Running Industrial (Shanghai) Co., Ltd
Home>Products>HACH Hash Laboratory/Portable Water Quality Analyzer Product List
HACH Hash Laboratory/Portable Water Quality Analyzer Product List
Hash Laboratory/Portable Water Quality Analyzer Product List, HACH Laboratory/Portable Water Quality Analyzer Accessory List
Product details
American Hash Product Name/Model HACH Order Number notes
Hash UV Visible Spectrophotometer DR6000 LPV441.99.00002 Wavelength range: 190-1100nm, wavelength accuracy: ± 1nm (200-900nm), preset programs: over 250, user programs: 200, data storage: 5000 measurement values, display: Chinese color touch screen, interface: USB, Ethernet, power supply: 220VAC
Rotating adapter (capable of accommodating 7 rectangular sample tanks of 1cm) LZV902.99.00002
Rotating adapter (capable of accommodating 5 1-inch rectangular sample tanks) LZV902.99.00012
1cm rectangular colorimetric dish, quartz 2624410
5cm rectangular colorimetric dish, quartz 2624450
5cm rectangular colorimetric dish, glass 2629250
10cm rectangular colorimetric dish adapter LZV887
10cm rectangular colorimetric dish, 1 piece 2629201
filter plate LZV915
LAMP A23792
Tungsten halogen lamp A23778
1cm rectangular colorimetric dish, glass 2095100 1 pair
1cm rectangular colorimetric dish, quartz 4822800 1 pair
DR6000 PC version operating software LZV938
USB interface (required with LZV938) LZV632
printer LQV161.99.10000
HACH Visible Spectrophotometer DR3900 LPV440.99.00002 Wavelength range: 320-1100nm, wavelength accuracy: ± 1.5nm (340-900nm), preset programs: over 240, user programs: 100, data storage: 2000 measurement values, display: Chinese color touch screen, interface: USB, Ethernet, power supply: 220VAC
tungsten lamp LZV565

Colorimetric pool

2495402

1-inch rectangular colorimetric dish, paired, glass (10 milliliters)
Hash portable spectrophotometer DR1900 DR1900-05K Includes DR1900 host and USB+charging LZV81.39.90002, wavelength range: 340-800nm, wavelength accuracy: ± 2nm, preset programs: over 260, user programs: 50, data storage: 500 measurement values, display: Chinese touch screen, interface: mini
USB, Power supply: 4 AA batteries, protection level: FIP67 HACH portable spectrophotometer DR1900 DR1900-05C
Includes DR1900 host, wavelength range: 340-800nm, wavelength accuracy: ± 2nm, preset programs: over 260, user programs: 50, data storage: 500 measurement values, display: Chinese touch screen, interface: mini USB, Power supply: 4 AA batteries, protection level: FIP67 Hash Portable Water Quality Analysis Laboratory (Universal) DREL1900
2922401-CN Including a DR1900 portable spectrophotometer, reagents and testing components required to measure 24 different parameters (these reagents and testing components can perform approximately 100 tests) HACH Portable Water Quality Analysis Laboratory (Complete Type) DREL1900
2922601-CN Including a DR1900 portable spectrophotometer, digital titrator, 2100Q portable turbidity meter, pH/conductivity meter, pH electrode and conductivity electrode, reagents and testing components required to measure 24 different parameters (these reagents and testing components can perform approximately 100 tests) Hash portable multi parameter colorimeter DR900
9385100-CN Wavelength: 420, 520, 560, and 610nm, wavelength accuracy: ± 1nm, preset program: 90, user program: 10, data storage: 500 measurement values, display: Chinese backlit LCD, interface: Mini USB, Power supply: 4 AA batteries, protection level: IP67
HACH portable residual chlorine total chlorine detector DR300 LPV445.80.00110 Absorption range 0-2.5 Abs sample cell protection level IP67, waterproof for 30 minutes at a water depth of 1 meter
Free residual chlorine reagent 2105569-CN Range: 0.02 to 2.00 mg/L
OR 0.1to 8.0 mg/L; 100/pkg Total residual chlorine reagent 2105669-CN
Range: 0.02 to 2.00 mg/L OR 0.1to 8.0 mg/L; 100/pkg Hash portable residual chlorine total chlorine detector DR300
LPV445.97.62110 Absorption range 0-2.5 Abs sample cell protection level IP67, waterproof for 30 minutes at a water depth of 1 meter Free residual chlorine reagent
1407099-CN Range: 0.05 to 4.00
mg/L, Range: 0.1 to 10.0 mg/L Total residual chlorine reagent 1406499-CN
Range: 0.05 to 4.00 mg/L, Range: 0.1 to 10.0 mg/L
HACH portable chlorine dioxide detector DR300 LPV445.80.51110 Chlorine dioxide reagent
2770900-CN Range: 0.04 to 5.00 mg/L; 100 tests
Hash portable ozone colorimeter DR300 LPV445.97.04110
Ozone reagent 2516025-CN 0.01~0.25 mg/l
O3,PK/25 9185000 Ozone reagent
2517025-CN
0.01~0.75 mg/l 9185700 O3,PK/25
HACH portable ammonia nitrogen detector DR300
LPV445.97.40110
Ammonia nitrogen reagent 2668000-CN Range: 0.01 to 0.80 mg/L
NH3–N; 100 tests Hash Laboratory COD Tester DR1010 Including: DR1010 instrument host, power adapter, data transmission cable, instrument operation manual, instrument method manual, certificate of conformity
DR1010: Wavelength range: 420nm and 610nm, wavelength accuracy: ± 1nm, display: LCD, power supply: 220VAC or 4 AA alkaline batteries. HACH Laboratory COD Tester DR1010 Instrument (Set 1) Including: one set of DR1010 instrument and one set of DRB200 digester.
