Beidouxing Industrial Chemistry Research Institute, Haidian District, Beijing
Home>Products>CPT2000-VOC Gas Alarm Beidou Satellite Instrument
CPT2000-VOC Gas Alarm Beidou Satellite Instrument
CPT2000-VOC gas alarm Beidouxing instrument, a transmitter and an alarm can form a point detection and alarm system
Product details

CPT2000-VOC gas alarm

CPT2000-VOC Gas Alarm Beidou Satellite InstrumentCommon infrared gas transmitters

Electrochemical gas transmitter

name

name

range

repeat

accuracy

specifications

Conditions of Use

other

methane

CH4

500-10000ppm

£ ±3%F

2312-ADS11

-10℃-40℃; 17-65%RH;

Methane, butane, natural gas. Anti alcohol natural gas/methane

R600A refrigerant leakage alarm

methane

CH4

500-10000ppm

£ ±3%F

2312-ADS11TH

-20℃-85℃; 1-99%RH

Methane, butane, natural gas. Anti alcohol

methane

CH4

500-10000ppm

£ ±3%F

2312-ADS11THP

-20℃-85℃; 1-99%RH;

0.34-2.04atm;

Methane, butane, natural gas. Anti alcohol

propane

C3H8

500-10000ppm

£ ±3%F

2312-ADE13A

-10-40;30-70%RH

Liquefied gas, oil mist/Oil and gasHydrogen gas, LP-Gas/Propane

propane

C3H8

500-10000ppm

£ ±3%F

2312-ADE16A-T200

-10℃-200℃; 30-70%RH

Liquefied gas, oil mist/Oil and gasHydrogen gas, LP-Gas/Propane

Organic gas

VOC

500-10000ppm;

£ ±2%F

2312-ADE16

-10℃-200℃; 0-95%RH

Various low molecular weight organic compounds, including hydrogen and carbon monoxide

Organic gas

VOC

500-10000ppm;

£ ±2%F

2312-ADE16

-10℃-200℃; 0-95%RH

T200E1m.Various low molecular weight organic compounds, including hydrogen and carbon monoxide; Equipped with a 1-meter extension pipe for air cooling;

Organic gas

VOC

0~100%LEL; 0-5%CH4

£ ±2%F

2410-4R

-10℃-50℃; 0-95%RH

Various low molecular weight organic compounds, including hydrogen and carbon monoxide

Organic gas

VOC

0~100%LEL; 0-5%CH4

£ ±2%F

2410T-4R

-10℃-50℃; 0-95%RH

Various low molecular weight organic compounds, including hydrogen and carbon monoxide

Organic gas

VOC

0~100%LEL; 0-5%CH4

£ ±2%F

2410TH-4R

-10℃-50℃; 0-95%RH

Various low molecular weight organic compounds, including hydrogen and carbon monoxide

Organic gas

VOC

0~100%LEL; 0-5%CH4

£ ±2%F

2410THP-4R

-10℃-50℃; 0-95%RH;

0.34-2.04atm;

Various low molecular weight organic compounds, including hydrogen and carbon monoxide

Organic gas

VOC

0~100%LEL; 0-5%CH4

£ ±2%F

2410TP-4R

-10℃-50℃; 0-95%RH;

0.34-2.04atm;

Various low molecular weight organic compounds, including hydrogen and carbon monoxide

Organic gas

VOC

50-5000ppm

£ ±5%F

2312-ADS20A

-10℃-40℃; 35-100%RH;

Alcohols, toluene, xylene, carbon monoxide, various organic gases

Organic gas

VOC

50-5000ppm

£ ±30%F

2312-ADE22

10-50;10-100%RH

Ketones, alcohols, benzene, hydrocarbons, hexane, butane, carbon monoxide, methane

Organic gas

VOC

50-5000ppm

£ ±3%F

2312-ADE23T

-20℃-200℃; 35-100%RH

Flange Jointing

Alcohols, toluene, xylene, carbon monoxide; Equipped with a 1-meter extension pipe for air cooling;

Organic gas

VOC

50-5000ppm

£ ±3%F

2312-ADE23TH

-20℃-200℃; 0-100%RH

Alcohols, toluene, xylene, carbon monoxide,

Organic gas

VOC

5-100ppm

£ ±30%F

2312-ADE25

10℃-50℃; 10-100%RH

Hydrogen sulfide, sulfide.

