1. Product Overview
The accumulator shut-off valve is one of the accessories of hydraulic one bag accumulator, mainly used for safe shut-off and unloading, and also provides convenience for maintenance and replacement. The main valve structure is a hydraulic balance cone valve type, which has the characteristics of small operating torque and reliable sealing. According to the connection method, there are three types of accumulator globe valves: straight through, right angle, and three-way threaded connection. The XJF type accumulator globe valve is a high-quality accumulator globe valve independently developed by Asahi Hydraulic based on foreign data. Its main valve core is a hydraulic balance cone valve type, and this valve is designed with a discharge port specifically for the disassembly of the accumulator, which can replace imported accumulator globe valves.
2. Functional features
Used to achieve the functions of on/off, pressure relief and oil release between the accumulator and the system, while maintaining the pressure setting value in the system. The specific principle is as follows: when the pressure exceeds the set value, the shut-off valve opens to prevent system overload. Especially for energy storage devices installed in closed systems, shut-off valves can prevent the harm caused by sudden pressurization of external loads to the system, making them indispensable..
3. Model Description
XJF _ ※/※
① ② ③
① Name code: accumulator globe valve
② Nominal diameter: 10, 20, 32, 40, 50mm
③ Discharge port diameter: 10mm
4. Technical parameters
Nominal pressure: 10-31.5Mpa
Applicable media: mineral oil, water ethylene glycol, and emulsion
Medium stability: -10 ℃ to+93 ℃
5. Structural principle

model |
Nominal Diameter (mm) |
nominal pressure (mm) |
Discharge port diameter (mm) |
Basic dimensions (mm) |
|||||||||||||||||
L |
L1 |
L2 |
W1 |
W2 |
H1 |
H2 |
H3 |
D |
D1 |
D2 |
D3 |
||||||||||
XJF-10/10 |
10 |
10 20 31.5 |
10 |
58 |
44 |
163 |
10 |
170 |
10 |
20 |
226 |
60 |
10 |
17.8 |
27 |
||||||
XJF-20/10 |
20 |
58 |
44 |
163 |
10 |
170 |
10 |
20 |
226 |
60 |
20 |
28.5 |
38 |
||||||||
XJF-32/10 |
32 |
76 |
53 |
190 |
12 |
225 |
16 |
26 |
283 |
80 |
32 |
43 |
55 |
||||||||
XJF-40/10 |
40 |
92 |
8 |
207 |
46 |
250 |
16 |
26 |
275 |
80 |
40 |
51 |
62 |
||||||||
XJF-50/10 |
50 |
100 |
10 |
210 |
50 |
280 |
16 |
38 |
316 |
90 |
50 |
61 |
65 |
||||||||
model |
Basic dimensions (mm) |
Applicable accumulator models |
weight Kg |
||||||||||||||||||
D4 |
D5 |
D6 |
D7 |
D8 |
DM |
||||||||||||||||
XJF-10/10 |
12 |
18 |
24 |
125 |
92 |
M42×2 |
NXQ-1.6~10/※-L-A |
7 |
|||||||||||||
XJF-20/10 |
12 |
18 |
24 |
125 |
92 |
M42×2 |
7 |
||||||||||||||
XJF-32/10 |
12 |
18 |
24 |
155 |
107 |
M60×2 |
NXQ-1.6~100※-L-A |
13 |
|||||||||||||
XJF-40/10 |
12 |
M22×1.5 |
40 |
155 |
107 |
M60×2 |
16 |
||||||||||||||
XJF-50/10 |
12 |
M22×1.5 |
40 |
155 |
107 |
M72×2 |
25 |
6. Common faults
① Internal leakage: The possible reason is impurities on the sealing surface, which can be cleaned with kerosene; If the sealing surface is damaged, it needs to be processed by professional personnel.
② Leakage: Generally, the cause of leakage is damage to the packing. In this case, simply replace the packing and pay attention to tightening it appropriately.
7. Ordering Instructions
① When placing an order, the full name of the model code must be specified, such as: XJF-32/10 for an accumulator globe valve with a working pressure of 31.5Mpa and a diameter of 32mm;
② If there are any special requirements for this shut-off valve, please consult with our company;
③ Our company reserves the right to make design changes without prior notice.