Principle, structure
The KAP20 pressure transmitter uses a flat membrane silicon piezoresistive isolation membrane oil filled core as the signal measuring element, and a signal processing circuit located inside the stainless steel housing converts the sensor signal into a standard output signal. Effectively prevent the problem of easily crystallized media blocking the pressure inlet.

characteristic
● Universal hygiene grade clamp chuck connection with a diameter of 50.4
● Wide measurement range from 0 to 100 bar
Stainless steel structure or cast aluminum explosion-proof structure
●IP65

application
Non corrosive gas and liquid pressure measurement for 316L stainless steel.
Applied in industries such as healthcare, biological products, and food hygiene.
Applied to the papermaking and chemical industry, wastewater level measurement, and beverage can pressure measurement.
Technical Parameter
Range: | 0~350mbar…100bar | ||||||||||||
Allow overload: | Less than or equal to 1.5 times the rated range | ||||||||||||
Pressure type: | Gauge pressure, absolute pressure | ||||||||||||
accuracy: | ± 0.25% (typical) ± 0.5% (maximum) | ||||||||||||
Long term stability: | ± 0.1% F.S/year (typical) ± 0.2% F.S/year (maximum) | ||||||||||||
Zero temperature drift: | ±0.03%F.S/℃(≤100KPa) ±0.02%F.S/℃(>100KPa) | ||||||||||||
Full temperature drift: | ±0.03%F.S/℃(≤100KPa) ±0.02%F.S/℃(>100KPa) | ||||||||||||
Working temperature: | -20℃~80℃ | ||||||||||||
Storage temperature: | -40℃~120℃ | ||||||||||||
Power supply: | ≥10KΩ(0..10V),≥5KΩ | ||||||||||||
Output signal: | ≤(UB-10)V/ 0.02A (4~20mA) | ||||||||||||
Pressure interface: | Clamp disc type | ||||||||||||
Shell material: | Stainless steel or cast aluminum | ||||||||||||
Membrane material: | Stainless steel 1.4435 (316L) | ||||||||||||
O-ring seal: | VITON | ||||||||||||
Cable: | polyethylene | ||||||||||||
Insulation resistance: | 100MΩ 100VDC | ||||||||||||
Shell protection level: | IP65 |
Electrical wiring diagram

dimension


Relative pressure |
absolute pressure |
|
|
Model Selection Table
KAP20- | Sanitary flat membrane pressure transmitter | ||||||
measuring range | |||||||
Gauge pressure (see range code table for range) (* This is a standard selection) | |||||||
Absolute pressure (see range code table for range) | |||||||
power supply | |||||||
10~30VDC | |||||||
output signal | |||||||
4~20mADC | |||||||
1~5VDC | |||||||
Threaded interface | |||||||
Clamp connection (Ø 50.4) | |||||||
Electrical connection | |||||||
Husman terminal connector (DIN43650) | |||||||
Explosion proof functional shell | |||||||
(Special alternative) VARIO | |||||||
LCD display unit | |||||||
Supporting installation of chuck and clamp fasteners | |||||||
The selection form for appeal does not include selection codes. If you need a code, please contact us or fill in your information |