E+H original imported intelligent capacitor level gaugeThe integrated transmitter can operate normally in minimum or maximum fail safe mode. Its sturdy and durable mechanical structure, verified through testing, ensures that the probe can accurately measure under strong tensile loads (≤ 60KN for cable probes) or strong lateral loads (≤ 300Nm for rod probes).
·The instrument has obtained multiple certificates and certifications, making it widely applicable. The sturdy and durable mechanical structure enables the instrument to adapt to harsh process conditions. Configuration settings and instrument calibration can be easily and quickly performed by pressing a key. It also contains anti condensation tubes, making its operation more reliable. It has bipolar electrostatic protection
The easily truncated pole (semi insulated) and cable (semi insulated and fully insulated) probes effectively reduce the storage cost of instruments
Solicap FTI77 universal capacitive limit switch, suitable for limit detection of small and rough solid particles, especially suitable for high temperature and high mechanical load measurement occasions
Solicap FTI77 semi insulated sword/cable probe is used for limit detection of small and rough particle solids. With its automatic adhesion compensation function, this probe can provide the highest measurement reliability, obtain various relevant certifications and licenses, and has a wide range of applications. The structure is sturdy and can perform high-precision measurements on abrasive media under extremely high lateral load conditions (the maximum load of the sword sensor is 800Nm).
E+H original imported intelligent capacitor level gaugeLimit detection/Solid
measuring principle | Capacitive level gauge |
Features/Applications | Fully/semi insulated rod sensor, used for level detection of small/large solid particles |
Easy calibration | |
Suitable for abrasive media | |
Sturdy structured sensors | |
Power/Communication | 19 . .. 253 V AC |
10 . .. 55 V DC-PNP | |
19... 253 V AC and 10... 55 V DC | |
8/16 mA, 11 ... 36 V DC | |
PFM | |
Three wire connection | |
ambient temperature | -50°C ... 70°C (-58°F ... 158°F) |
process temperature | -50°C ... 180°C (-58°F ... 356°F) |
Process pressure (absolute pressure)/maximum overpressure limit value | Vacuum .. 25 bar (362 psi) |
Main liquid receiving components | PE、PPS、316L、 steel |
Process connection | Thread: R1 1/2, NPT1 1/2 |
Flange: DN50.../ANSI 2 '.../JIS | |
sensor length | 0.2m ... 4m (8' ... 157') |
Shielding section length: 0.1... 1 m (2 '... 39') | |
output | 19-253 V AC, Two wire connection |
DC PNP | |
Relay DPDT | |
PFM | |
Three wire connection | |
8/16 mA | |
Certificate/Certification | ATEX |
FM | |
CSA | |
TIIS | |
SIL | |
characteristic | Shield segment length |
Automatic viscosity compensation function | |
Strong tensile load | |
The sensor structure is sturdy | |
Application Restrictions | DK:min 2 |
instrument | Integrated instrument |
Split type instrument | |
component | PFM:FTC325、FTC625、FTC470Z、FTC471Z |
Three wire connection: FTC325 |