Instrument Introduction
1. The general thermal cracking temperature is 500-600 ° C, so it cannot be operated by handheld methods. Therefore, previous thermal cracking equipment could only be fixed and used on GC or GC/MS. Compared with this, the JAI portable Curie point pyrolysis instrument does not generate excess heat due to the use of Curie point heating, and does not burn the operator when introducing gas samples.
The miniaturization of mechanical components and the highly integrated development of electronic components have made it possible to miniaturize the JAI portable Curie point pyrolysis instrument.
3. Eliminated the installation work of thermal cracking equipment
When installing a general thermal cracking device on GC or GC/MS, the vacuum system should be stopped first and the carrier gas flow path should be changed. After installation, the vacuum system should be restarted until it reaches normal values, which takes at least 3 to 6 hours. But the JAI portable Curie point pyrolysis instrument eliminates these tedious processes and can directly vaporize solid samples and inject them into the injection port of GC or GC/MS. This is an unprecedented global first thermal cracking device.
4. Compatible with other types of accessories
Even if the GC/MS is equipped with accessories such as an automatic sampler, it does not need to be removed. The JAI Curie point sampler can directly inject samples from other injection ports.
5. Enable multiple injection methods.
main features
1. Solid, liquid, solid degassed substances, and volatile compounds can be directly injected into the injection port of a gas chromatograph or gas chromatography-mass spectrometer, just as simple as injecting liquid samples with a microinjector.
2. It eliminates the tedious process of installing a thermal cracking instrument in the past. The operator can directly insert the probe into the injection port of GC/MS for thermal cracking GC injection.
3. After each injection of the sample, cleaning or replacing the injection needle is simple and easy, and will not cause contamination of the sample tube or GC flow path.
4. Easy to carry, the standard 5L gas cylinder (JCI22 type) can be used in conjunction with a portable GC for easy operation at any time.
Technical Parameter
JCI-22 Technical Parameters
|
|
Injector section
|
|
Heating method
|
Curie point heating method
|
Sample heating
|
Hot foil heating (160-1040 ℃)
|
System preheating
|
150℃
|
Sample tube
|
Quartz tube (outer diameter 6mm, length 42mm)
|
syringe
|
JCI dedicated injection needle (outer diameter 0.47mm, length 36mm)
|
The signal line
|
2m
|
size
|
Outer diameter 35 × 180mm
|
weight
|
110g
|
controller
|
|
High frequency power supply
|
48 W、600kHZ
|
output signal
|
GC start signal
|
Inject helium gas
|
Provide helium gas with a pressure of over 0.5Mpa from a 5L clamp container bottle
|
size
|
150(W)×200(H)×320(D)mm
|
quality
|
8kg
|
power supply
|
AC85-240V 500VA(MAX)
|
JCI-22S Technical Parameters
|
|
Carrier gas (He)
|
Supply helium gas with a pressure above 0.5Mpa
|