DR1010: Wavelength range: 420nm and 610nm, wavelength accuracy: ± 1nm, display: LCD, power supply: 220VAC or 4 AA alkaline batteries. DRB200: equipped with 15 16mm digestion wells, power supply: 220VAC. High temperature digester HT200S
LTV077 Includes 20mm to 13mm adapter 15 hole digestion device DRB200
LTV082.80.40001 Equipped with 15 16mm digestion holes, power supply: 220VAC 11 hole digestion device DRB200
LTV082.80.30001 Equipped with 9 16mm and 2 20mm digestion holes, power supply: 220VAC 25 well digestion device DRB200
LTV082.80.42001 Equipped with 21 16mm and 4 20mm digestion holes, power supply: 220VAC 30 well digestion device DRB200
LTV082.80.44001 Equipped with 30 16mm digestion holes, power supply: 220VAC Total nitrogen reagent (2-150mg/L)
2714100-CN Range: 2 to 150 mg/L N;25-50tests; DRB200 15 x 16 mm
Total nitrogen reagent (0.5-25.0mg/L) 2672245-CN Range: 0.5 to 25.0 mg/L
N;25-50tests; DRB200 15 x 16 mm Ammonia nitrogen reagent (0.02-2.50mg/L) 2604545-CN
Range: 0.02-2.50 mg/L NH3–N; Salicylic acid method; 25-50 tests Ammonia nitrogen reagent (0.4-50.0 mg/L)
2606945-CN Range: 0.4 to 50.0 mg/L NH3–N; 50 tests
Total phosphorus reagent (0.06-3.50mg/L) 2742645-CN Range: 0.06 to 3.50 mg/L
PO43–; 50 tests; DRB200 15 x 16 mm Total phosphorus reagent (1.0-1000mg/L) 2767245-CN
Range: 1.0 to 100.0 mg/L PO43–; 25-50tests; DRB200 15 x 16 mm COD reagent (0.7-40mg/L)
2415815-CN PK/150 COD reagent (3-150mg/L)
2125815-CN PK/150 COD reagent (20-1500mg/L)
2125915-CN PK/150 COD reagent (200-15000mg/L)
2415915-CN PK/150 COD rapid digestion reagent (15-150mg/L)
2038215-CN PK/150 COD rapid digestion reagent (100-1000mg/L)
2038315-CN PK/150 High salt COD test - HR
TNT816-CN HR (70 - 700 mg/L COD), 25 Tests For saline COD samples
with Chloride concentrations up to 20,000 mg/L Cl-! High salt COD test LR TNT815-CN
LR (7 - 70 mg/L 8509500 COD), 25 Tests
Hash PH Meter HQ1110 Host LEV015.80.1110A Display: LED, single channel
Liquid filled standard composite pH electrode PHC30101 PH:0-14PH, Temperature: -10~+110 ℃, with 1m cable,
Portable pH meter HQ1110 host LEV015.80.1110A Display: LED, single channel
Gel solid composite PH electrode PHC10105 PH:2-14PH, Temperature: -0~+80 ℃, with 5m cable
Hash pure water pH meter HQ1110 host LEV015.80.1110A Display: LED, single channel
Pure water pH electrode PHC73501 Can be used to measure seawater, dirty samples, or pure water
HACH desktop conductivity meter HQ411D Desktop pH/MV analyzer, PH:0-14PH, Temperature: -10~+110 ℃, with 1m cable, Hash desktop pH meter host
HQ411D Desktop PH/MV analyzer Liquid filled standard composite pH electrode
PHC30101 PH:0-14PH, Temperature: -10~+110 ℃, with 1m cable, HACH Portable ORP Instrument HQ1110 Host
LEV015.80.1110A Display: LED, single channel Liquid filled standard composite ORP electrode
MTC30101 Range: ± 1200mv, with 1m cable Hash Portable ORP Instrument HQ1110 Host
LEV015.80.1110A Display: LED, single channel Liquid filled standard composite ORP electrode
MTC30103 Range: ± 1200mv, with 3m cable Portable ORP Instrument HQ1110 Host
LEV015.80.1110A Display: LED, single channel Gel solid composite ORP electrode
MTC10105 8509600 Range: ± 1200mv, with 5m cable
Hash portable conductivity meter HQ1140 host LEV015.80.1140A Display: LED, single channel
Standard conductivity electrode CDC40101 Conductivity: 0.01 μ s/cm-200ms/cm, temperature: -10~+110 ℃, resistivity: 2.5 Ω· cm-49M Ω· cm, TDS: 0-50000mg/L, salinity: 0-42g/kg, with 1m cable
HACH portable conductivity meter HQ1140 host LEV015.80.1140A Display: LED, single channel
Standard conductivity electrode CDC40103 Conductivity: 0.01 μ s/cm-200ms/cm, temperature: -10~+110 ℃, resistivity: 2.5 Ω· cm-49M Ω· cm, TDS: 0-50000mg/L, salinity: 0-42g/kg, with 3m cable
Portable Conductivity Meter HQ1140 Host LEV015.80.1140A Display: LED, single channel
Durable conductivity electrode CDC40105 Conductivity: 0.01 μ s/cm-200ms/cm, temperature: -10~+110 ℃, resistivity: 2.5 Ω· cm-49M Ω· cm, TDS: 0-50000mg/L, salinity: 0-42g/kg, with 5m cable
Hash desktop conductivity meter HQ430D 1-meter cable HACH portable dissolved oxygen analyzer HQ1130 host
LEV015.80.1130A Display: LED, single channel Standard dissolved oxygen electrode
LDO10103 Dissolved oxygen: 0-20mg/L, with 3m cable Hash portable dissolved oxygen analyzer HQ1130 host
LEV015.80.1130A Display: LED, single channel Durable dissolved oxygen electrode
LDO10105 Dissolved oxygen: 0-20mg/L, with 5m cable HACH desktop dissolved oxygen analyzer host
HQ430D Desktop multi parameter single channel measuring instrument Standard dissolved oxygen electrode
LDO10101 Dissolved oxygen: 0-20mg/L, with 1m cable Hash desktop dissolved oxygen analyzer host
HQ440D Desktop multi parameter dual channel measuring instrument Standard dissolved oxygen electrode
LDO10101 Dissolved oxygen: 0-20mg/L, with 1m cable Hash portable multi parameter analyzer HQ2200 host
LEV015.80.2200A Display: LED, dual channel Gel PH electrode
PHC10103 PH:2-14PH, Temperature: -0~+80 ℃, with 3m cable, Liquid filled standard composite ORP electrode
