LWGY Turbine Flow Sensor
Turbine flow ratesensorIt does not have on-site display function and only transmits the flow signal in the form of three wire voltage pulses for remote output. Power supply+12VDC or+24VDC, remote transmission distance
Basic parameters and technical performance:
Instrument caliber and connection method |
4. 6, 10, 15, 20, 25, 32, 40 are connected by threads (15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200 are connected by flanges |
accuracy class |
± 1% R, ± 0.5% R, ± 0.2% R (to be customized) |
Range ratio |
1:10; 1:15; 1:20 |
Instrument material |
304 stainless steel, 316 (L) stainless steel, etc |
Temperature of the tested medium (℃) |
-20~+120℃ |
environmental condition |
Temperature -10~+55 ℃, relative humidity 5%~90%, atmospheric pressure 86~106Kpa |
output signal |
Sensor: Pulse frequency signal, low level ≤ 0.8V, high level ≥ 8V Transmitter: two-wire 4-20mADC current signal |
power supply |
Sensor:+12VDC,+24VDC (optional) Transmitter:+24VDC On site display type: The instrument comes with a 3.2V lithium battery |
Signal transmission line |
STVPV3 × 0.3 (three wire system), 2 × 0.3 (two wire system) |
Distance |
≤1000m |
Signal line interface |
Basic type: Hausman connector, explosion-proof type: internal thread M20 × 1.5 |
Explosion proof grade |
Basic Type: Non Explosion proof Product, Explosion proof Type: ExdIIBT6 |
protection grade |
IP65 |
Measurement range and work pressure
Instrument caliber (mm) |
Normal flow range (m3/h) |
Expand traffic range (m3/h) |
Default installation method and voltage rating |
Optional installation methods and default voltage rating |
Specially designed pressure resistance level (MPa) |
DN4 |
0.04~0.25 |
0.04~0.4 |
Threaded installation, 6.3Mpa |
Flange installation, 2.5MPa |
12. 16, 25 |
DN6 |
0.1~0.6 |
0.06~0.6 |
Threaded installation, 6.3Mpa |
Flange installation, 2.5MPa |
12. 16, 25 |
DN10 |
0.2~1.2 |
0.15~1.5 |
Threaded installation, 6.3Mpa |
Flange installation, 2.5MPa |
12. 16, 25 |
DN15 |
0.6~6 |
0.4~8 |
Threaded installation, 6.3Mpa |
Flange installation, 2.5MPa |
4.0, 6.3, 12, 16, 25 |
DN20 |
0.8~8 |
0.45~9 |
Threaded installation, 6.3Mpa |
Flange installation, 2.5MPa |
4.0, 6.3, 12, 16, 25 |
DN25 |
1~10 |
0.5~10 |
Threaded installation, 6.3Mpa |
Flange installation, 2.5MPa |
4.0, 6.3, 12, 16, 25 |
DN32 |
1.5~15 |
0.8~15 |
Threaded installation, 6.3Mpa |
Flange installation, 2.5MPa |
4.0, 6.3, 12, 16, 25 |
DN40 |
2~20 |
1~20 |
Threaded installation, 6.3Mpa |
Flange installation, 2.5MPa |
4.0, 6.3, 12, 16, 25 |
DN50 |
4~40 |
2~40 |
Flange installation, 2.5Mpa |
Threaded connection, 6.3MPa |
4.0, 6.3, 12, 16, 25 |
DN65 |
7~70 |
4~70 |
Flange installation, 1.6Mpa |
Threaded connection, 6.3MPa |
4.0, 6.3, 12, 16, 25 |
DN80 |
10~100 |
5~100 |
Flange installation, 1.6Mpa |
Threaded connection, 6.3MPa |
4.0, 6.3, 12, 16, 25 |
DN100 |
20~200 |
10~200 |
Flange installation, 1.6Mpa |
4.0, 6.3, 12, 16, 25 |
|
DN125 |
25~250 |
13~250 |
Flange installation, 1.6Mpa |
2.5, 4.0, 6.3, 12, 16 |
|
DN150 |
30~300 |
15~300 |
Flange installation, 1.6Mpa |
2.5, 4.0, 6.3, 12, 16 |
|
DN200 |
80~800 |
40~800 |
Flange installation, 1.6Mpa |
2.5, 4.0, 6.3, 12, 16 |
Selection of Turbine Flow MetertypeAnd specifications:
model |
describe |
|||||||
LWGY |
Basic type, powered by+5-24DCV, without on-site display |
|||||||
LWGB |
4-20mA two-wire current output, without on-site display |
|||||||
LWY |
Battery powered on-site display type |
|||||||
LWYC |
On site display/4~20mA two-wire current output |
|||||||
state-owned call open up or clear out by poking or jabbing footpath |
4 |
4mm, The standard range is 0.04-0.25m3/h, and the wide range is 0.04-0.4m3/h |
||||||
6 |
6mm, The standard range is 0.1-0.6m3/h, and the width measuring wheel is 0.06-0.6m3/h |
|||||||
10 |
10mm, The standard range is 0.2-1.2m3/h, and the wide range is 0.15-1.5m3/h |
|||||||
15 |
15mm, The standard range is 0.6-6m3/h, and the wide range is 0.4-8m3/h |
|||||||
20 |
20mm, The standard range is 0.8-8m3/h, and the wide range is 0.4-8m3/h |
|||||||
25 |
25mm, The standard range is 1-10m3/h, and the wide range is 0.5-10m3/h |
|||||||
32 |
32mm, The standard range is 1.5-15m3/h, and the wide range is 0.8-15m3/h |
|||||||
40 |
40mm, The standard range is 2-20m3/h, and the wide range is 1-20m3/h |
|||||||
50 |
50mm, The standard range is 4-40m3/h, and the wide range is 2-40m3/h |
|||||||
65 |
65mm, The standard range is 7-70m3/h, and the wide range is 4-70m3/h |
|||||||
80 |
80mm, The standard range is 10-100m3/h, and the wide range is 5-100m3/h |
|||||||
100 |
100mm, The standard range is 20-200m3/h, and the wide range is 10-200m3/h |
|||||||
125 |
125mm, The standard range is 25-250m3/h, and the wide range is 13-250m3/h |
|||||||
150 |
150mm, The standard range is 30-300m3/h, and the wide range is 15-300m3/h |
|||||||
200 |
200mm, The standard range is 80-800m3/h, and the wide range is 40-800m3/h |
|||||||
communication |
C1 |
On site display/RS485 communication protocol |
||||||
C2 |
On site display/ART communication protocol |
|||||||
accuracy class |
05 |
Accuracy level 0.5 |
||||||
10 |
Accuracy level 1.0 |
|||||||
turbine type |
W |
Wide range turbine |
||||||
S |
Standard turbine |
|||||||
material |
S |
304 stainless steel |
||||||
L |
316 (L) stainless steel |
|||||||
P |
Rubber and Plastic |
|||||||
explosion-proof |
Unmarked, non explosion proof type |
|||||||
E |
Explosion proof type (Exm Ⅱ CT6 or Exd Ⅱ BT6) |
|||||||
pressure rating |
N |
Conventional (refer to measurement range and working pressure gauge) |
Note: DN15 to DN40 are usually threaded connections. If you want to use flange connections, please add "(FL)" after "nominal diameter". For example, if you choose a flange connected explosion-proof turbine flowmeter to measure diesel, the pipeline is DN40, and the current signal needs to be displayed and transmitted remotely on site, with an accuracy of 0.5 level, made of 304 stainless steel material, and the instrument pressure resistance is 16MPa. The measurement range is the standard range, and the product model should be:LWGC-4005S-SEN16