Zibo Botong Fan Co., Ltd
Home>Products>FBCZ (BK54) coal mine explosion-proof extraction fan
FBCZ (BK54) coal mine explosion-proof extraction fan
FBCZ (BK54) coal mine explosion-proof extraction fan
Product details


The materials used for the explosion-proof extraction type axial flow fan have passed the friction spark test of the Chongqing Branch Testing Center of the Chinese Academy of Coal Sciences and met the explosion-proof requirements. The explosion-proof performance of the whole machine has passed the explosion-proof inspection of the National Explosion proof Electrical Product Quality Testing Center.

Main features:


1. The simplest structure of the fan, which adopts a direct connection between an electric motor and an impeller, has changed the current coal mine extraction type axial flow ventilation and the complex structure of using belt drive or long shaft drive, which is conducive to operation and maintenance.


2. The FBCZ series explosion-proof extraction axial flow fan for coal mines is equipped with a fully enclosed and pressure resistant heat dissipation cover and pressure balance pipe outside the motor, ensuring that the motor always operates in gas free air and meets the requirements of relevant explosion-proof regulations for coal mines.


3. The FBCZ series explosion-proof extraction axial flow fan for coal mines is a single-stage working wheel structure, with a rear guide vane installed between the fan and the diffuser to improve static pressure efficiency.


4. The fan can reverse the reverse air flow, with a reverse air volume of up to 65% to 85% of the positive air volume. There is no need to set up a separate reverse air duct, which has the advantages of saving infrastructure investment and fast reverse air speed.


5. The installation angle of the impeller blades can be adjusted according to production requirements. The fan adopts a special design, with no hump in the performance curve, and can operate stably under any network resistance.


Technical performance parameters table of FBCZ series (formerly BK54 series) explosion-proof extraction axial flow fan for coal mines:


model Speed (r/min) Airflow (m3/s) Wind pressure (Pa) Equipped with motor power (kw)
FBCZ-4-No8 1450 2.5~7.4 173~631 5.5
FBCZ-4-No9 3.5~10.5 219~799 11
FBCZ-4-No10 4.8~14.4 270~986 15
FBCZ-4-No11 6.4~19.2 327~1193 30
FBCZ-4-No12 8.3~24.9 389~1420 45
FBCZ-4-No13 10.6~31.7 475~1667 55
FBCZ-6-No10 980 3.2~9.7 123~450 7.5
FBCZ-6-No11 4.3~12.9 149~545 11
FBCZ-6-No12 5.6~16.7 177~648 15
FBCZ-6-No13 7.0~21.3 208~761 22
FBCZ-6-No14 8.8~26.6 241~882 30
FBCZ-6-No15 lO.8~32.7 277~1013 45
FBCZ-6-No16 13.1~39.7 315~1152 75
FBCZ-6-No17 15.7~47.7 355~1301 90
FBCZ-6-No18 18.7~56.6 399~1458 110
FBCZ-6-No19 21.9~66.5 444~1625 132
FBCZ-8-No16 730 9.8~29.6 175~639 30
FBCZ-8-No18 14.0~42.1 221~809 55
FBCZ-8-No20 19.1~57.8 273~998 90
FBCZ-8-No22 25.5~76.9 331~1208 160
FBCZ-8-No24 33.1~99.9 394~1438 220
FBCZ-8-No26 42.1~127.0 462~1687 355
FBCZ-10-No20 580 15.2~45.9 172~630 55
FBCZ-10-No22 20.2~61.1 208~762 75
FBCZ-10-No24 26.3~79.3 248~907 110
FBCZ-10-No26 33.4~100.8 29l~1064 160
FBCZ-10-No28 41.7~125.9 337~1234 250
FBCZ-10-No30 51.3~154.9 387~1418 355
FBCZ-10-No32 62.3~188.0 440~1613 450

The above is a detailed introduction about FBCZ (BK54) coal mine explosion-proof extraction fan manufacturer, FBCZ (BK54) coal mine explosion-proof extraction fan price, FBCZ (BK54) coal mine explosion-proof extraction fan supply, FBCZ (BK54) coal mine explosion-proof extraction fan manufacturer, and FBCZ (BK54) coal mine explosion-proof extraction fan sales
Regional products:
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!