MTC30101 Range: ± 1200mv, with 1m cable Liquid filled standard composite pH electrode
PHC30101 PH:0-14PH, Temperature: -10~+110 ℃, with 1m cable, Gel type compound PH electrode
PHC10101 PH:2-14PH, Temperature: -0~+80 ℃, with 1m cable, Standard dissolved oxygen electrode
LDO10101 Dissolved oxygen: 0-20mg/L, with 1m cable Standard conductivity electrode
CDC40101 Conductivity: 0.01 μ s/cm-200ms/cm, temperature: -10~+110 ℃, resistivity: 2.5 Ω· cm-49M Ω· cm, TDS: 0-50000mg/L, salinity: 0-42g/kg, with 1m cable HACH portable analyzer HQ2200 host
LEV015.80.2200A Display: LED, dual channel Standard dissolved oxygen electrode
LDO10103 Dissolved oxygen: 0-20mg/L, with 3m cable Liquid filled standard composite ORP electrode
MTC30103 Range: ± 1200mv, with 3m cable Liquid filled standard composite pH electrode
PHC30103 PH:0-14PH, Temperature: -10~+110 ℃, with 3m cable, Standard conductivity electrode
CDC40103 Conductivity: 0.01 μ s/cm-200ms/cm, temperature: -10~+110 ℃, resistivity: 2.5 Ω· cm-49M Ω· cm, TDS: 0-50000mg/L, salinity: 0-42g/kg, with 3m cable Hash portable water quality analyzer HQ2200 host
LEV015.80.2200A Display: LED, dual channel Gel solid composite PH electrode
PHC10105 Range: 2-14PH, 0~+80 ℃, with 5m cable, Durable dissolved oxygen electrode
LDO10105
Dissolved oxygen: 0-20mg/L, with 5m cable

Durable conductivity electrode
CDC40105
Conductivity: 0.01 μ s/cm-200ms/cm, temperature: -10~+110 ℃, resistivity: 2.5 Ω· cm-49M Ω· cm, TDS: 0-50000mg/L, salinity: 0-42g/kg, with 5m cable Gel solid composite ORP electrode MTC10105
Range: ± 1200mv, with 5m cable Portable multi parameter water quality analyzer HQ4200 host LEV015.80.4200A
Display: LED, dual channel Ammonia electrode analysis kit ISENH3181AP-CN
ISENH3181 ammonia electrode, 1-meter cable, 500mL ammonia nitrogen standard solution (1,10100mg/L), one bottle each; Ammonia ion strength regulator powder pillow 100/PK; ammonia electrode storage solution, 500mL, ammonia membrane module 3/PK HQ40d
HQ40D Display: LCD, power supply: 220VAC or 4 AA batteries Ammonium ion analysis package
ISENH4181AP-CN ISENH4181 ammonium electrode, 1-meter cable, 500mL ammonia nitrogen standard solution (10100mg/L), one bottle each; Ammonium ion strength regulator powder pillow 100/PK
Sodium ion analysis package ISENA381AP-CN ISENA381 sodium ion electrode, 1-meter cable, sodium ion electrode filling solution 0.02M
NH4CL,50mL, Sodium ion standard solution 100mg/L, 1L, sodium ion strength regulator powder pillow 100/PK; filling liquid bottle separation cap, sodium ion standard solution 1000mg/L, 500mL, range: 0.023mg/L (1 × 10-6M)~23000 mg/L(1M)Na+
PH working range: 4-14 Chloride ion analysis package ISECL181AP-CN
ISECL181 chloride ion electrode, 1-meter cable, chloride ion standard solution, 100mg/L, 1L; Chloride ion strength regulator powder pillow 100/PK; chloride ion standard solution 1000mg/L, 500mL Fluoride ion analysis package
ISEF121AP-CN ISEF121 fluoride ion electrode, 1-meter cable, fluoride ion strength regulator powder pillow 100/PK; Fill the liquid bottle with a separation cap, fluoride ion standard solution 0.5, 1.0, 2.0 mg/L, 500 mL
Nitrate ion analysis kit ISENO3181AP-CN ISENO3181 nitrate ion electrode, 1-meter cable, 500mL nitrate nitrogen standard solution (1,10100mg/L), one bottle each; Nitrate ion strength regulator powder pillow
100/PK; HACH Portable pH/ORP Electrochemical Tester Host HQ1110 LEV015.80.1110A
HQ1110 Handheld portable pH/ORP electrochemical tester Single channel, USB socket charger 5.0V-2.0A, 18650 lithium battery 3.7V, 12.6WH, wristband, HQ basic user manual, quick start manual, QC factory inspection report
Hash portable dissolved oxygen analyzer HQ1130 LEV015.80.1130A HQ1130 Handheld Portable DO Electrochemical Tester
Single channel, USB socket charger 5.0V-2.0A, 18650 lithium battery 3.7V, 12.6WH, wristband, HQ basic user manual, QC factory inspection report Portable conductivity meter HQ1140 LEV015.80.1140A
HQ1140 Handheld Portable Conductivity Electrochemical Tester Single channel, USB socket charger 5.0V-2.0A, 18650 lithium battery 3.7V, 12.6WH, wristband, HQ basic user manual, QC factory inspection report Portable pH/EC/TDS/DO analyzer HQ2100
LEV015.80.2100A HQ2100 Handheld portable pH/ORP/conductivity/TDS/DO electrochemical tester
Single channel, USB socket charger 5.0V-2.0A, 18650 lithium battery 3.7V, 12.6WH, wristband, HQ basic user manual, QC factory inspection report Portable pH/EC/TDS/DO analyzer HQ2200 (dual channel) LEV015.80.2200A
HQ2200 Handheld portable pH/ORP/conductivity/TDS/DO electrochemical tester Dual channel, USB socket charger 5.0V-2.0A, 18650 lithium battery 3.7V, 12.6WH, wristband, HQ basic user manual, QC factory inspection report
Hash handheld portable multi parameter electrochemical tester HQ4100 (single channel) LEV015.80.4100A HQ4100
Portable multi parameter analyzer (including ion electrode) single channel, USB socket charger 5.0V-2.0A, 18650 lithium battery 3.7V, 12.6WH, wristband, HQ basic user manual, QC factory inspection report HACH Handheld Portable Multi parameter Electrochemical Tester HQ4200 (Dual Channel) LEV015.80.4200A