Organic gas

VOC

1-30ppm

£ ±10%F

2312-ADS02

10℃-50℃; 10-100%RH;

Toluene, benzene, xylene and other benzene derivatives (100%), alcohols, ammonia (20%), and various toxic gas alarms. Suitable for monitoring air quality in work environments.

Organic gas

VOC

>1-100ppm

£ ±30%F

2312-ADS00A

10℃-50℃; 10-100%RH

Methane, carbon monoxide, butane, alcohol, hydrogen

Organic gas

eVOC

0.1-100ppm

£ ±30%F

2610-EPO

-20℃-50℃; 15-90%RH

Acetaldehyde (40), acetylene (340), acrylonitrile (75), butadiene (170), carbon disulfide (140), carbon monoxide (100), thiocarbonyl (135), dimethyl sulfide (150), epichlorohydrin (50), methyl ethyl ketone (27), i-propanol (78), ethanol (180), ethylene (220), ethylene oxide (275), formaldehyde (330), methanol (415), methyl mercaptan (275), tetrahydrothiophene, thiophene (45), vinyl acetate (200), vinyl chloride (200), toluene (55),a-Pinene (88), ethyl acetate (39), ethylene oxide (275),

Organic gas

VOC

0-100% LEL

£ ±30%F

IR4110-HC

-20℃-50℃; 15-90%RH

EExdI/IIC T4

Class 1, Division 1, Groups A, B, C, D

Organic hydrocarbons, including alkanes, alkenes, alkynes, ketones, aldehydes, acids, esters, aromatic compounds, etc. Not responding to other inorganic gases of the same magnitude.

CPT2000-VOC Gas Alarm Beidou Satellite Instrument

1-1. Alkane gas transmitter at room temperature and atmospheric pressure:

Application:Methane, butane, natural gas. Anti alcohol.

CPT2312-ADS11 Volatile organic solvent concentration transmitterUsually equippedXM3.5-1 alarm

Technical parameters:

Range: 500-10000ppm;

Operating temperature: -10-40;

Sample humidity:17-65%RH;

Response speed T60:< 10s;

Non linearity:<±30% (through)XM3.5-1 Simple Linearization);

Main purpose: Over limit alarm

MTBF:>1 year;

1-2. Wall mounted alkane gas alarm:

Application:Methane, butane, natural gas. Anti alcohol.

W-CPT2312-ADS11Wall mounted alkane gas alarm

Technical parameters:

Range: 500-10000ppm;

Operating temperature: -10-40;

Sample humidity:17-65%RH;

Response speed T60:< 10s;

Non linearity:<±30% (through)XM3.5-1 Simple Linearization);

Main purpose: Over limit alarm

MTBF:>1 year;

Organic solvent evaporation alarm at room temperature and atmospheric pressure:

CPT2312-ADE22T Volatile organic solvent concentration transmitterUsually equippedXM3.5-1 alarm

Technical parameters:

Range: 50-5000ppm;

Operating temperature: -10-50;

Sample humidity:10-95%RH;

Response speed T60:< 10s;

Non linearity:<±30% (through)XM3.5-1 Simple Linearization);

Main purpose: Over limit alarm

MTBF:>1 year;

Organic solvent volatilization alarm under high temperature and atmospheric pressure:

CPT2312-ADE23T-F140 Volatile organic solvent concentration transmitter is usually equipped withXM3.5-1 alarm

Technical parameters:

Range: 50-5000ppm;

Operating temperature: -10-200;

Sample humidity:10-95%RH;

Response speed T60:< 10s;

Non linearity:<±10% (through)XM3.5-1 Simple Linearization);

Main purpose: Over limit alarm

MTBF:>1 year;

Organic solvent volatilization concentration detection transmitter under high temperature and atmospheric pressure:

TBD5-CPT2312-ADE23T-F140 Volatile organic solvent concentration transmitter

Can be equipped with a remote transmission secondary watchXM3.5-1 alarm

Or directly output switch signals to drive switch quantity control;

Or output analog adjustment signals for closed-loop control;

Technical parameters:

Range: 50-5000ppm;

Operating temperature: -10-200;

Sample humidity:10-95%RH;

Response speed T60:< 10s;

Non linearity:<±10% (through)TBD5 linearization);

Main applications: concentration detection, over limit alarm, or control;

MTBF:>1 year;

Beijing Beidouxing Industrial Chemistry Research Institute

Shaanxi Fusaisi Instrument Co., Ltd

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!