Mettler Inlab Viscous Pro ISMpH electrode
Mettler Toledo
name:Three in one high viscosity sample pH electrode
model: Inlab Viscous Pro-ISM
InLab Viscous Pro-ISM
Composite pH electrode with built-in temperature probe
Composite pH electrode, glass electrode rod material, built-in temperature probe, SteadyForce ™ Pre pressurization system and Multiplain ™ The connector. Used for measuring viscous samples, such as cosmetics, paints, and adhesives.
51343151, three in one high viscosity sample pH electrode (0-14PH, 0-130 ℃), made of glass material, multi pin connector (requires an additional 1.2-meter cable 30281896, with 3-meter and 5-meter options available), equipped with SteadyForceTm system. Suitable for measuring various viscous samples, such as various cream cosmetics, shampoo, shower gel, hair dye, cheese, jam, paint and coatings, etc
Specifications - InLab Viscous Pro ISM
measuring range | pH 0 – 14 |
temperature range | 0 °C – 130 °C |
Connector | MultiPin ™ |
Contact type | ceramics |
Shaft material | Glass |
Sensor type | Composite electrode |
Electrode rod length | 40 mm |
Electrode rod diameter | 6 mm |
parameter | pH |
Reference system | SteadyForce ™ |
Reference electrolyte | FRISCOLYT-C ® |
Glass film | HA |
Membrane impedance (25 ° C) | < 600 MΩ |
ISM | Yes |
Temperature probe | NTC 30 kΩ |
Used for portable instruments | nothing |
No maintenance required | have |
Signal type | simulation |
sample | Lotion; Adhesive sample |
Material number (s) | 51343151 |
more:Mettler Inlab Viscous Pro ISMpH electrode
classification | model | Order number | Explanation |
Only ISM is used for existing Seven series instruments |
Inlab Expert Pro-ISM | 30014096 | Three in one conventional sample pH electrode (0-14pH, 0-100 ℃), PEEK material, BNC/Inch interface, including 1.2m cable, with Argenthal system |
Inlab Expert Pro-2m-ISM | 51343102 | Three in one conventional sample pH electrode (0-14pH, 0-100 ℃), PEEK material, BNC/Inch interface, including 2m cable, with Argenthal system | |
Inlab Routine Pro-ISM | 51344055 | Three in one strong acid and strong alkali pH electrode (0-14PH, 0-100 ℃), made of glass material, multi pin connector (requires additional 1.2-meter cable 30281896, with 3-meter and 5-meter options available), equipped with Argenthal system and silver ion capture trap. Suitable for measuring strong acid and alkali samples, high-temperature samples, biological samples, etc | |
Inlab Solids Pro-ISM | 51344155 | Three in one solid/semi-solid sample pH electrode (1-11pH, 0-80 ℃), multi pin connector (requires additional 1.2-meter cable 30281896, with optional 3-meter and 5-meter options), equipped with Argenthal system. Suitable for measuring solid samples such as cheese, meat, fish, soil, etc | |
Inlab Power Pro-ISM | 51344211 | Three in one pre pressurized pH electrode (0-12pH, 0-100 ℃), multi pin connector (requires additional 1.2-meter cable 30281896, with 3-meter and 5-meter options available), equipped with SteadyForceTm system, suitable for measuring high-temperature samples as well as various viscous, suspended, and oily samples such as glue, paint, jam, cream, milk, soil suspension, emulsion, etc | |
Inlab Viscous Pro-ISM | 51343151 | Three in one high viscosity sample pH electrode (0-14PH, 0-130 ℃), made of glass material, multi pin connector (requires additional 1.2-meter cable 30281896, with 3-meter and 5-meter options available), equipped with SteadyForceTm system. Suitable for measuring various viscous samples, such as various cream cosmetics, shampoo, shower gel, hair dye, cheese, jam, paint and coatings, etc | |
InLab Surface-Pro-ISM | 30249570 | Three in one planar sample electrode (1-11pH, 0-50 ℃), made of glass material, multi pin connector (requires additional 1.2-meter cable 30281896, with 3-meter and 5-meter options available), equipped with Argenthal system and silver ion trap. Suitable for surface pH measurement of paper, textiles, skin, wall coatings, etc | |
Inlab Max Pro-ISM | 30248830 | Three in one low ion concentration sample pH electrode (0-14PH, 0-100 ℃), made of glass material, with a multi pin connector (requires an additional 1.2-meter cable 30281896, with 3-meter and 5-meter options available), equipped with Argenthal system and silver ion capture trap. Suitable for measuring low ion concentration solutions or viscous solutions, such as tap water, beer, jam, dairy products, sugar water, paint coatings, etc | |
Inlab Science Pro-ISM | 51344072 | Three in one low ion concentration sample pH electrode (0-12pH, 0-100 ℃), made of glass material, multi pin connector (requires an additional 1.2-meter cable 30281896, with optional 3-meter and 5-meter options), equipped with Argenthal system and silver ion capture trap. Suitable for measuring low ion concentration solutions or viscous solutions, such as tap water, beer, jam, dairy products, sugar water, paint coatings, etc | |
