Zhengzhou Chengyue Scientific Instrument Co., Ltd
Home>Products>High precision 10 channel injection pump
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13837189935
  • Address
    401, 4th Floor, Building 5, Zhengzhou Yida Technology New City, Jinzhan Street, High tech Zone, Zhengzhou City
Contact Now
High precision 10 channel injection pump
Brief introduction: The high-precision 10 channel infusion pump is a 10 channel infusion/extraction type infusion pump mainly used in biological labor
Product details
Details introduction:

The main functions of the high-precision 10 channel injection pump are:

1. Syringe inner diameter input function: You can select syringes from a list or directly input the syringe inner diameter

2. The microinjection pump has a user-friendly human-machine interface: a large screen LCD display, digital knobs combined with thin film buttons for easy and fast operation.

3. Four working modes: infusion mode, extraction mode, extraction infusion mode, and continuous mode.

4. Power off memory function: (1) EEPROM saves the set parameters, and there is no need to reset them after powering on again. (2) When running in streaming mode, power is cut off, and after power is restored, it can continue to run or stop according to the set parameters.

5. Traffic jam protection function: When the propulsion mechanism of the infusion pump is blocked during operation, the infusion pump will stop the operation of the propulsion mechanism and sound a whistle alarm.

6. The 485 communication bus can be connected to the upper computer and controlled through backend software.

7. External control interface: equipped with input/output control function. Flow calibration function: More accurate flow can be obtained through the calibration program. Syringe protection function: By adjusting the position of the limit block, the syringe can be prevented from being damaged

Technical parameters of high-precision 10 channel injection pump:

Working mode of microinjection pump

pour into

Flow range

0.831ul/min to 21.675ml/min

Number of syringes that can be installed

10

Max's itinerary

140mm

Travel resolution

0.156µm

Linear velocity range

5 µ m/min-130mm/min (flow rate=linear velocity x injector area)

Linear velocity adjustment resolution

5µm/min

Travel control accuracy

Error ≤± 0.5% (when the stroke is ≥ 30% of the maximum stroke)

Rated linear thrust

>180N

Syringe selection

Main manufacturers and models of syringes are available for selection

Definition of Syringe

Can directly input the inner diameter of the syringe

Flow correction

Obtain more accurate liquid volume through calibration program

Run parameter settings

Distribution volume, injection time, etc

Display parameter selection

Liquid volume, flow rate or linear velocity

Power off memory

After powering on again, you can choose whether to continue working in the disconnected state

Status signal output

2-channel OC gate signal output, used to indicate start/stop and direction status

Control signal input

2-channel start/stop control input, 1-channel falling edge trigger signal controls start/stop; 1-channel TTL level signal controls start stop

communication interface

RS485

External dimensions

280×210×140(mm)

weight

4.5kg

Use power supply

AC

200V-260V/35W

Relative humidity of working environment

<80%

Ambient Temperature

0℃- 40℃