Jinan Shangdi Electronic Technology Co., Ltd
Home>Products>Precision Alloy/Ore Analyzer - Composition Quantification 1
Precision Alloy/Ore Analyzer - Composition Quantification 1
Alloy/ore composition analyzer (precise quantification), also known as graphite flame integrated atomic absorption spectrophotometer. Introduction: It
Product details
Alloy/Ore Composition Analyzer (Accurate Quantification), also known as Graphite Flame Integrated Atomic Absorption Spectrophotometer Introduction: It is a precision instrument mainly used to detect the trace/trace metal element content in various substances of alloy materials and ores. It can detect the following elements: lithium, sodium, magnesium, aluminum, silicon, potassium, calcium, chromium (g è), manganese, iron, cobalt, nickel, copper, zinc, arsenic, selenium (x ī), silver, cadmium, indium, tin, antimony, platinum, gold, lead and more. The integrated flame atomizer and graphite furnace atomizer are designed with a detection limit of PPB level (one billionth content)

SDA-100SFG (Standard Flame Graphite Furnace Type 1)Atomic absorption spectrophotometer

Introduction: It is a precision instrument mainly used to detect the content of trace/trace metal elements in various substances. It can detect more than 70 types of elements, including lead, manganese, iron, cobalt, nickel, copper, zinc, arsenic, selenium (x ī), silver, cadmium, indium, tin, antimony, platinum, gold, lithium, sodium, magnesium, aluminum, silicon, potassium, calcium, chromium (g è), etc. The integrated flame atomizer and graphite furnace atomizer are designed with a detection limit of PPB level (one billionth content), fully automatic computer control and data processing, including air acetylene flame method, graphite furnace method, hydride generator atomic absorption method, oxygen enriched air acetylene flame method; A hydride generator can be added to expand the detection range.

1、 Performance indicators
1. Optical system
Automatic adjustment of wavelength range 190nm-900nm
Grating engraved line density 1800 lines
Monochromator aberration correction Czerny Turner type monochromator
Spectral bandwidth of 0.1, 0.2, 0.4, 1.0, and 2.0nm, with multiple automatic switching modes
Wavelength accuracy ± 0.20nm
Wavelength repeatability of 0.1nm
Baseline drift static 0.005A/30min dynamic 0.008A/30min
Detector wide spectral range photomultiplier tube
The resolution can distinguish the dual lines of 279.5nm and 279.8nm in the manganese lamp, and the energy of the valley between the two spectral lines should be less than 20%


2. Light source system
Lamp holder 3 lamp holder
Lamp power supply method: 400Hz square wave pulse
Lamp current regulation range 0-10mA average current
3. Atomization system
Flame analysis method
Detection limit (Cu) 0.006 μ g/ml
Burner 100mm all titanium metal burner
Precision RSD ≤ 1%
Spray metal sheathed high-efficiency glass spray
Corrosion resistant all plastic atomization chamber
The safety measures have multiple automatic safety protection functions, including acetylene leakage alarm and automatic shutdown system
Flameless (graphite furnace) analysis method
Detection limit (Cd) ≤ 4pg

4. Flame analysis method and measurement method

Air acetylene flame method, hydride generator atomic absorption method
The concentration calculation method automatically fits the working curve, automatically corrects sensitivity, and calculates concentration and content.
Repeat measurements 1 to 99 times, automatically calculate the mean, content, standard deviation, and relative standard deviation.
Print test data or final analysis report as a result. The results can be exported as an Excel worksheet.

Previous: Rapid Alloy/Ore Detector - Quantitative

Next article: Handheld alloy/ore analyzer
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!