Inlab Cool Pro-ISM | 30247850 | Three in one low-temperature pH electrode (1-11pH, 30-80 ℃), made of glass material, multi pin connector (requires additional 1.2-meter cable 30281896, with 3-meter and 5-meter options available), equipped with Argenthal system and silver ion trap. Suitable for pH measurement of pure water, ultrapure water, and low-temperature samples | |
Inlab Pure Pro-ISM | 51344172 | Three in one ultrapure water electrode (1-11pH, 0-80 ℃), made of glass material, multi pin connector (requires additional 1.2-meter cable 30281896, with 3-meter and 5-meter options available), equipped with Argenthal system and silver ion trap. Suitable for pH measurement of ultrapure water such as boiler water, injection water, and drinking water | |
Inlab Micro Pro-ISM | 51344163 | Micro sample electrode (0-14PH, 0-80 ℃), made of glass material, multi pin connector (requires additional 1.2-meter cable 30281896, with 3-meter and 5-meter options available), equipped with Argenthal system and silver ion trap. 5mm diameter ultrafine electrode, suitable for measuring trace samples in centrifuge tubes and PCR tubes | |
Inlab Ultra-Micro-ISM | 30244732 | Ultra micro sample electrode (0-11pH, 0-80 ℃), made of glass material, multi needle connector (requires additional 1.2-meter cable 30281896, with 3-meter and 5-meter options), 3mm diameter ultra-fine electrode, capable of measuring extremely small volume samples as low as 15uL, suitable for measuring micro samples in centrifuge tubes and PCR tubes | |
InLab 731-ISM | 30014092 | Conductive electrode (10uS/cm-1000mS/cm, 0-100 ℃), made of epoxy resin material, containing 1m cable, suitable for measuring high conductivity aqueous solutions | |
InLab 731-ISM-2m | 30014093 | Conductive electrode (10uS/cm-1000mS/cm, 0-100 ℃), made of epoxy resin material, containing 2m cable, suitable for measuring high conductivity aqueous solutions | |
InLab 741-ISM electrode | 30014094 | Ultra pure water conductivity electrode (0.001-500uS/cm, 0-100 ℃), made of stainless steel material, including 1m cable, suitable for measuring the conductivity of pure water and ultra pure water (ultra pure water measurement requires flow channel 51302257) | |
InLab OptiOx-ISM | 51344621 | InLab OptiOx ISM IP67 optical dissolved oxygen sensor (0-500%, 0-50mg/L, 0-50 ℃), with 1.8 cable, only used for SG9 SG98、SevenExcellence | |
InLab OptiOx-ISM-5m | 51344622 | InLab OptiOx ISM-5m IP67 optical dissolved oxygen sensor (0-500%, 0-50mg/L, 0-50 ℃), including 5m cable, only used for SG9 SG98、SevenExcellence | |
InLab OptiOx-ISM-10m | 51344623 | InLab OptiOx ISM-10m IP67 optical dissolved oxygen sensor (0-500%, 0-50mg/L, 0-50 ℃), including 10m cable, only used for SG9 SG98、SevenExcellence | |
OptiOx measurement module | 51344630 | OptiOx dissolved oxygen measurement module, built-in countdown clock, can indicate service life | |
OptiOx calibration tube | 51344631 | OptiOx calibration tube, used for InLab OptiOx calibration and storage | |
OptiOx protective cover | 51344632 | OptiOx protective cover (stainless steel) | |
OptiOx BOD adapter | 51344633 | OptiOx BOD adapter for BOD culture bottles | |
OptiOx uPlace adapter | 30246619 | OptiOx uPlace adapter for uPlace brackets | |
ISM digital electrode | Inlab Smart Pro ISM PH Electrode | 30027775 | Digital ISM intelligent PH electrode (0-14PH, 0-100 ℃), with electrode diagnostic function, made of glass material, K8SD interface (requires additional cable ME30027776), built-in temperature probe, only used for SevenCompact and SevenExcellence series |
Inlab Trace Conductivity Electrode | 30014097 | Digital ISM high-precision conductivity electrode (0.001-1000uS/cm, 0-100 ℃), made of titanium material, PT1000 temperature probe, including 1.8m cable, used for measuring pure water and ultrapure water conductivity in S230 and SevenExcellence series (ultrapure water measurement requires flow channel ME30014098) | |
InLab Trace dedicated flow pool | 30014098 | Polypropylene flow cell, used in conjunction with InLab Trace electrode to measure the conductivity of ultrapure water | |
Inlab Trace package (including electrodes and flow cell) | 30014099 | Digital ISM high-precision conductivity electrode (0.001-1000uS/cm, 0-100 ℃), made of titanium material, PT1000 temperature probe, including 1.8m cable, polypropylene flow cell, used for measuring pure water and ultrapure water conductivity in S230 and SevenExcellence series | |
InLab Trace Flow Pool Special Connection Tube | 30115486 | InLab Trace Flow Pool Special Connection Tube (List price is per meter, please place an order based on the required length in meters) |