Italy Hana HI991000 portable acidity meter
The Italian Hana HI991000 portable acidity meter has automatic temperature compensation. With the help of the HI7669AW temperature rod, it can automat
Product details
Product introduction of Italy Hana HI991000 portable acidity meter:

HI991000 portable acidity meter

  • Automatic temperature compensation, aided by the HI7669AW temperature rod, can automatically correct the impact of temperature on acidity and alkalinity
  • The simple and straightforward operation panel and easy to read display make the instrument easy to understand and operate
  • An accurate thermometer with an independent temperature probe can quickly sense the temperature of the solution being measured.
  • High precision resolution up to 0.1mV
  • Automatic buffer recognition * Simple automatic two-point calibration * 3-in-1 PH/mV/℃ tester
  • The sturdy and waterproof design of the ABS shell meets the IP167 international standard, providing complete protection for the instrument in harsh environments.
  • The characteristics of special graphic symbols and five sets of memory standard buffers can guide users to perform calibration steps step by step
  • Five standard buffer calibration points can be automatically or manually identified for calibration
  • The calibration results are stored in the memory of the microprocessor and can be retained even when turned off.
  • HI991000 portable acidity/ORP

Technical specifications of HI991000 portable acidity meter

Model number HI8424 HI991000
measuring range 0.00 to 14.00pH; 0.0 to ±399.9mV(ISE);
±400 to ±1999mV(ORP); 0.0 to 100.0℃
0.00 to 14.00pH
0.0 to 60.0℃
resolution 0.01pH;1mV(ISE); 1mV(ORP); 0.1℃ 0.01pH;0.1℃
accuracy ±0.01pH /±0.2mV(ISE); ±1mV(ORP)/ ±0.4℃ ±0.01pH;±0.5℃
EMC deviation ±0.02pH;±0.2mV(ISE); ±1mV(ORP); ±0.4℃ ±0.01pH;±1℃
Calibration method Automatic two-point calibration (pH7.01, 4.01, 10.01) Automatic three-point calibration
temperature compensation Automatic temperature compensation from 0 to 100 ℃ Automatic temperature compensation from 0 to 60 ℃
Zero point calibration ±1.0pH  
Slope calibration 70% to 108%  
Supporting electrode HI1230, HI1200 plastic electrodes H1291 electrode with temperature sensor (1 meter)
temperature probe HI7669AW one meter long line  
impedance 1012Ω  
Type 1×9V 4×1.5V AAA
environment 0 to 50 ℃, 95% RH 0 to 50℃; RH100%
Size/Weight 185×82×45mm / 520g 150×80×28mm /210g

Standard configuration of HI991000 portable acidity meter

HI8424 Host, HI123OB plastic electrode (including 1 meter), HI7669AW temperature probe, 9V battery
HI8424C Host, HI120OB plastic electrode (including 1 meter), HI7669AW temperature probe, 9V battery
HI8424CT Host, HI1200B plastic electrode (including 1 meter), 9V battery
HI8424P Host, HI123OB plastic electrode (including 1 meter), HI7669AW temperature probe, 9V battery, carrying case
HI8424PC Host, HI120OB plastic electrode (including 1 meter), HI7669AW temperature probe, 9V battery, carrying case
HI991000 Host, HI1291 electrode with amplification and ATC functions, 4 × 1.5V battery, hard carrying case

Accessories for purchasing HI991000 portable acidity meter

HI1230B Acidic composite plastic electrode (1 meter)
HI1230B/5 Acidic composite plastic electrode (5 meters)
HI1230B/10 Acidic composite plastic electrode (10 meters)
HI1200B Acidic composite plastic electrode
HI1300B PH composite plastic electrode (pure water measurement)
HI7669AW Temperature probe
HI2602 carrying case
HI1291 PH/℃ electrode with amplification function