The Defender530 flow calibrator is a new generation of dry gas flow meter. It is a primary flow meter and is recommended and used in conjunction with numerous individual sampling pump manufacturers. Can be used in the fields of industrial hygiene, environmental protection, and various laboratories. It adopts the principle of dry piston motion, and multiple consecutive readings can be generated with one button press. Compared with the traditional foam flowmeter, it is more convenient and fast to use. The 520 and 530 models have added the ability to simultaneously test temperature and pressure compared to the 510.
main features
Adopting the principle of dry piston, it is simple and convenient to use
Accurate flow control, certified by ISO17025
Compact structure
Large display screen
Up to 100 readings per group
Equipped with built-in temperature and pressure sensors to optimize test results (520 series)
Product parameters
specifications |
Defender 510 |
Defender 520 |
Defender 530 |
|
Model and flow range |
510L 5-500ml/min |
520L 5-500ml/min |
530L 5-500ml/min |
|
Flow accuracy |
1% |
1% |
1% |
|
Standard accuracy |
N/A |
N/A |
1.2% |
|
Optional measurement units |
internet traffic |
mL/min,L/min |
mL/min,L/min |
mL/min,L/min |
standardization |
N/A |
N/A |
smL/min,sL/min |
|
temperature |
N/A |
℃ or ℉· |
℃ or ℉ |
|
pressure |
N/A |
mmHg,PSI,kPa |
mmHg,PSI,kPa |
|
Temperature and pressure sensors |
No |
Yes |
Yes |
|
pressure |
N/A |
3.5 mmHg (typical) |
3.5 mmHg (typical) |
|
temperature |
N/A |
0.8 ℃ (typical) |
0.8 ℃ (typical) |
|
Time of each reading |
1-15 seconds |
|||
Reading mode (select the average of 1 to 100 measurements) |
Single (manual), continuous or burst mode |
|||
Gas compatibility |
Non corrosive gas, non condensing gas, humidity less than 70% |
|||
flow pattern |
Compression or suction |
|||
Measurement unit |
Integrated |
|||
AC/DC converter/charger |
12V DC,>250ma, 2.5mm center position |
|||
Type |
6V rechargeable sealed lead-acid battery, working time 6-8 hours |
|||
Battery running time (5 times/minute) |
Backlight on for 3 hours, backlight off for 8 hours |
|||
Press in or suction attachments |
hose |
|||
defects liability period |
1 year |
|||
storage temperature |
0-70℃ |
|||
air humidity |
0-70% |
|||
Operating pressure (absolute) |
15 PSI |
|||
display |
Backlit graphic LCD display |
|||
Data port (using optimization software) |
rs-232 serial port |
|||
Data cable (using optimization software) |
1-meter Defender calibrator to computer serial port |
|||
protection box |
Paper instrument box |
|||
Size (HxD) |
140x150x75mm |
|||
weight |
820g |