VIP member
KFGM44 digital gas mass flowmeter
Type: Micro gas mass flowmeter Features: ● Adopting micro electromechanical system (MEMS) flow sensing chip, the sensor has high precision, high sensi
Product details
-
Accuracy level: ±1.5% Response time (ms): 100ms Maximum work pressure: 16bar Working power supply: 15V…24V 100mA Output method: 4…20mA, Communication (optional) Display: Instantaneous flow, cumulative flow Medium temperature: -10…55℃ Humidity: <95% RH (no frosting, no freezing) Process connection: G1/2, G3/4 or customer bulk customization Overall power consumption: ≤2.4W Communication method: RS485 (Modbus protocol) Calibration conditions: Air (20 ℃, 101.325kPa)
-
KFGM44- Digital gas mass flowmeter code Nominal caliber Range L/min Range ML/min Process connection pressure resistance DN8 0.05…1 50…1000 G1/4 ≤10bar DN8 0.05…3 50…3000 G1/4 ≤10bar DN8 0.1…10 100…10000 G1/4 ≤10bar DN10 0.3…30 300…30000 G3/8 ≤10bar DN10 0.5…50 500…50000 G3/8 ≤10bar DN10 0.7…70 700…70000 G3/8 ≤10bar DN10 2.3…230 2300…230000 G3/8 ≤10bar DN15 2…200 2000…200000 G1/2 ≤15bar DN15 3…300 3000…300000 G1/2 ≤15bar DN20 6…600 6000…600000 G3/4 ≤15bar DN20 8…800 8000…800000 G3/4 ≤15bar DN25 20…2000 20000…2000000 G1 ≤15bar Output signal or communication 4... 20mA current rs485 communication RS485 communication+4... 20mA current Sensor material AlZnMgCu1.5/3.4365 aluminum alloy (7075 aviation aluminum) Stainless steel 1.4301 (SUS304) Stainless steel 1.4571 (SUS316) power supply 24VDC ± 10% DC power supply accuracy class ±1.5% Special backup options Process connection: Vcr connector Process connection: Baota head connection Process connection: Card sleeve connection
Online inquiry