Provide professional magnetic field measurement solutions | ||||||
Strong magnetic field measuring instrument(0 - 20T) | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
X113 |
hall |
hall sensor |
1 |
<> |
15T |
TC: 30ppm/K |
G80 |
hall |
handheld |
1 |
2% |
2T |
10μT |
G81 |
hall |
handheld |
1 |
0.8% |
10T |
1μT |
G82 |
hall |
handheld-high frequency |
1 |
0.8% |
10T |
1μT |
G83 |
hall |
handheld |
3 |
0.8% |
10T |
1μT |
G92 |
hall |
handheld |
1 |
1% |
10T |
10μT |
G93 |
hall |
handheld |
3 |
1%, 0.5% |
20T |
1μT |
G201 |
hall |
Desktop computer |
1 |
0.2% |
10T |
1μT |
G203 |
hall/reluctance |
Desktop computer |
3 |
0.2% |
10T |
10nT |
G401 |
hall |
Desktop computer |
1 |
0.04% |
10T |
1μT |
G403 |
hall |
Desktop computer |
3 |
0.04% |
10T |
1μT |
GSP301A |
hall |
Analog transmitter |
1 |
1%, 0.2% |
10T |
Output: ±3V |
GSP301D |
hall |
Digital transmitter |
1 |
1%, 0.2% |
10T |
1μT |
GSP303D |
hall |
Digital transmitter |
3 |
1%, 0.2% |
20T |
1μT |
GSP303D-S |
hall |
Digital transmitter |
3 |
0.5%, 0.1% |
3T |
1μT |
Magnetic field testing system | ||||||
GAS3000 |
Array magnetic field detection system, synchronous detection up to128The magnetic field at a certain location |
|||||
GMS980 |
High precision Gaussian meter calibration system (High precision Tesla meter calibration device) |
|||||
Weak magnetic field measuring instrument(0- 2mT) | ||||||
Weak magnetic field Gaussian meter | ||||||
model |
principle |
type |
number of axles |
DCaccuracy |
maximum range |
Highest resolution |
GMR61 |
reluctance |
handheld |
1 |
0.8% |
600μT |
10nT |
GMR63 |
reluctance |
handheld |
3 |
0.8% |
600μT |
10nT |
GF601 |
fluxgate |
handheld |
1 |
0.5% |
1mT |
0.1nT |
GF603 |
fluxgate |
handheld |
3 |
0.25% |
1mT |
0.1nT |
GF633 |
fluxgate |
Desktop computer |
3 |
0.1% |
100μT |
0.01nT |
GFP703 |
fluxgate |
Smart Transmitters |
3 |
0.5% |
1mT |
0.1nT |
GFP703S |
fluxgate |
Spectrum analyzer |
3 |
0.5% |
1mT |
0.01nT |
GFP803 |
fluxgate |
Smart Transmitters |
3 |
0.2% |
1mT |
0.1nT |
Communication magnetic field measurement(DC- 1MHz) | ||||||
model |
principle |
type |
number of axles |
ACaccuracy |
maximum range |
frequency response |
AMS-2K |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
30Hz- 2kHz |
AMS-1M |
alternating current coil |
Analog sensor |
1 |
1% |
3mT |
2kHz- 1MHz |
G1000 |
reluctance |
Smart Transmitters |
3 |
DC- 1% AC- 2% |
400μT/ Axis |
DC- 1MHz |
GA1000 |
reluctance |
handheld |
3 |
2% |
400μT/ Axis |
30Hz- 1MHz |
GSP301HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
GSP303HFA |
reluctance |
Analog transmitter |
1 |
1% |
150μT |
20Hz-1.2MHz |
fluxgate sensor | ||||||
model |
principle |
type |
number of axles |
noise level |
maximum range |
output |
F901 |
fluxgate |
Economic type |
3 |
10 to 20pT |
1000μT |
±10V,single-ended |
F902 |
fluxgate |
low noise |
3 |
<> |
100μT |
±10V,single-ended |
F903 |
fluxgate |
low-power consumption |
3 |
10 to 20pT |
200μT |
±3V,finite difference |
F904 |
fluxgate |
low-power consumption|low noise |
3 |
<> |
100μT |
±3V,finite difference |
F905 |
fluxgate |
high-performance|low noise |
3 |
<> |
100μT |
±10V,single-ended |
F23 |
fluxgate |
split type|large range |
3 |
<> |
1500μT |
±10V,single-ended |
F53 |
fluxgate |
High temperature type |
3 |
≤ 300pT@175℃ |
100μT |
±5V,finite difference |
Magnetic flux gate sensor data acquisition unit | ||||||
FDU301 |
Connectable1A three-axis flux gate sensor |
|||||
ASA1000 |
Connectable2-126A single axis flux gate sensor or2-42A three-axis flux gate sensor |
