1、 Product Introduction:

1. Temperature range: ambient temperature plus 5 ℃ to 300 ℃

2. Up to 30% more energy-efficient than common devices on the market

3. Utilizing APT.line ™ Technology achieves high temperature accuracy

4. Natural convection

5. Controller with LCD display

6. Exhaust valve electromechanical control

7. 2 chrome plated sockets

8. Integrated independently adjustable temperature safety device level 2 (DIN 12880) with optical alarm

9. Ergonomic handle design

10. USB interface for recording data

2、 Technical parameters:

PRODUCT MODEL ED260-230V1 ED260UL-240V1
Choose a model standard standard
Item code 9010-0339 9010-0340
measure
Internal volume [L] 255 255
Net weight of equipment (unloaded) [kg] 85 85
Maximum total load [kg] 270 270
Maximum load per partition [kg] 40 40
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 810 810
Net weight at height [mm] 965 965
Depth net weight [mm] 760 760
Wall distance from rear [mm] 160 160
Wall to side distance [mm] 100 100
Internal dimensions
Width [mm] 610 610
Height [mm] 760 760
Depth [mm] 550 550
The number of doors
Outer door 1 1
Data related to the environment
Energy consumption at 150 ℃ [Wh/h] 355 355
firmware
Number of partitions (hours/maximum) 2/8 2/8
Temperature performance data
The temperature range exceeds the indoor temperature by 5 ℃ to [℃] 300 300
Temperature deviation is 150 ℃ [± K] 1.8 1.8
Temperature fluctuation at 150 ℃ [± K] 0.8 0.8
Heating time to 150 ℃ [min] 50 50
The recovery time after opening the door in 30 seconds is 150 ℃ [min] 20 20
Electric data
Rated voltage [V] 230 240
Power frequency [Hz] 50/60 60
Rated power [kW] 2.25 2.45
Equipment safety device [A] 12.5 16
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. We reserve the right to make technical changes.