How to clean spiral ducts? No matter what product you buy, when choosing a device, you need to find a reliable manufacturer, and choose a good product based on the chosen product. Nowadays, with the development of this technology, different manufacturers need to consider the parameters of the equipment and how it is used when producing products? For example, the spiral duct equipment mentioned now. Is it necessary to regularly clean stainless steel spiral ducts?
With the continuous extension of use time, a large amount of impurities will be generated inside the stainless steel spiral duct. These impurities will be stored in the pipeline for a long time, accelerating the condensation of oil during operation, causing excessive temperature transition and damage to components such as air valves and hydraulic systems, which has a significant impact on normal operation. Therefore, it is necessary to regularly clean this product. So, how should we clean it?
When connecting the product to the fan, add a flexible joint at the inlet and outlet vents, with the same cross-sectional size as the fan inlet and outlet vents. The hose joint can be made of canvas, synthetic leather and other materials. The length of the hose should not be less than 200, and the tightness should be appropriate. The flexible hose can buffer the vibration of the fan. Before connecting the product to the dust removal equipment and heating equipment, the prefabrication and installation should be stopped according to the theoretical drawing after the equipment is completed.
When installing stainless steel spiral ducts, both the inlet and outlet should have openings during prefabrication. If a hole needs to be opened on the air duct at the end of the product, the joint should be tightened. When transporting condensed water or gases with high moisture content, the product level should be set with a slope and connected to the drainage pipe at a very low point. There should be no longitudinal seams at the bottom during installation, and sealing treatment should be stopped at the bottom seams. Install jumper wires at the product connection flange and connect them to the electrostatic grounding grid for steel plate air ducts that transport flammable and explosive gases.
When the horizontal height of the product is greater than 4m, the installation personnel should fasten it properly. The springboard on the scaffold or mobile support should be fixed properly, and the width of the springboard should comply with the specifications. The installation personnel on the scaffold must handle items and bags to prevent objects or drills from falling and injuring people. After the double suspension bracket is installed inside the stainless steel spiral air duct, the cross arm should be straightened and the suspension rod should not be replaced. The double suspension rod should be evenly stressed.
Briefly describe the production method of stainless steel common plate flange air ducts, also known as non flange air ducts. The faster and more convenient the production and processing speed of stainless steel common plate flange air ducts. Its advantage is to save materials and reduce engineering investment; Reducing energy consumption and saving operating costs are highly welcomed by construction companies.
The equipment required for producing this product includes: multifunctional shearing machine, multifunctional edge biting machine, multifunctional reinforcing machine, common plate flange forming machine, common plate flange matching folding machine, and multifunctional corner code and hook code punching machine.
Stainless steel common plate flange production: Standard straight pipes are directly pressed into connected flanges on the assembly line. After cutting non-standard straight pipes, elbows, tees, tees, fittings, etc., TDF flange forming is completed on a single machine equipment. The flange corners are directly stamped and formed by molds, and can be clamped at the four corners during installation.
The connection between products is made of flange cards, which are made of galvanized steel plates. After being formed by a product card forming machine, they are cut into uniform sizes for installation and connection. The product is integrated with the steel plate of the pipeline, without the need for drilling and riveting like angle steel products. Specific flange clamps are used to connect the two sections of the pipeline, and bolts are used to connect the four corners at a 90 degree angle. Easy to operate, increased efficiency, smooth and even appearance, accurate size, strong interchangeability, and stable product quality.
What should we do if the stainless steel welded air duct is damaged during installation? The use of stainless steel welded air ducts plays a very important role in people's daily lives, because stainless steel spiral air ducts can effectively change the gas conversion between indoor and outdoor environments, endangering the gas inhaled by people. Expand reading on 'Which centrifugal fan manufacturer is good in Liaoyuan'
If the product is damaged, it can be repaired with sealant; If the aluminum foil layer on the outer surface of the pipeline is damaged, but the glass fiber insulation layer is not damaged, qualified aluminum foil sheets can be used to repair the aluminum foil surface of the pipeline. If the damaged fiberglass insulation layer has been reached, the damaged area can be cut off, and another complete board can be selected and cut according to the specifications of the cut glass panel. Then, brush repair glue and adhesive on the surrounding sockets, and seal them according to the processing technology standards. When the product is working normally, it needs to be checked regularly to prevent work delays. How to clean spiral ducts? If you have any further questions about this spiral duct, you can directly contact customer service.