|||||
AFS |
Array flux gate sensor detection system, capable of connecting multiple flux gate magnetic field transmitters |
|||||
GMR-16 |
Micro weak magnetic field sensor array, capable of synchronous acquisition2-16Data from a miniature weak magnetic field sensor |
|||||
GR100 |
Digital three-axis flux gate gradiometer |
|||||
remarks: 1Magnetic field unit conversion:1T= 10kG; 1mT= 10G; 1μT= 10mG; 1nT= 10μG 2Click on the left side of the table abovemodelYou can refer to the product information of the corresponding model |
sketch:
G403The 3D Gaussian meter is a device that utilizesCOLIYThe company's third-generation semiconductor gallium nitride(GaN)High precision desktop 3D Gaussian meter with Hall sensor. Gallium nitride sensors have the characteristics of good temperature stability, not affected by light, high linearity, and low noise, and their performance is ahead of the second-generation semiconductor gallium arsenide(GaAs)Sensor technology.
Ordinary Gaussian meters require frequent zero calibration during start-up and measurement, which is cumbersome to operate and affects accuracy.G403The three-dimensional Gaussian meter adoptsBypass Zero TechnologyProprietary technology and high stabilityGaNHall sensors are ready to use upon startup, without the need for zero calibration, greatly improving data accuracy and user convenience.
G403The three-dimensional Gaussian meterDCAccuracy better than0.04%, with a range of up to100kG(10T)Frequency response rangeDC-10kHz.G403The three-dimensional Gaussian meter has up to7The display number of bits has extremely low measurement noise throughout the full range, typicalDCMagnetic field noise0.01G(1μT).
G403The three-dimensional Gaussian meter adopts10.1Inch color industrial resistance touch screen, built-in graphical interface operating system, easy to operate, users can use it without reading the manual; Adopting aviation aluminum alloy shell, small size, saving desktop space, low-power fanless design, green and environmentally friendly.
G403The three-dimensional Gaussian meter is powerful and has the maximum value/Minimum value, vector value, andXYZComponent value, magnetic field polarity display, storage, time-domain graph, oscilloscope, real-time spectrum analysis, and0.2msPulse magnetic field capture function;G403The three-dimensional Gaussian meter has rich measurement modes:DCStandard modeDCTime domain patternXYZ3D modeACStandard modeACSpectrum analysis modeACOscilloscope mode and0.2msPulse magnetic field mode, suitable for various complex magnetic field measurement scenarios.G403Three dimensional Gaussian meter using Fourier analysis to measure AC magnetic fieldRMSValue, frequency response range0.5Hz-10kHz,Suitable for measuring magnetic fields of sine waves, square waves, triangular waves, trapezoidal waves, sawtooth waves, and other waveforms.
Users can choose from multiple probes: radial probe, axial probe, 3D probe, and probe with temperature compensation. The thickness of the micro 3D probe and the micro axial probe is only1mmIt is a unique product of our company. The temperature coefficient of a conventional probe is±100ppm/℃The temperature coefficient of the probe with temperature compensation is only±20ppm/℃It is currently one of the probes with the lowest temperature coefficient on the market. It can greatly improve measurement accuracy and stability during temperature changes, so it is strongly recommended to purchase probes with temperature compensation.
