |
| 1.000 VA | STE 1600/4/23 | 400 Vac | 230 Vac |
| 1.600 VA | STE 2000/4/23 | 400 Vac | 230 Vac |
| 2.000 VA | STE 2500/4/23 | 400 Vac | 230 Vac |
2.500 VA