Running Industrial (Shanghai) Co., Ltd
Home>Products>HACH Multi Parameter Water Quality Analyzer MS6100
HACH Multi Parameter Water Quality Analyzer MS6100
The HACH Multi Parameter Water Quality Analyzer MS6100 can be applied to industries such as drinking water pipe networks, secondary water supply, and
Product details

HACH Multi Parameter Water Quality Analyzer MS6100Continuous monitoring of residual chlorine, total chlorine, turbidity pH、ORP、 7 parameters of conductivity and temperature.

The turbidity module of the multi parameter water quality analyzer MS6100 adopts 360 ° X90 ° detection technology, which is more accurate.

The HaXi multi parameter water quality analyzer MS6100 has low maintenance and flexible configuration.

The HACH multi parameter water quality analyzer MS6100 adopts the following detection methods for 7 parameters:

Residual chlorine/total chlorine: N, N-diethyl-1,4-phenylenediamine photometric method (DPD method)

Turbidity: 90 ° scattering turbidity method, collecting scattered light 360 ° around the incident beam;

PH/ORP/conductivity: electrochemical method;

Temperature: NTC30K


-Application industry:

The HACH Multi Parameter Water Quality Analyzer MS6100 can be applied to drinking water pipe networks, secondary water supply, and swimming pool water.


-Instrument features:

MS6100 can continuously monitor residual chlorine, total chlorine, turbidity pH、ORP、 7 water quality parameters including conductivity and temperature

The MS6100 turbidity module adopts a new 360 ° x90 ° detection technology, making turbidity testing faster, more accurate, and convenient

MS6100 configuration is flexible and optional, with complete communication functions

MS6100 has a small footprint, is easy to install, and requires lower maintenance. It is specifically designed for unmanned applications

HACH Multi Parameter Water Quality Analyzer MS6100TECHNICAL INDEX
Measurement parameters Residual chlorine, total chlorine, turbidity pH、ORP、 Conductivity and temperature
measuring method Residual chlorine/total chlorine: N, N-diethyl-1,4-phenylenediamine photometric method (DPD method)
Turbidity: 90 degree scattering turbidity method, collecting scattered light 360 degrees around the incident beam;
PH/ORP/conductivity: electrochemical method;
Temperature: NTC30K
measuring range Residual chlorine/total chlorine: 0-5 mg/L as CL2;
Turbidity: 0-20 NTU;
pH:4.00 ~ 10.00;
ORP:-1200 mV ~ +1200 mV;
Conductivity: 20.0 μ S/cm~2000 μ S/cm;
Temperature: 0 ° C~50 ° C
Detection limit Residual chlorine/total chlorine: 0.03 mg/L;
Turbidity: 0.0032 NTU;
Conductivity: 6.0 μ S/cm
accuracy Residual chlorine/total chlorine: ± 5% or ± 0.03 mg/L as CL2 (whichever is greater);
Turbidity: ± 2% or ± 0.01 NTU (whichever is higher); (Based on Formazin primary standard solution at 25 ° C)
pH:±0.02;
ORP:±20 mV;
Conductivity: ± 0.8% F.S;
Temperature: ± 0.4 ° C
repeatability Residual chlorine/total chlorine: 5% or 0.01 mg/L as CL2 (whichever is greater);
Turbidity: 1% or 0.006 NTU (whichever is higher); (Based on Formazin primary standard solution at 25 ° C)
pH:0.01;
ORP:10 mV;
Conductivity: 0.4% F.S;
Temperature: 0.2 ° C
response time Electrochemical electrode (pH electrode/ORP electrode/conductivity electrode) T90 response time<3=''>
The T90 response time of the entire system (calculated from the moment the water sample enters the instrument) is less than 10=''>
Measurement Interval The measurement interval for residual chlorine/total chlorine can be configured (continuous mode, 5 minutes, 10 minutes, 15 minutes, 20 minutes, 30 minutes);
Continuous measurement of turbidity/pH/ORP/conductivity/temperature
Calibration Residual chlorine/total chlorine calibration: calibrated at the factory, using the default calibration curve;
Turbidity calibration: StabCal ® Single point calibration (20 NTU), Formazin two-point calibration, customized calibration from 2 to 6 points;
PH calibration: single point calibration, two-point calibration, three-point calibration;
Conductivity calibration: single point calibration
operation temperature 0 ° C to+45 ° C
sample temperature 4 ° C~40 ° C.
storage temperature Instrument: -20 ° C to+55 ° C;
Electrode: -15 ° C to+55 ° C
relative humidity 5%~95% (no condensation)
Power requirements (220 ± 20) VAC/50 Hz (factory default configuration); Or (115 ± 5) VAC/60 Hz (manual switching required);
Analog Output 7-channel isolated 4-20 mA output
Digital Output 2 RS485 interfaces (one of which supports MODBUS)
Protocol, another supports Hach SC protocol).
Sample flow rate The instrument injection flow path is divided into two parts, and the injection flow rate of each flow path can be adjusted separately by the user:
-Chlorine module flow regulation range: 120-180 milliliters per minute (recommended: 165 milliliters per minute);
-Turbidity (electrochemical) module flow regulation range: 150-450 mL/min (recommended: 250 mL/min)
authentication CE certification;
ETL certification.
Shell protection IP65 (with door with sealing strip and door latch)
size 49.0 cm (width) x 80.0 cm (height) x 36.5 cm (thickness)
Shipping weight 45 kilograms (including packaging)
HACH Multi Parameter Water Quality Analyzer MS6100 Ordering Guide
8325700 MS6100.101 (turbidity+single channel chlorine/standard motherboard)
8325800 MS6100.102 (turbidity+single channel chlorine/fully equipped motherboard)
8325900 MS6100.111 (turbidity+single channel chlorine+electrochemical module/standard motherboard)
8332500 MS6100.112 (turbidity+single channel chlorine+electrochemical module/fully equipped motherboard)
8329400 MS6100.201 (turbidity+dual channel chlorine/standard motherboard)
8329800 MS6100.202 (turbidity+dual channel chlorine/fully equipped motherboard)
8330000 MS6100.211 (turbidity+dual channel chlorine+electrochemical module/standard motherboard)
8330600 MS6100.212 (turbidity+dual channel chlorine+electrochemical module/fully equipped motherboard)
8331800 MS6100 pH electrode (including packaging)
8326800 MS6100 Conductivity Electrode (including packaging)
8331600 MS6100 ORP electrode (including packaging)
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!