Shanghai Aoxi Scientific Instrument Co., Ltd
Home>Products>Atomic absorption spectrophotometer AA3510
Atomic absorption spectrophotometer AA3510
The atomic absorption spectrophotometer AA3510 is composed of product engineers and application engineers with decades of experience in atomic absorpt
Product details

atomic absorption spectrophotometer

    1. AA3510Faas
    2. AA6810Faas

atomic absorption spectrophotometerPhysical pictures of the instrument:

6810type 3510type

TECHNICAL INDEX

host

Wavelength range 190-900nm

4/6Lamp lighthouse multi-element analysis does not require lamp replacement

Wavelength repeatability ± 0.1nm

Wavelength accuracy: ± 0.2nm across the entire wavelength range

Absorption range 0-2.5 ABS

When the resolution spectral bandwidth is 0.2nm, it can separate manganese double lines (279.5 and 279.8)

And the valley peak energy ratio is less than 20%

Spectral bandwidth (6 levels, 4 levels optional) 0.1nm, 0.2nm, 0.4nm, 0.7, 1.0, 2.0nm

Static baseline drift ≤ 0.002ABS/30min (Cu)

Weight 80kg

Size 500 * 450 * 430 (mm)

Number of gratings 1800/mm

D2Background subtraction method: When the background signal is 1ABS, the ability to deduct background is ≥ 50 times

Self absorption background deduction method

Power supply 220V AC

Flame system

Air acetylene flame combustion head 100mm

Laughing gas acetylene flame combustion head 50mm

Ignition dynamic baseline drift ≤ 0.004ABS/30min (Cu)

Precision relative standard deviation ≤ 0.5% (Cu, absorbance>0.8ABS)

Detection limit: Cu ≤ 0.004ug/ml

Automatic cut-off of gas in case of insufficient pressure, power interruption, abnormal shutdown, or mismatched combustion head in the safety system

main features

All functions are controlled and operated by a PC, and flame and graphite furnaces can be flexibly selected. Unique optical mechanical design, safe and convenient flame system, advanced graphite furnace temperature control technology, optional background technology deduction, and various convenient functions provided by the workstation, adapt to your pursuit of precise measurement results in automation.

AA6810The following improvements have been made on the basis of the original Agilent AA4510:

  • Using highly sensitive flame sensors to eliminate interference from external light
  • Realize safer control over abnormal situations, such as insufficient pressure, air leakage, engine shutdown, etc
  • The simple lifting platform structure makes it easier for users to adjust
  • Added working software for the hydride generator method
  • Provide 6 levels of slits 0.1, 0.2, 0.4, 0.7, 1.0, 2.0
  • Can install 6 hollow cathode lamps simultaneously
  • The software has added a method storage function, allowing users to retrieve standard curves at any time after storage, which can save analysis time

FaasAA 3510giveAA 6810Configuration Difference Table

project

AA 3510Type configuration

AA 6810Type configuration

optical performance

Wavelength Repeatability

±0.1nm

±0.1nm

Wavelength accuracy

Full band ± 0.2nm

Full band ± 0.15nm

Range of absorbance

0–2.5ABS

0–2.5ABS

Static baseline drift

≤0.002ABS/30min(Cu)

≤0.002ABS/30min(Cu)

Grating number

1800Strip/mm

1800Strip/mm

resolution

At a spectral bandwidth of 0.2nm, manganese double lines (279.5 and 279.8) can be separated

And the valley peak energy ratio is less than 30%

At a spectral bandwidth of 0.2nm, manganese double lines (279.5 and 279.8) can be separated

And the valley peak energy ratio is less than 20%

Flame system

Air acetylene flame combustion head

100mmOptional laughing gas function (50mm)

100mm

Gas flow control

hand movement

automatic

Alarm for insufficient pressure of air, acetylene, and laughing gas

have

have

Real time monitoring of flame status

not have

have

Dynamic baseline drift of ignition

≤0.004ABS/30min(Cu)

≤0.004ABS/30min(Cu)

Sensitivity (Cu) characteristic concentration

≤0.025ug/ml/1%

≤0.02ug/ml/1%

detection limit

0.008ug/mL

0.004 ug/mL

Relative standard deviation of precision

≤ 0.5% (Cu, absorbance>0.8ABS)

≤ 0.5% (Cu, absorbance>0.8ABS)

lamp holder

4light point

6light point

slit

0.1, 0.2 , 0. 4, 1.0 ( 4files)

0.1, 0.2, 0.4, 0.7,1.0, 2.0 (6files)

atomizing cup

engineering plastic

stainless steel

Button background

Deuterium lamp clip background

Deuterium lamp, self absorbing buckle background

software upgrading

charge

free

Expansion function of graphite furnace(interface)

not have

pre-install

4、 The standard configuration is shown in the table below

Configuration Attachment List

Serial Number

product name

model

quantity

unit

1

6810

Standard type

1

tower

2

air compressor

no oil

1

tower

3

hollow cathode lamp

2

only

4

software

AA6810workstation software

1

fix

5

computer

Hewlett-Packard

1

tower

6

100mmcombustion head

1

individual

7

Acetylene pressure reducing valve

1

individual

8

Acetylene pipeline

10

rice

9

LAMP

1

individual

10

tool

Screwdrivers, wrenches, etc

5

grasp

11

sealing washer

8

individual

12

Regarding the light plate

1

individual

13

data line

1

root

14

power line

1

root

15

fuse

7

root

16

Waste liquid pipe

1

root

17

instructions

1

share

18

atomizer

1

only