G403The 3D Gaussian meter has passedCECertification andEMC(electromagnetic compatibility)Testing.
characteristic | |
●Free from school and zero technology ●Graphical interface operating system ●Third generation semiconductorGaNhall sensor ●10.1inchLCDcolorful touch screen ●RMSExchange various waveform magnetic field measurements ●measureRMSThe communication magnetic field is as low as0.5Hz ●up to7Number of digits displayed ●Aviation aluminum shell design, saving desktop space ●Low power fanless design, green and environmentally friendly |
●Range up to100kG (10T) ●typicalDCmagnetic fieldnoise0.01G (1μT) ●DCaccuracy0.04% ●frequency responseDC- 10kHz ●After compensationtemperature coefficient±20ppm/℃ ●Vector values andXYZComponent value function ●Maximum value/Minimum value function ●0.2msPulse magnetic field capture function ●Real time spectrum analysis function |
G403Gauss meter parameters:
model |
G403 |
Measurement parameters | |
accuracy(DC , 25℃) |
±0.04% |
accuracy(AC , 25℃) |
±1% FS |
range |
100kG (10T) |
Highest resolution |
0.01G (1uT) |
Host frequency response range |
DC - 10kHz |
typicalDCMagnetic field noise |
0.01G (1uT) |
Measurement mode
|
1DCStandard: Display current measurement mode, real-time value, magnetic field polarityN/SMaximum value, minimum value, alarm threshold; 2DCTime domain diagram: display800 Trend chart of magnetic field variation over time within seconds; 3XYZ3D: Display the current measurement mode, vector valuesXYZComponent value and alarm threshold; 4ACStandard: Communication frequency response range0.5Hz-10kHz, RMSRoot mean square value, suitable for various waveforms such as sine wave, square wave, triangular wave, trapezoidal wave, sawtooth wave, etc; 5ACSpectral analysis: Fourier analysis20Hz-10kHz,Display graph and3The maximum magnetic field peak and frequency value; 6ACOscilloscope: Real time display up to5kHzMagnetic field waveform or high-frequency noise disturbance; 7Pulse magnetic field measurement: capable of capturing time width>0.2msThe positive and negative pulse magnetic fields have a maximum pulse magnetic field value of up to10T. |
Display digits |
complete7Position, maximum99999.99G |
Host storage capacity |
>8000A data |
zero drift |
useBypass Zero TechnologyProprietary technology, no zero drift, temperature and hysteresis have no effect on zero. |
Probe temperature coefficient |
<>℃(Conventional probe) <>℃(Equipped with temperature compensation probe) |
display | |
display screen |
10.1Inch color resistive touch screen,1024x600pixel |
Units of magnetic field |
Gaussian(G)Tesla(T) |
Display update rate |
4order/second |
display mode |
DC、ACMaximum value, minimum value, alarmN/SMagnetic pole display, spectrum analysis0.2msPulse magnetic field capture, time-domain graph, oscilloscope, etc |
probe | |
sensor |
COLIYThird generation semiconductor gallium nitride(GaN)hall sensor |
Compatible probes |
details“Probe specifications”list |
connector |
IP67Waterproof connector |
Probe handle and protective cover |
Non magnetic aviation aluminum alloy, resistant to5Rice Drop |
Cable line |
Shielded twisted pair flexible cable, compliant withCAT5estandard |
Cable Length |
standard1.5Rice; Customizable maximum length30rice |
USBinterface | |
function |
1Communication: used to connect to computers, display measurement data, etc; 2Power supply: used for connection5VDCCharger or portable power bank(power bank). |
software/drive |
Equipped with upper computer software/supportLabVIEW ™ |
Analog Output | |
Linearity(DC) |
±0.1% |
function |
Real time output, output voltage proportional to magnetic field strength |
Full range voltage |
±5 V |
output scaling |
6Optional files(x1, x2, x4, x8, x16, x32) |
Frequency response range |