HQ4200 Portable multi parameter analyzer (including ion electrode) dual channel, USB socket charger 5.0V-2.0A, 18650 lithium battery 3.7V, 12.6WH, wristband, HQ basic user manual, QC factory inspection report HACH Handheld Portable Multi Parameter Electrochemical Tester HQ4300 (Three Channels)
LEV015.80.4300A HQ4300 Portable multi parameter analyzer (including ion electrode) with three channels, USB socket charger 5.0V-2.0A, 18650 lithium battery 3.7V, 12.6WH, wristband, HQ basic user manual, QC factory inspection report
HQ series accessory box LEZ015.80.A001A ACCESSORY BOX,
CHINA, HQ SERIES Hash portable pH detector kit (regular water quality) LEV015.80.11101
HQ1110 single channel host, PHC20101 is a 1m cable gel PH electrode, field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) HACH Portable PH Detector Kit (Conventional Water Quality) LEV015.80.11102
HQ1110 single channel host, PHC10101 is a 1m cable gel electrode, and field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) Hash portable pH detector kit (sewage) LEV015.80.11103
HQ1110 single channel host, PHC10105 is a 5m cable gel solid PH electrode, field test kit (solid sample box, bracket, wrist strap, rubber protective case, paper towel) HACH portable ORP detector kit LEV015.80.11104
HQ1110 single channel host, MTC10105 is a 5m cable gel solid ORP electrode, field test kit (solid sample box, bracket, wrist strap, rubber protective case, paper towel) Hash portable dissolved oxygen detector kit (standard type) LEV015.80.11301
HQ1130 single channel host, LDO10101 is a 1-meter cable fluorescent method LDO electrode, on-site testing kit (standard sample box, bracket, wristband, rubber protective shell, tissue) HACH portable dissolved oxygen detector kit (rugged type) LEV015.80.11302
HQ1130 single channel host, LDO10105 is a 5-meter cable fluorescent method sturdy LDO electrode, on-site testing kit (sturdy sample box, bracket, wristband, rubber protective case, tissue) Hash portable conductivity analyzer kit (standard type) LEV015.80.11401
HQ1140 single channel host, CDC401-1-meter cable, laboratory 4-pole graphite conductive electrode, on-site testing kit (standard sample box, bracket, wristband, rubber protective case, tissue) HACH portable conductivity analyzer kit (rugged type) LEV015.80.11402
HQ1140 single channel host, CDC401-5-meter cable, sturdy laboratory 4-pole graphite conductive electrode, on-site testing kit (sturdy sample box, bracket, wristband, rubber protective case, tissue) Hash portable PH detector HQ2100 regular set LEV015.80.21001
HQ2100 single channel host, Changzhou application test, PHC20101 is a 1m cable gel PH electrode, field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) HACH portable pH detector HQ2100 sewage kit LEV015.80.21002
HQ2100 single channel host, suitable for sewage detection, PHC10101 is a 1m cable gel electrode, field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) Hash portable pH detector HQ2100 sturdy set LEV015.80.21003
HQ2100 single channel host, suitable for sewage detection, PHC10105 is a 5m cable gel solid PH electrode, field test kit (solid sample box, bracket, wrist strap, rubber protective shell, paper towel) HACH portable dissolved oxygen detector HQ2100 basic set LEV015.80.21004
HQ2100 single channel host, LDO10101 is a 1-meter cable fluorescent method LDO electrode, on-site testing kit (standard sample box, bracket, wristband, rubber protective shell, tissue) Hash portable dissolved oxygen detector HQ2100 sturdy set LEV015.80.21005
HQ2100 single channel host, LDO10105 is a 5-meter cable fluorescent method sturdy LDO electrode, on-site testing kit (sturdy sample box, bracket, wristband, rubber protective shell, tissue) HACH portable conductivity detector HQ2100 basic set LEV015.80.21006
HQ2100 single channel host, CDC401-1-meter cable, laboratory 4-pole graphite conductive electrode, on-site testing kit (standard sample box, bracket, wristband, rubber protective case, tissue) Hash portable conductivity detector HQ2100 sturdy set LEV015.80.21007
HQ2100 single channel host, CDC401-5-meter cable, sturdy laboratory 4-pole graphite conductive electrode, on-site testing kit (sturdy sample box, bracket, wristband, rubber protective case, tissue) HACH portable PH/conductivity detector HQ2200/PHC10101/DCD40101 Field LEV015.80.22001
HQ2200 dual channel host, CDC 401-1m cable, a 4-pole graphite conductive electrode in the laboratory, a PHC101-1m cable gel electrode, and a field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) Hash portable PH/conductivity detector HQ2200/PHC10105/CDC40105 Field LEV015.80.22002
HQ2200 dual channel host, CDC 401-5m cable, a solid laboratory 4-pole graphite conductive electrode, a PHC101-5m cable, a solid gel electrode, and a field test kit (solid sample box, bracket, wrist strap, rubber protective shell, paper towel) HACH portable PH/conductivity detector HQ2200/PHC20101/DCD40101 Field LEV015.80.22003
