Application of Siemens Ultrasonic Flow Meter in GermanySafety, efficiency, and smooth operation are the lifelines of a factory. Level measurement technology plays multiple important roles in production operations, either alone or in conjunction with other instruments. Siemens' point level measuring devices can meet all needs, from backup alarms, material occurrence detection and/or point level monitoring, air transportation protection to economically effective material detection. Capacitive, ultrasonic, resistive or vibrating level switches are suitable for almost all applications of bulk materials, liquids, and materials in between.Siemens non-contact ultrasonic level switch is suitable for level detection of dispersed solid materials, liquids, and slurries in a wide range of fields.
The Pointek ULS200 is an ultrasonic non-contacting switch with two switch points for level detection of bulk solids, liquids and slurries in a wide variety of industries; ideal for sticky materials. The measuring range for bulk solids is max. 3 m (9.8 ft) and 5 m (16.4 ft) for liquids and slurries. Unlike invasive contacting devices, there is no material buildup on the sensor.
Measurement levelEN1434 |
|
2 |
pressure loss |
bar |
0 |
sampling frequency(On Battery) |
Hz |
0,5 |
sampling frequency(AC power supply) |
Hz |
15 |
medium temperatureDN50-1200Integrated |
°C |
2...120 |
medium temperatureDN50-80,bronze,split type |
°C |
2...150 |
medium temperatureDN100-1200,carbon steel,split type |
°C |
2...200 |
MIDMinimum certified medium temperature |
°C |
15 |
ambient temperature |
°C |
-10...55 |
storage temperature(Does not include battery) |
°C |
-35...85 |
environmental rating |
|
E2, M1 |
Flange standard |
|
EN 1092-1 |
Application of Siemens Ultrasonic Flow Meter in Germanycharacteristic:
lDynamic range can reach1:100
lThe principle of dual channel ultrasonic measurement can achieve accuracy. Flow measurement frequency20Hz.
l MIDCertified flow meters suitable for heating and cooling systems,EN1434 2Level,OIML R75 2Grade. Actual measurement accuracy Degree better than0.5%.
lFlow meter and transmitter are installed separately, with a line length of up to30Rice, the working temperature of the medium can reach200℃
lNo pressure loss
lDigital output optoelectronic isolation, no potential impact
lsplit typeIP67Flow meter, can be upgraded on-site toIP68Soaking has no effect.
lAC power supply, typical service life of backup battery in case of AC power failure6Year (typical usage: power outage once a day) Next time, every time it lasts1Hour).