Type: Characteristics: ● Simple structure: The components are firmly connected, highly reliable, and require minimal maintenance. Generally, no mainte
Product details
-
Working voltage: 20…30VDC power waste: < 80mA Measurement accuracy: ± 3% of the maximum measurement range Repetition accuracy: ± 1% of the maximum measurement range Protection level: IP67 Digital Communication: Isolation RS485, MODBUS RTU communication protocol, 9600 8N1 format output 0... 10V output: Negative load minimum 500 Ω 0... 20mA output: Maximum negative load of 500 Ω 4... 20mA output: Maximum negative load of 500 Ω Switching output: PNP (NO/NC switchable) Load current: Maximum 200mA (with short circuit protection) Switch point setting: 5... 95% adjustable Applicable working conditions Working environment temperature range: -20... 60 ℃ (ordinary type) -20... 200 ℃ (high temperature heat dissipation type) -70... 230 ℃ (amplifier split type) Medium temperature range: 0... 70 ℃ (ordinary type) -20... 200 ℃ (high temperature heat dissipation type) -70... 230 ℃ (amplifier split type) Storage temperature range: -25…80℃ Applicable medium range: Solid, liquid, or slurry with a measurable dielectric constant greater than 1.8 Maximum pressure of medium: 0.3MPa Dielectric constant of the medium: >1.8 Capacitance measurement range: Maximum: 0... 3.3nF, Minimum: 0... 3.3pF Material specifications Electrical interface: M12 * 1 aviation connector Installation method: G1, G1-1/2, G1-1/4 Φ 50.5 chuck Flange specifications (such as DN50) Aluminum, stainless steel 1.4301 (304) Shell material: The panel is made of PC plastic Outer material of probe rod: PTFE or PEEK Probe length: 200mm... 3000mm, PEEK maximum 300mm