HQ2200 dual channel host, CDC 401-1m cable, one 4-pole graphite conductive electrode in the laboratory, one gel electrode in PHC201-1m cable, field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) Hash portable PH/dissolved oxygen detector HQ2200/PHC20101/LDO10101 Field LEV015.80.22004
HQ2200 dual channel host, one LDO101-1m cable dissolved oxygen electrode, one PHC201-1m cable gel electrode, field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) HACH portable pH/dissolved oxygen detector HQ2200/PHC10101/LDO10101 Field LEV015.80.22005
HQ2200 dual channel host, suitable for sewage detection, one LDO101-1m cable dissolved oxygen electrode, one PHC101-1m cable gel electrode, field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) Hash portable PH/dissolved oxygen detector HQ2200/PHC10105/LDO10105 Field LEV015.80.22006
HQ2200 dual channel host, suitable for sewage detection, one LDO101-5 meter cable solid dissolved oxygen electrode, one PHC101-5 meter cable solid gel electrode, field test kit (solid sample box, bracket, wrist strap, rubber protective shell, paper towel) HACH portable dissolved oxygen detector HQ2200/LDO10105 Field LEV015.80.22008
HQ2200 dual channel host, LDO10105 is a 5-meter cable fluorescent method sturdy LDO electrode, on-site testing kit (sturdy sample box, bracket, wristband, rubber protective case, tissue) Hash Portable PH Meter HQ2200/PHC10105 Field
LEV015.80.22009 HQ2200 dual channel host, suitable for sewage detection, PHC10105 is a 5m cable gel solid PH electrode, field test kit (solid sample box, bracket, wrist strap, rubber protective shell, paper towel)
HACH portable pH meter HQ4100/PHC20101 Field LEV015.80.41001
HQ4100 portable multi parameter analyzer single channel host, PHC20101 is a 1m cable gel PH electrode, field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) Hash portable pH meter (sewage) HQ4100/PHC10101 Field
LEV015.80.41002 Single channel host of HQ4100 portable multi parameter analyzer, PHC10101 is a 1m cable gel electrode, field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) HACH Portable PH Meter HQ4100/PHC10105 Field
LEV015.80.41003 Single channel host of HQ4100 portable multi parameter analyzer, PHC10105 is a 5m cable gel solid PH electrode, field test kit (solid sample box, bracket, wrist strap, rubber protective case, paper towel) Hash portable conductivity meter HQ4100/CDC40101 Field
LEV015.80.41004 HQ4100 portable multi parameter analyzer single channel host, CDC401-1-meter cable, laboratory 4-pole graphite conductive electrode, on-site testing kit (standard sample box, bracket, wristband, rubber protective case, tissue) HACH portable conductivity meter HQ4100/CDC40105 Field
LEV015.80.41005 HQ4100 portable multi parameter analyzer single channel host, CDC401-5-meter cable, sturdy laboratory 4-pole graphite conductive electrode, on-site testing kit (sturdy sample box, bracket, wristband, rubber protective case, tissue) Hash portable PH/conductivity detector HQ4200/PHC20101/DCD40101 Field
LEV015.80.42001 HQ4200 portable multi parameter analyzer dual channel host, CDC 401-1 meter cable, a 4-pole graphite conductive electrode in the laboratory, a PHC201-1 meter cable gel electrode, and a field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) HACH portable PH/conductivity detector HQ4200/PHC10101/DCD40101 Field
LEV015.80.42002 HQ4200 portable multi parameter analyzer dual channel host, CDC 401-1 meter cable, a 4-pole graphite conductive electrode in the laboratory, a PHC101-1 meter cable gel electrode, and a field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) Hash portable PH/conductivity detector HQ4200/PHC10105/CDC40105 Field
LEV015.80.42003 Portable multi parameter analyzer dual channel host, CDC 401-5m cable, a solid laboratory 4-pole graphite conductive electrode, a PHC101-5m cable, a solid gel electrode, and a field test kit (solid sample box, bracket, wrist strap, rubber protective shell, paper towel) HACH portable pH/dissolved oxygen detector HQ4200/PHC10101/LDO10101 Field
LEV015.80.42005 Portable multi parameter analyzer dual channel host, suitable for sewage detection, one LDO101-1m cable dissolved oxygen electrode, one PHC101-1m cable gel electrode, field test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel) Hash portable PH/dissolved oxygen detector HQ4200/PHC10105/LDO10105 Field
LEV015.80.42006 HQ4200 dual channel host, suitable for sewage detection, one LDO101-5 meter cable solid dissolved oxygen electrode, one PHC101-5 meter cable solid gel electrode, field test kit (solid sample box, bracket, wrist strap, rubber protective shell, paper towel) HACH portable multi parameter detector HQ4300/PHC201/CDC/LDO/01 Field
LEV015.80.43001 Three channel host of HQ4300 portable multi parameter analyzer, CDC 401-1 meter cable, one 4-pole graphite conductive electrode in the laboratory, one gel electrode of PHC201-1 meter cable, one LDO 101-1 meter dissolved oxygen electrode, and on-site test kit (standard sample box, bracket, wrist strap, rubber protective shell, paper towel)
