When softCapsule machineWhen abnormal faults occur, it may result in incorrect "timing" of each cam (i.e. incorrect sequence of action for each cam). When making adjustments, please ensure that the movement of each mechanism does not interfere. The electric motor slows down and runs continuously through a reducer, while the filling turntable generates intermittent motion through the turntable indexing box. When it is necessary to adjust the "timing" of each cam (i.e. the time of each cam action), please use the handle to rotate the main motor shaft. When the filling turntable reaches a certain workstation, it changes from moving to stopping and continues for a period of time. During the period when the filling turntable stops moving, the following operations should be performed:
1) The cam used for distributing capsules in the first and second stations should send the capsules to the upper module port;
2) The cam that separates the bottle cap and capsule body through the vacuum separator on the second and second workstations should rise to the lower plane of the lower module, and the vacuum system should generate sufficient vacuum to allow the capsule to enter the capsule. Module and cover, separate body
3) The cam used to reject capsules that have not been separated at the sixth workstation should be raised to remove defective capsules;
4) The cam used to lock the filled capsules at the eighth workstation should be raised to lock the capsules;
5) The cam used to push out the finished product on the ninth workstation should be raised to push out the finished product.
After the interval period, the filling turntable begins to move to the next workstation. Please ensure that the movement of each mechanism does not interfere during the exercise. When interference occurs, you should check whether the cam action is too early or too late, and when the cam action is too early, loosen the fastening screws of the cam to reverse it. When the cam action is too late, the fastening screw of the cam should be loosened and the cam should be rotated forward to avoid interference between the actions of various mechanisms. After adjusting the "timing" of each cam, the main motor shaft should be continuously rotated using the handle to keep the filling turntable running for one or two weeks. After confirming that there is no interference with the movement of each mechanism, the machine power can be turned on.
(8)Capsule machineThe electrical control system. The machine has three operating modes: jog, auto, and debug.
The difference between automatic mode and debugging mode is that when selecting automatic mode, the four side doors of the working surface must be closed in order to start the main motor. If the debugging mode is selected, the main motor can also be started when opening the four side doors of the workbench. The frequency converter continuously adjusts the main motor, and then starts and stops the frequency converter through the normally open contacts of the main contactor to start and stop the main motor.
The capsule machine has an automatic alarm system for empty capsules and insufficient medication particles. When empty capsules or drug particles are missing, an alarm will begin to prompt the operator to add materials.