HACH Multi Parameter Water Quality Analyzer MS6100Continuous monitoring of residual chlorine, total chlorine, turbidity pH、ORP、 7 parameters of conductivity and temperature.
The turbidity module of the multi parameter water quality analyzer MS6100 adopts 360 ° X90 ° detection technology, which is more accurate.
The HaXi multi parameter water quality analyzer MS6100 has low maintenance and flexible configuration.
The HACH multi parameter water quality analyzer MS6100 adopts the following detection methods for 7 parameters:
Residual chlorine/total chlorine: N, N-diethyl-1,4-phenylenediamine photometric method (DPD method)
Turbidity: 90 ° scattering turbidity method, collecting scattered light 360 ° around the incident beam;
PH/ORP/conductivity: electrochemical method;
Temperature: NTC30K
-Application industry:
The HACH Multi Parameter Water Quality Analyzer MS6100 can be applied to drinking water pipe networks, secondary water supply, and swimming pool water.
-Instrument features:
MS6100 can continuously monitor residual chlorine, total chlorine, turbidity pH、ORP、 7 water quality parameters including conductivity and temperature
The MS6100 turbidity module adopts a new 360 ° x90 ° detection technology, making turbidity testing faster, more accurate, and convenient
MS6100 configuration is flexible and optional, with complete communication functions
MS6100 has a small footprint, is easy to install, and requires lower maintenance. It is specifically designed for unmanned applications
HACH Multi Parameter Water Quality Analyzer MS6100TECHNICAL INDEX | |
---|---|
Measurement parameters | Residual chlorine, total chlorine, turbidity pH、ORP、 Conductivity and temperature |
measuring method |
Residual chlorine/total chlorine: N, N-diethyl-1,4-phenylenediamine photometric method (DPD method) Turbidity: 90 degree scattering turbidity method, collecting scattered light 360 degrees around the incident beam; PH/ORP/conductivity: electrochemical method; Temperature: NTC30K |
measuring range |
Residual chlorine/total chlorine: 0-5 mg/L as CL2; Turbidity: 0-20 NTU; pH:4.00 ~ 10.00; ORP:-1200 mV ~ +1200 mV; Conductivity: 20.0 μ S/cm~2000 μ S/cm; Temperature: 0 ° C~50 ° C |
Detection limit |
Residual chlorine/total chlorine: 0.03 mg/L; Turbidity: 0.0032 NTU; Conductivity: 6.0 μ S/cm |
accuracy |
Residual chlorine/total chlorine: ± 5% or ± 0.03 mg/L as CL2 (whichever is greater); Turbidity: ± 2% or ± 0.01 NTU (whichever is higher); (Based on Formazin primary standard solution at 25 ° C) pH:±0.02; ORP:±20 mV; Conductivity: ± 0.8% F.S; Temperature: ± 0.4 ° C |
repeatability |
Residual chlorine/total chlorine: 5% or 0.01 mg/L as CL2 (whichever is greater); Turbidity: 1% or 0.006 NTU (whichever is higher); (Based on Formazin primary standard solution at 25 ° C) pH:0.01; ORP:10 mV; Conductivity: 0.4% F.S; Temperature: 0.2 ° C |
response time |
Electrochemical electrode (pH electrode/ORP electrode/conductivity electrode) T90 response time<3=''> The T90 response time of the entire system (calculated from the moment the water sample enters the instrument) is less than 10=''> |
Measurement Interval |
The measurement interval for residual chlorine/total chlorine can be configured (continuous mode, 5 minutes, 10 minutes, 15 minutes, 20 minutes, 30 minutes); Continuous measurement of turbidity/pH/ORP/conductivity/temperature |
Calibration |
Residual chlorine/total chlorine calibration: calibrated at the factory, using the default calibration curve; Turbidity calibration: StabCal ® Single point calibration (20 NTU), Formazin two-point calibration, customized calibration from 2 to 6 points; PH calibration: single point calibration, two-point calibration, three-point calibration; Conductivity calibration: single point calibration |
operation temperature | 0 ° C to+45 ° C |
sample temperature | 4 ° C~40 ° C. |
storage temperature |
Instrument: -20 ° C to+55 ° C; Electrode: -15 ° C to+55 ° C |
relative humidity | 5%~95% (no condensation) |
Power requirements | (220 ± 20) VAC/50 Hz (factory default configuration); Or (115 ± 5) VAC/60 Hz (manual switching required); |
Analog Output | 7-channel isolated 4-20 mA output |
Digital Output |
2 RS485 interfaces (one of which supports MODBUS) Protocol, another supports Hach SC protocol). |
Sample flow rate |
The instrument injection flow path is divided into two parts, and the injection flow rate of each flow path can be adjusted separately by the user: -Chlorine module flow regulation range: 120-180 milliliters per minute (recommended: 165 milliliters per minute); -Turbidity (electrochemical) module flow regulation range: 150-450 mL/min (recommended: 250 mL/min) |
authentication |
CE certification; ETL certification. |
Shell protection | IP65 (with door with sealing strip and door latch) |
size | 49.0 cm (width) x 80.0 cm (height) x 36.5 cm (thickness) |
Shipping weight | 45 kilograms (including packaging) |
HACH Multi Parameter Water Quality Analyzer MS6100 Ordering Guide | |
---|---|
8325700 | MS6100.101 (turbidity+single channel chlorine/standard motherboard) |
8325800 | MS6100.102 (turbidity+single channel chlorine/fully equipped motherboard) |
8325900 | MS6100.111 (turbidity+single channel chlorine+electrochemical module/standard motherboard) |
8332500 | MS6100.112 (turbidity+single channel chlorine+electrochemical module/fully equipped motherboard) |
8329400 | MS6100.201 (turbidity+dual channel chlorine/standard motherboard) |
8329800 | MS6100.202 (turbidity+dual channel chlorine/fully equipped motherboard) |
8330000 | MS6100.211 (turbidity+dual channel chlorine+electrochemical module/standard motherboard) |
8330600 | MS6100.212 (turbidity+dual channel chlorine+electrochemical module/fully equipped motherboard) |
8331800 | MS6100 pH electrode (including packaging) |
8326800 | MS6100 Conductivity Electrode (including packaging) |
8331600 | MS6100 ORP electrode (including packaging) |