Hash portable multi parameter detector HQ4300/PHC101/CDC/LDO/05 Field LEV015.80.43002 HQ4300 three channel host, suitable for sewage detection, one LDO101-5m cable solid dissolved oxygen electrode, one PHC101-5m cable solid gel electrode, one CDC 401-5m solid conductivity electrode, and on-site test kit (solid sample box, bracket, wrist strap, rubber protective case, paper towel)
HQ Standard Suitcase LEZ015.99.A001A HQ sturdy suitcase
LEZ015.99.A002A HQ bracket and wristband LEZ015.99.A003A
HQ protective shell LEZ015.99.A004A HACH desktop turbidity meter TU5200
LPV442.99.01012 TU5200 Laboratory Laser Turbidity Meter, EPA Version Hash desktop turbidity meter TU5200
LPV442.99.01022 KTO: TU5200 Lab
Turb, ISO HACH desktop turbidity meter TL2350
LPV444.80.00310 Turbidity: 0-10000 NTU, Display: 7-inch color touch screen, Power supply: 220VAC
Hash desktop turbidity meter TL2360 LPV444.80.00320
Turbidity: 0-10000 NTU, Display: 7-inch color touch screen, Power supply: 220VAC Thermal printer
LQV161.99.10000 LVV161.531000 discontinued
HACH desktop turbidity meter TL2310 LPV444.80.00120
Range: 0-1000NTU, Display: 7-inch color touch screen, Power supply: 220VAC, ISO version Hash desktop turbidity meter TL2300
LPV444.80.00210 Range: 0-4000NTU, Display: 7-inch color touch screen, Power supply: 220VAC
HACH portable turbidity meter 2100Q 2100Q01-CN
Range: 0-1000NTU, Display: LCD, Power Supply: 4 AA batteries Hash portable turbidity, suspended solids, and sludge interface monitoring instrument TSS Portable LXV322.99.00002
Turbidity: 0.001-4000NTU, SS: 0.001-400g/L, with 10m cable, display: LCD HACH portable turbidity, suspended solids, and sludge interface monitoring instrument probe
LXV321.99.00002 Hash Professional Liquid Colorimeter LICO690
LMV187.99.40001 Color code: With over 25 built-in color codes, wavelength range: 320-1100nm, automatic calibration, wavelength accuracy: ± 1.5nm (wavelength range: 340-900nm), data storage: 1000 absorbance values, 100 chromaticity reference values, 20 wavelength scans, 20 time scans, 3000 chromaticity measurement values, display: color touch screen, interface: USB, Ethernet, power supply: 220VAC
Start Tool Kit LZM354
Containing chromaticity series standard solution, 10 disposable plastic colorimetric cells (5cm), and 10 circular glass colorimetric cells (11mm) HACH liquid colorimeter LICO620
LMV187.99.20001 The following five ISO/ASTM color standards can be measured: Hazen/APHA/PtC color standard, Gardner color standard, Iodine color standard, Saybold color standard ASTM
D 1500 standard, wavelength range: 380-720nm, wavelength accuracy: ± 1.5nm (wavelength range 340-720nm), data storage: 400, display: color touch screen, interface: USB, Ethernet, power supply: 220VAC
Start Tool Kit LZM354
Containing chromaticity series standard solution, 10 disposable plastic colorimetric cells (5cm), and 10 circular glass colorimetric cells (11mm) GANIMEDEP total phosphorus automatic analyzer (36 position injection, with stirring function)
LPV401.99.00000 Range: 0.01-3.8mg/L, accuracy:<2% at 1mg/L, accuracy:<1%, display: LCD, power supply: 220VAC GANIMEDE control unit, 115V/230V
LQV135.99.00000 GANIMEDE automatic sampler (36 wells)
LQV134.99.10000 RS232-PC (LIMS) connection cable
LZV087 LACHAT TRANS software
LZV453 GANIMEDEP digestion analysis unit pipeline kit
LZV262 GANIMEDE automatic sampling unit pipeline kit
LZV263 GANIMEDEP Total Phosphorus Analysis Reagent
GCA100-CN GANIMEDEP cleaning solution
GCR100-CN GANIMEDE sample bottle (25mL)
LZQ035 GANIMEDE magnetic stirrer
LZQ045 GANIMEDE Total Phosphorus Automatic Analyzer (53rd injection)
LPV401.99.00000 Range: 0.01-3.8mg/L, accuracy:<2% at 1mg/L, accuracy:<1%, display: LCD, power supply: 220VAC GANIMEDE control unit, 115V/230V
LQV135.99.00000 GANIMEDE automatic sampler (53 wells)
LQV134.99.20000 RS232-PC (LIMS) connection cable
LZV087 LACHAT TRANS software
LZV453 GANIMEDEP digestion analysis unit pipeline kit
LZV262 GANIMEDE automatic sampling unit pipeline kit
LZV263 GANIMEDEP Total Phosphorus Analysis Reagent
GCA100-CN GANIMEDEP cleaning solution
GCR100-CN GANIMEDE sample bottle (15mL)
LZQ034 GANIMEDE Total Nitrogen Automatic Analyzer (36 bit injection, with stirring function)
LPV401.99.10000 Range: 0.5-30mg/L (low range), 30-150mg/L (high range), accuracy:<2% at 15mg/L, accuracy:<1%, display: LCD, power supply: 220VAC GANIMEDE control unit, 115V/230V
LQV135.99.00000 GANIMEDE automatic sampler (36 wells) LQV134.99.10000
RS232-PC (LIMS) connection cable LZV087
LACHAT TRANS software LZV453
GANIMEDEN digestion analysis unit pipeline kit LZV423
GANIMEDE automatic sampling unit pipeline kit LZV263
GANIMEDEN Total Nitrogen Analysis Reagent GCA200-CN
GANIMEDEN cleaning solution GCR200-CN
GANIMEDE sample bottle (25mL) LZQ035
GANIMEDE magnetic stirrer LZQ045
GANIMEDE Total Nitrogen Automatic Analyzer (53rd injection) LPV401.99.10000
