Compact research microscope with excellent optical performance
With proven optical and mechanical design techniques, Nikon has launched a compact high-performance structureECLIPSE CiSeries of upright research microscopes. By using high-quality objective lenses and specialized epifluorescence attachments, bright high contrast fluorescence images can be presented. When the microscope is paired with NikonDigital SightWhen used in conjunction with a series of cameras, specimen shooting becomes easy and efficient. In addition, newly developed high brightness can also be installedLEDThe lighting device has multiple electric components and excellent ergonomic design, allowing for comfortable posture for observation and photography.ECLIPSE CiThe series microscope, with its excellent optical performance, sophisticated ergonomic design, and easy advanced control, can support a variety of research applications.
|Automatic magnification switching (Ci-E)
This model is equipped with electric magnification switching and automatic reproduction of light intensity, which is very suitable for various applications that require frequent switching of magnification.
•Objective lens converter rotation button
Simply press lightly to switch the objective lens. Additionally, you can customize two commonly used magnification ratios by simply pressing this button to switch between these two objectives.
Objective switching button
• Remote control
After setting a specific button to correspond with a specific objective lens, simply press it lightly to easily change the magnification.
control panel
• Automatic reproduction of lighting intensity
The light intensity defined by the user for each objective lens will be automatically memorized and recalled the next time the objective lens is used, eliminating the hassle of manual adjustment again.
• Environmentally friendly lighting(Ci-E、Ci-L)
By using collimating lenses, compound eye optics, andLEDIllumination can also obtain bright and uniform images at the edges of the image. usedLEDLong lifespan, low power consumption, can reduce the number of bulb replacements, and provide the same color temperature at all magnifications. (Patent application in progress)
| Ergonomic Design
The variety of accessories is abundant, allowing users to observe and capture images in a comfortable posture.
Ergonomic binocular tube
Can adjust the angle of the eyepiece(10° - 30 °)The eyepiece can be extended (up to)40 mm). Can be achieved throughDSCPort installation camera.
•Eye point lifter
Can be improved25mmEye point height to fit the posture typically adopted by the user.
•A cargo platform with adjustable handle height
Easily move the stage by placing your hands in a comfortable position.
•Lower the position of the loading platform
The height of the stage can be lowered from the standard position through the lens converter gasket20 mmTo facilitate easy specimen replacement while maintaining a comfortable posture.
| Enhanced digital imaging operability
ECLIPSE CiSeries microscopesDigital SightSeries imaging systems andNIS-ElementsImaging software supports intelligent image capture with more powerful features.
•Image capture button
Just press the button on the microscope base lightly to makeDigital SightThe series of cameras has completed shooting.
•Digital Sight DS-L3 Camera Control Unit
An independent controller equipped with a large-sized display screen can directly capture images without the need for a computer. By using the scene mode icon on the touch screen to select the observation method, it can be completedDigital SightEasy setup and operation of the camera. Simple measurement functions such as measuring the distance between two points can be used. In addition, objective lens switching andCi-ESpotlight setting. Through network functionality, it is possible to remotely monitor multiple devices during the observation periodPCShare real-time images online.
|Multiple observation methods
ECLIPSE Ci-L/Ci-EAdopting high brightness environmentally friendly lighting, it can provide sufficient contrast and simple polarization observationThe intensity of the light. Through a variety of accessories, users can perform various observation modes, including fluorescence observation.
•Difference
Regardless of the magnification range, high contrast images with neutral background colors can be obtained. This observation method is suitable for observingExamine structures without staining.
Differential attachments and objective lenses
•Dark field of view
Clear observation of the subtle structures of blood or flagella is possible. Dry and oil type spotlights can be used. The use of beam expanderHigher brightness lighting can be obtained.
•Simple polarization
Very suitable for observing birefringent specimens such as collagen, amyloid, and crystals.Dihydrocarbon adenine crystal simple polarizing attachment
•Sensitive color polarization
By changing the interference color, the formation of uric acid crystals in organisms can be identified, which is very suitable for testing gout and pseudogout.
Sodium urate crystal sensitive color polarizing attachment
•Epifluorescence
The compact epifluorescence attachment adoptsCiA series of specialized noise cancellation devices that capture fluorescent images with brightness, contrast, and signal-to-noise ratio(S/N)High. The filter block turntable can accommodate up to four filter blocks, making replacement very simple. The name and location of the filter block are located on the fluorescent label in front of the attachment, which can be easily identified even in dimly lit rooms. The filter or dichroic mirror in the filter block can be easily replaced to flexibly match various combinations.
Fluorescent Attachment