Refer to the frequency response parameters of the probe |
connect |
Dedicated analog outputBNCConversion cable |
Host specifications | |
storage temperature |
- 25℃~ +60℃ |
operation temperature |
-20℃~ +50℃ |
preheat |
Ready to use upon startup. preheat5Achieve optimal performance in minutes |
Host temperature coefficient |
<±10ppm>±10ppm>℃Neglecting the impact on accuracy within the working temperature range |
Environmental magnetic field |
<1kg(0.1t) =''>1kg(0.1t)> |
power supply |
5VDC, can be connected to a portable power bank for power supply |
power interface |
Type-C USB |
size(Excluding detachable base) |
281 mm W × 164 mm H × 26 mm D |
weight |
1.52kg |
material |
High strength aviation aluminum alloy |
authentication |
CECertificationEMCauthentication |
Probe specifications
G4033D Gaussian meter probe | |||||||
probe Type |
range |
highest resolution |
Frequency response range |
Probe rod size (mm) |
operation temperature (℃) |
DCaccuracy (25℃) |
Surface material of probe rod |
Standard 3D probe Y08M150G403 Y08M150G403T |
100kG (10T) |
0.01G (1μT) |
DC-10kHz |
75*5.7*2.5 |
-20 - +60 |
±0.1% Reading ± 0.01% FS |
copper |
Micro 3D probe Y04S150G403 Y04S150G403T |
100kG (10T) |
0.01G (1μT) |
DC-10kHz |
45*2.2*1 |
-20 - +60 |
±0.3% Reading ± 0.03% FS |
copper |
Metal radial probe T08M150G403 T08M150G403T |
100kG (10T) |
0.01G (1μT) |
DC-10kHz |
80*2.2*1 |
-20 - +60 |
±0.04% Reading ± 0.01% FS |
copper |
Plastic radial probe T08P150G403 T08P150G403T |
100kG (10T) |
0.01G (1μT) |
DC-10kHz |
80*2.5*1.3 |
-20 - +60 |
±0.04% Reading ± 0.01% FS |
plastics |
Standard axial probe A08M150G403 A08M150G403T |
100kG (10T) |
0.01G (1μT) |
DC-1kHz |
80*Φ6 |
-20 - +60 |
±0.1% Reading ± 0.01% FS |
copper |
Miniature axial probe A04S150G403 A04S150G403T |
100kG (10T) |
0.01G (1μT) |
DC-1kHz |
45*2.2*1 |
-20 - +60 |
±0.3% Reading ± 0.03% FS |
copper |
Note:
1The model number ends with a letter“T”Probe with built-in temperature sensor, equipped with temperature compensation function, and its temperature coefficient<±20ppm>±20ppm>℃;
2The complete calibration range of each probe:≤±2T(±20kG);
3The size and surface material of the probe, as well as the length of the cable, can be customized.
Optional Accessories
type |
describe |
ZC10 |
School zero cavity: in500GIn the following magnetic fields, up to80Decibel attenuation, used for zero calibration of standard probes. Internal dimensions of the cavity: diameter6.8mmx 44.5mm |
PS-1W |
Mobile power bank, can be used asG401The external power supply of the Gauss meter, throughUSBInterface power supply. Capacity:10000mAh; Output:5V/2A |
SAMRT PC Software |
Computer software for Gauss meter(Comes with the instrument) |
GHOLD100 |
The three-dimensional mobile platform of the probe is made of non-magnetic materials. The user fixes the probe at the front end of the bracket and manually rotates the knob to make the probe move alongX, Y, ZMove steadily in the axial direction to a certain position and lock it in place. The maximum stroke of each axis is150mmThe positioning accuracy is0.1mmCentral load10kg, self weight3.5kg |
Probe cable extension cable |
The longest customizable length30Rice. |
The most commonly used kit |
Kit Product NumberG40301Gaussian meter hostG403 +3D probeY08P150G403 |
Probe selection type description
Y |
08 |
P |
150 |
G403 |
T |
probe Type A -Axial probe T -radial probe X - 2 AXIS Y - 3 AXIS
|
Probe length 06 - 6 cm 08 - 8 cm 10 - 10 cm 25 - 25 cm
… |
Probe style C – CRYOGENIC F – FLEXIBLE L – LOW FIELD M – METAL P – PLASTIC S – SMALL SIZE U – ULTRATHIN W – WIDE FIELD |
Probe cable length 150 – 3750px … |
Gaussian meter type G403 – G403 probe
|
Temperature compensation function (Probe with built-in temperature sensor) T -have BLANK -not have |