Range: 0.5-30mg/L (low range), 30-150mg/L (high range), accuracy:<2% at 15mg/L, accuracy:<1%, display: LCD, power supply: 220VAC GANIMEDE control unit, 115V/230V
LQV135.99.00000 GANIMEDE automatic sampler (53 wells)
LQV134.99.20000 RS232-PC (LIMS) connection cable
LZV087 LACHAT TRANS software
LZV453 GANIMEDEN digestion analysis unit pipeline kit
LZV423 GANIMEDE automatic sampling unit pipeline kit
LZV263 GANIMEDEN Total Nitrogen Analysis Reagent
GCA200-CN GANIMEDEN cleaning solution GCR200-CN
GANIMEDE sample bottle (15mL) LZQ034 GANIMEDE total phosphorus/total nitrogen automatic analyzer (two sets of 36 position injection, with stirring function)
LPV401.99.00000 Range: 0.01-3.8mg/L, accuracy:<2% at 1mg/L, accuracy:<1%, display: LCD, power supply: 220VAC
GANIMEDE total phosphorus/total nitrogen automatic analyzer (two sets of 36 position injection, with stirring function) LPV401.99.10000
Range: 0.5-30mg/L (low range), 30-150mg/L (high range), accuracy:<2% at 15mg/L, accuracy:<1%, display: LCD, power supply: 220VAC GANIMEDE control unit, 115V/230V
LQV135.99.00000 GANIMEDE automatic sampler (36 wells)
LQV134.99.10000 RS232-PC (LIMS) connection cable
LZV087 LACHAT TRANS software
LZV453 GANIMEDEP digestion analysis unit pipeline kit
LZV262 GANIMEDEN digestion analysis unit pipeline kit
LZV423 GANIMEDE automatic sampling unit pipeline kit
LZV263 GANIMEDEP Total Phosphorus Analysis Reagent
GCA100-CN GANIMEDEP cleaning solution
GCR100-CN GANIMEDEN Total Nitrogen Analysis Reagent
GCA200-CN GANIMEDEN cleaning solution
GCR200-CN GANIMEDEP/N zero standard solution
GCZ100 GANIMEDEP/N low range standard solution
GCS050 GAIMEDEP/N high range standard solution
GCS100 GANIMEDE sample bottle (25mL)
LZQ035 GANIMEDE magnetic stirrer
LZQ045 GANIMEDE total phosphorus/total nitrogen automatic analyzer (one set of 36 position injection with stirring function; one set of 53 position injection) LPV401.99.00000
Range: 0.01-3.8mg/L, accuracy:<2% at 1mg/L, accuracy:<1%, display: LCD, power supply: 220VAC GANIMEDE total phosphorus/total nitrogen automatic analyzer (one set of 36 position injection with stirring function; one set of 53 position injection) LPV401.99.10000
Range: 0.5-30mg/L (low range), 30-150mg/L (high range), accuracy:<2% at 15mg/L, accuracy:<1%, display: LCD, power supply: 220VAC GANIMEDE control unit, 115V/230V
LQV135.99.00000 GANIMEDE automatic sampler (36 wells)
LQV134.99.10000 GANIMEDE automatic sampler (53 wells)
LQV134.99.20000 RS232-PC (LIMS) connection cable
LZV087 LACHAT TRANS software
LZV453 GANIMEDEP digestion analysis unit pipeline kit
LZV262 GANIMEDEN digestion analysis unit pipeline kit
LZV423 GANIMEDE automatic sampling unit pipeline kit
LZV263 GANIMEDEP Total Phosphorus Analysis Reagent
GCA100-CN GANIMEDEP cleaning solution
GCR100-CN GANIMEDEN Total Nitrogen Analysis Reagent
GCA200-CN GANIMEDEN cleaning solution
GCR200-CN GANIMEDEP/N zero standard solution
GCZ100 GANIMEDEP/N low range standard solution
GCS050 GAIMEDEP/N high range standard solution
GCS100 GANIMEDE sample bottle (25mL) LZQ035
GANIMEDE magnetic stirrer LZQ045
GANIMEDE sample bottle (15mL) 2569700
LZQ034 2812450 GANIMEDE total phosphorus/total nitrogen automatic analyzer (two sets of 53 position injection)
LPV401.99.00000 2608450 Range: 0.01-3.8mg/L, accuracy:<2% at 1mg/L, accuracy:<1%, display: LCD, power supply: 220VAC
GANIMEDE total phosphorus/total nitrogen automatic analyzer (two sets of 53 position injection) 2373250 LPV401.99.10000
Range: 0.5-30mg/L (low range), 30-150mg/L (high range), accuracy:<2% at 15mg/L, accuracy:<1%, display: LCD, power supply: 220VAC GANIMEDE control unit, 115V/230V
LQV135.99.00000 2569800 GANIMEDE automatic sampler (53 wells)
LQV134.99.20000 2101415 RS232-PC (LIMS) connection cable

LZV087 2101415 LACHAT TRANS software

LZV453 2182115

GANIMEDEP digestion analysis unit pipeline kit

LZV262 2101415
GANIMEDEN digestion analysis unit pipeline kit
LZV423 2560915

GANIMEDE automatic sampling unit pipeline kit

LZV263 GANIMEDEP Total Phosphorus Analysis Reagent GCA100-CN
GANIMEDEP cleaning solution GCR100-CN GANIMEDEN Total Nitrogen Analysis Reagent
GCA200-CN GANIMEDEN cleaning solution GCR200-CN
GANIMEDEP/N zero standard solution GCZ100 GANIMEDEP/N low range standard solution
GCS050 GAIMEDEP/N high range standard solution GCS100GANIMEDE sample bottle (15mL)
LZQ034 Laboratory BOD analyzer BODtrakII 2952400-CN
Range: 0-35, 0-70, 0-350, and 0-700mg/L, number of samples: 6 per time (473ml/bottle), operating temperature: 20 ℃, power supply: 220VAC Domestic biochemical incubator
Running Membrane filtration method portable microbiology laboratory MEL/MF
Total bacterial culture medium PK/50
Total coliforms/Escherichia coli culture medium PK/50 Fecal Escherichia coli culture medium
PK/50 The cigarette lighter
220V to 12V 15A 180W car cigarette lighter, car mounted inflation pump, high-power switch power converter
MEL/MPN Multi tube Fermentation Method Portable Microbial Laboratory Including: portable incubators, sampling bags containing chlorine removal agents, sterilization inoculation rings, and other necessary experimental equipment
