VIP member
Cycle preparation liquid chromatography LC-9210/9225NEXT (discontinued and upgraded to LaboACE series)
Cycle preparation liquid chromatography LC-9210/9225NEXT (discontinued and upgraded to LaboACE series)
Product details
Instrument Introduction:
□Reverse flow prevention function (patented device)
Completely solved the problem of cyclic preparationHPLCThe problem of backflow that once occurred due to back pressure damaging the detector and solvent peak. Ensure that the sample will not be lost in areas such as detectors and chromatography columns.
□Innovative design
The manual sampler is externally mounted, greatly reducing the time required for replacing sealing rings and other components. At the same time, infusion pumps and detectors can also be removed from the front end, greatly improving the maintainability of the instrument.
□Automatic cleaning function
The device is equipped with a brand new automatic cleaning component that can automatically clean the flow path. It can ensure that the instrument is used in a clean state. Similarly, utilizing this function can simplify the process of solvent replacement during chromatographic column replacement.
□Use shortcut keys to complete all settings
The device realizes that all settings from infusion to preparation can be completed through shortcut keys (infusion pump flow rate setting, detector setting, cycle switching, automatic cleaning, etc.).
Technical parameters:
|
LC-9210NEXT
|
LC-9225NEXT
|
|
Infusion pump:
|
FX-10
|
FX-25
|
|
Infusion method:
|
Double reciprocating double plunger pump
|
||
Maximum output pressure:
|
25MPa
|
0.1-9.9ml/min:
|
20MPa
|
10.0-19.9ml/min:
|
15MPa
|
||
20.0-25.0ml/min:
|
10MPa
|
||
Flow rate range:
|
0.01~10.0ml/min
|
0.1~25.0ml/min
|
|
control panel:
|
Shortcut keys
|
||
pressure display/Pressure limit:
|
Display through shortcut keys\\Setting up
|
||
Manual sampler:
|
Rheodyne 7725itype
|
||
Sample ring:
|
3 ml(Standard)
5ml,10ml(Optional)
|
10ml(Standard)
5ml,15ml(Optional)
|
|
Event marker:
|
Injection trigger, cycle trigger, collection trigger
|
||
Siphon counter:
|
Siphon table
|
||
Siphon mark:
|
Display siphon mark in detector signal
|
||
Circulating system:
|
Circulating system with backflow prevention function (patented equipment)
|
||
Loop mode:
|
Electromagnetic valve switching
|
||
Manual cycle:
|
Display through shortcut keys\\Setting up
|
||
Automatic cleaning system:
|
Clean according to program settings
|
||
Host size(mm):
|
464(W)×492(H)×504(D)
|
||
Host power supply:
|
85V-240Vpower800VA
|
||
Quality:
|
make an appointment38Kg
|