Five star motor M16 product picture:
Model (Type) | displacement | Torque (N.m) | Pressure (MPa) | speed range | weight | ||
(ml/r) | Torque(Rated) | Theoretical torque per unit(N.m/MPa) | Rated pressure(Rated) | Maximum pressure(Max) | (r/min) | (kg) | |
M16-1400 | 1415 | 5228 | 203 | 25 | 32 | 2-400 | 170 |
M16-1600 | 1645 | 4876 | 244 | 20 | 25 | 2-400 | |
M16-1800 | 1815 | 5368 | 266 | 20 | 25 | 2-350 | |
M16-2000 | 2003 | 5414 | 308 | 16 | 22.5 | 2-350 | |
M16-2400 | 2267 | 5369 | 331 | 16 | 20 | 2-250 |
Five star motor M16 performance:
Installation size:
Five star motor M16 product features:
1. Easy to install. (Common and special installation connection sizes are allowed)
2. The rotation direction of the output shaft can be adjusted in both forward and reverse directions. (The output shaft can withstand radial and axial external forces)
3. Less leakage and simple maintenance. (Adopting a compensable end face flow distribution structure)
4. High volumetric efficiency. (Using new technology to seal the piston and cylinder body)
5. Excellent low-speed stability performance. (Starting mechanical efficiency greater than 0.9)
6. The noise is very low. (Adopting a crankshaft and a five cylinder piston structure with low excitation frequency)
Instructions for using five-star motor M16:
1. Please check the integrity of the hydraulic motor before use. If it has not been used continuously for a long time, please replace it with clean hydraulic oil and fill the chamber in a timely manner.
2. Random installation of hydraulic motors is allowed, but they must be coaxially connected to the load.
3. Before the first use, the hydraulic motor chamber must be filled with clean hydraulic oil, and the drain port should be placed on the highest horizontal line of the entire hydraulic motor. At the same time, the drain pipe should directly lead to the oil tank.
4. Recommended industrial filtration accuracy is 25 microns. In special working conditions, the filtration accuracy can also be 75 microns, and the viscosity must be ensured to be between 15-1000cs.
5. To extend the service life, it is necessary to avoid radial and axial external force loads on the output bearing as early as possible.