Eltra, Germany launched the new ELEMENTRAC ONH-p series in 2016 for precise and reliable measurement of oxygen, nitrogen, and hydrogen elements. The newly designed sample dropping device is more powerful and wear-resistant, so the measurement results of standard samples and granular samples without capsule wrapping are more accurate and reliable. The new software design menu structure of ELEMENTRAC ONH-p is clearer, not only supporting export function, but also capable of segmented leak detection.
Eltra, Germany launched the new ELEMENTRAC ONH in 2016-pThe series is used for precise and reliable measurement of oxygen, nitrogen, and hydrogen elements. The newly designed sample dropping device is more powerful and wear-resistant, so the measurement results of standard samples and granular samples without capsule wrapping are more accurate and reliable. So ONH-pSuitable for more routine analysis and research and development processes.
The ONH series has always adhered to humanized design. Chemical reagents need to be replaced frequently, so the reagent tube is placed in front of the analyzer for easy operation, while it is hidden behind the door during the analysis process. ELEMENTRAC ONH-pThe new software design has a clearer menu structure, which not only supports export functions but also enables segmented leak detection.
ELEMENTRAC ONH-pYou can freely choose the combination of elements for analysis. In addition, gas purification and gas calibration accessories can also be selected.
High performance inert gas melting furnace
Reliable analysis of oxygen, nitrogen, and hydrogen elements
The newly designed closed gas path optimizes the gas path circulation, making the measurement of oxygen, nitrogen, and hydrogen content more accurate
√ Cheaper argon gas can be used as the carrier gas
The newly designed catalytic furnace can adjust the reaction temperature to make oxygen measurement more accurate
The newly designed software has more powerful functions:
-Segmented leak detection is possible
-Enhanced the statistical function of data
-User friendly fault diagnosis function that can monitor the real-time operation of the instrument
Technical Parameter
ONHAnalyzer ELEMENTRAC ONH-p
Measurement range: 1g sample
Oxygen: 0.1ppm-2%
Nitrogen: 0.1ppm-2%
Hydrogen: 0.01ppm-1000ppm
General parameters
Analysis time: nominal 150s
Correction: Solid standard sample, gas standard sample
Detection: O2Infrared absorption
N2/H2Thermal conductivity pool
Sample shapes: needle shaped, granular, linear, powdery
Reagent: Magnesium perchlorate
-Sodium hydroxide
-Copper oxide
-Schutze reagent
Power supply: 400V, three-phase
Single phase can be requested
Optional: - Gas Calibration
-External cooler
-Gas purification device
Carrier gas: - argon 99.995% (ON/OH type)
-Helium 99.995% (ON type)
-Nitrogen 99.995% (OH type)
-Compressed air (2-4 bar)
Interface: USB
Cooling: - External cooler
-Cooling container
*The measurement range varies depending on the selected configuration