New large capacity turbo molecular pump
By equipping with a new ultra efficient large capacity turbo molecular pump, the instrument performance of helium, hydrogen, and nitrogen as carrier gases is further improved. The differential vacuum system using an ion source and a quadrupole mass analyzer for exhaust can ensure optimal mass spectrometry under any carrier gas conditions.
Pesticide quality chromatogram (5 μ g/L, SIM mode, hydrogen as carrier gas)
High performance ion source
The patented high brightness ion source can obtain analysis results with high sensitivity and stability. No need to replace the ion source, easily switch between ionization modes. The new "Quick CI" function can quickly obtain molecular ions of compounds using CI mode, further enhancing the accuracy of qualitative information. Utilize the limits of mass spectrometry analysis in both quantitative and qualitative aspects.
Usually, it is difficult to obtain molecular ions of compounds using EI ionization method. Quick CI function can be used to quickly switch to CI ionization method for data acquisition and obtain relevant information.
The EI mass spectrum (left) and CI mass spectrum (right) of the hydrochloride standard substance belonging to cathinone (3,4-methylenedioxyphenylmethylpentanone)
High performance gas chromatograph
Advanced Scanning Speed Protocol (ASSP) for high-speed scanning control technology ™)
Automatically optimizing the bias voltage of the quadrupole during high-speed data acquisition effectively suppresses the decrease in sensitivity during scanning above 10000u/sec. Compared with traditional instruments, the sensitivity is increased by more than 5 times. Especially in Fast GC/MS analysis, FASST analysis for synchronous data acquisition of Scan and SIM, and the application of GC × GC-MS, the sensitivity of scan data and the accuracy of mass spectrometry are significantly improved. (Patent: US6610979)
Changes in chromatogram intensity at different scanning speeds
At scanning speeds above 10000u/sec, the ASSP function is utilized to accelerate ions at the optimal voltage while maintaining ion signal strength, suppressing signal strength degradation across the entire mass range.
Intelligent software GCMS Insight
Simplified multi-component analysis method
The automatic method creation function "Smart SIM" can automatically generate the best SIM analysis conditions based on retention time. In cases where multiple methods are required to analyze a large number of compounds, the "Smart SIM" function can be used to simplify the development of methods without affecting sensitivity. Significantly reducing the number of analyses, shortening experimental time, and significantly improving work efficiency.
Support the simultaneous use of Smart SIM database and GCMS analysis methods.
Compared with traditional grouping methods, the Smart SIM grouping method can achieve high sensitivity and accuracy in quantitative results. When analyzing 434 trace compounds, excellent reproducibility and precise standard curves can also be obtained, significantly improving detection capability.
LabSolutions Insight intelligent multi data analysis software
Improve the efficiency of multi data analysis
Through LabSolutions Insight software, it is possible to output quantitative values and QC results of sample files side by side. Overview of chromatograms of all specific target substances, intuitive inspection and evaluation of sample information, and improvement of multi data analysis experience. The color labeling function can quickly identify outliers in the sample and re audit the results.
Intuitive data accuracy management
Multi client system
Users can remotely browse the data results of samples and perform remote diagnosis through a client computer via LAN or other network methods. In a multi client system, any client can be used for experimental analysis and verification of data results. The system has experimental analysis and data processing units to meet the work needs of different operators and significantly improve work efficiency.