Total coliform culture medium LTB (Initial Testing Medium), 15
Individual/package Escherichia coli culture medium
LTB (Initial Testing Medium), 15 Individual/package
Total coliforms/Escherichia coli culture medium LTB/MUG, 15 pieces/pack (4 packs per order)
Fecal coliform culture medium (drinking water) LTB (Initial Inspection Medium), 15 pieces/pack
Fecal coliform culture medium (wastewater) A-1 MEDIUM MPN TUBES, PK/15
COD-60A rapid oxygen consumption/permanganate index analyzer COD60A-2-6
Range: Standard: 9039700
0~20/40/100/200/400/1000mg/L, Arbitrary: 0~(10-2000mg/L can be set), dilution is required for concentrations above 0-200mg/L; Reproducibility: ± 2% FS, data storage: 100 data (measurement time, sample number, results), display: LCD, power supply: 220VAC Digital titrator on-site testing component - total hardness analyzer
2063600-CN Range: 10-160mg/L
CaCO3、100-4000mg/L CaCO3、1-16 G.d.h、10-100+ G.d.h 8760200
Digital titrator on-site testing component - acidity analyzer 2064000-CN
Range: 10-4000mg/L CaCO3 On site testing component of digital titrator - alkalinity/total alkalinity analyzer
2063700-CN Range: 10-4000mg/L CaCO3
On site testing component of digital titrator - chloride analyzer 2063500-CN
Range: 10-8000mg/L CL -
Titralab 1000 potentiometric automatic titrator AT1222.97
2 burettes, 2 pumps PH/alkalinity in water
AP0001.AT1102 PH/Alkalinity/Conductivity Analysis Package for Water AP0002.AT1102
Free chlorine and total chlorine dioxide sulfite 8760200
AP0007.AT1122 Total hardness in water (colorimetric) AP0004.AT1112
5 to 400 mg/L (Max. 9039700 800 mg/L) of CaCO3
PH/Alkalinity/Hardness in Water (ISE) AP0005.AT1222
Chloride ions in water AP0009.AT1112
Karl Fischer Moisture Analyzer (Volumetric Method) Host KF1121.97 Moisture analysis package
AP0014.KF1121 Conventional water quality five parameter HL4 host with internal battery compartment
HL4TABATT PH reference 2-in-1 probe HLPHIREF
Turbidity probe HL4TURB
Conductivity probe HLCOND
Optical dissolved oxygen probe HLLDO
25 meter depth probe HL25MDEPTH RS485 Modbus Communication Module

IP67 waterproof hand reader 32687
SVRHL 10 meter underwater cable
CZ010 31270
AC power adapter. 90-264V AC, 47 to 63 Hz, 12V 32015.020
HL7 host with built-in battery compartment and temperature probe HL7TABATT
Freshwater blue-green algae probe, stainless steel casing 32746
HLBGRNA 32747
Chlorophyll probe, stainless steel casing 32688
HLCHLOR Self cleaning turbidity probe, including central cleaning brush
HLTURB_SC_BRUSH 31230.01
Conductivity probe 32001.010
HLCOND 32723
PH matched standard reference electrode 32512.03
HLPHSREF 32687
Optical dissolved oxygen probe HLLDO
IP67 waterproof hand reader with built-in pressure sensor SVRHL If online monitoring is required, there is no need for it
AC power adapter. 90-264V AC, 47 to 63 Hz, 12V
5-meter underwater cable
CZL005
Cable length optional RS485 Modbus Communication Module If portable measurement is needed, there is no need for it
Portable water quality sampler AS950 ASP.CXRXS141XX Battery Charger
8753500EU
Portable water quality sampler AS950 ASP.CXXXS141XX 1. 926 filter made of polytetrafluoroethylene/stainless steel; 2. 920 25 foot ethylene inlet pipeline with an inner diameter of 3/8 foot; 3. PS241000 24 1L sampling bottles; 4. 8754400 12V lead-acid battery; 5. Data cable; 6. One instruction manual
Battery Charger
8753500EU Portable dissolved oxygen meter Orbisphere3655 3655/111
Trace oxygen ppb (μ g/L) Electrochemical sensor for measuring dissolved oxygen GA2400-S00
Flow pool, 1-meter tube 32007D Maintain spare parts
2956A-A-CN adapter
32051A Adapter (to ensure seamless connection between on-site sampling port and flow cell injection tube) is generally not equipped. When the cable is separate, adapter, 3-meter cable, electrochemical cleaning and regeneration tool - these three items are generally not equipped Software and communication cables
Portable dissolved hydrogen meter host Orbisphere3654 3654/210R Thermal conductivity sensor, measuring dissolved hydrogen
flow-through cell 9450000 Blow gas adapter
32824A 9467100 Maintenance spare parts, including 29561A, membrane positioning ring, O-Ring, Tools
Maintenance spare parts, including 2952A, membrane positioning ring, O-Ring, Tools 9459400
Software and communication cables 9459500
Portable dissolved hydrogen meter host Orbisphere 9459700
3655/210
electrochemical sensor 2672700
flow-through cell
Maintenance toolkit 3-meter cable
Software and communication cables Electrochemical cleaning and regeneration tools
32301.B Portable dissolved oxygen detector Orbisphere
DGK3100-MI2040 Response time: (t90)<>
Principle: Fluorescence method Range: 0-2000 ppb Accuracy: ± 0.8 ppb or ± 2%
Portable Pure Water Conductivity Analyzer CM31PW CM31PW-1-1B Including electrode CT-27111D (electrode constant 0.01/cm, range 0.05 μ s/cm~0.2ms/cm) and flow cell
Conductivity verification solution OBI00001 Electrical