1Standard volume ratio:The ratio of component A, component B, and component C can be set and adjusted on the human-machine interface. The adjustment range is A: B: C (0.1-11): 1: (0.01-0.1) (C is the third agent added, usually a color paste, which is an optional component)
2Maximum flow rate:5L/min, When the viscosity is 100000pps, A+B+C)
3Mixing methodStatic mixer
4Maximum fluid pressure:30MPa
5Power requirements:380V,3KW, three-phase four-wire system
6Compressed air:3bar-10bar
7. The flow rate closed-loop output mode or pressure closed-loop output mode can be set. When one mode is selected, the design of the other parameter is the theoretical calculation value. For example, when selecting the flow closed-loop output mode and setting the flow rate of A to 2L/min, the pressure parameter setting is the calculated value.
8Air inlet size:Rc3/4
9. Flow detection: flow sensor, measurement accuracy ± 1%
10Feeding pipe diameter: Diameter 20mm
11Quantitative output:The output quantity can be pre-set and can be divided into four stages, with each stage's output pressure and flow rate set separately. The feeding system can adjust and output the raw materials according to the data set by the customer. (Note: The output flow rate is theoretical calculation data, and the actual flow rate can be displayed on the monitoring screen.)
12Maximum output per injection:400kg (when the specification of the raw material barrel is 200kg/barrel)
13Ratio accuracy: ± 1% (volume ratio)
14Adapt to the viscosity of raw materials:>=800000cps
15Equipment weight:700kg
16Equipment size:1415x1200x1625 (length x width x height)