Dongguan Chanlin Electronics Co., Ltd
Home>Products>A8GS remote reset boat shaped switch
A8GS remote reset boat shaped switch
Product Category: Omron Boat shaped Switch Product Description: The industry's smallest boat shaped switch with reset function ▶ By using the "reset
Product details

Types

Type with reset function

Contact method Single blade single throw type(SPST) Minimum packaging unit
1~2: Power contact terminal Small load contact terminal x 1 Power contact terminal x 1
a. B: Small load contact terminal      
+, -: Coil terminal
Terminal specifications CT connector # 187 terminal block (t=0.8) Welding terminals
Reset voltage 5V 3.3V 5V 3.3V 5V 3.3V
Button marking not have A8GS-S1105 A8GS-S1103 A8GS-P1185 A8GS-P1183 A8GS-P1115 A8GS-P1113 50 of them
  A8GS-S1205 A8GS-S1203 A8GS-P1285 A8GS-P1283 A8GS-P1215 A8GS-P1213
  A8GS-S1305 A8GS-S1303 A8GS-P1385 A8GS-P1383 A8GS-P1315 A8GS-P1313

Contact method Double Knife Single Throw (DPST) Minimum packaging unit
1~2: Power contact terminal Small load contact terminal x 1+power contact terminal x 1
a. B: Small load contact terminal  
+, -: Coil terminal
Terminal specifications Micro load contact terminal: CT connector Micro load contact terminal: CT connector
Power contact terminal: # 187 terminal block (t=0.8) Power contact terminal: welded terminal
Reset voltage 5V 3.3V 5V 3.3V
Button marking not have A8GS-C1185 A8GS-C1183 A8GS-C1115 A8GS-C1113 50 of them
  A8GS-C1285 A8GS-C1283 A8GS-C1215 A8GS-C1213
  A8GS-C1385 A8GS-C1383 A8GS-C1315 A8GS-C1313

Contact method Double blade single throw type(DPST) Minimum packaging unit
1-4: Power contact terminals Power contact terminal×2
a. B: Small load contact terminal  
+, -: Coil terminal
Terminal specifications 187Terminal block(t=0.8) Welding terminals
Reset voltage 5V 3.3V 5V 3.3V
Button marking not have A8GS-D1185 A8GS-D1183 A8GS-D1115 A8GS-D1113 50 of them
  A8GS-D1285 A8GS-D1283 A8GS-D1215 A8GS-D1213
  A8GS-D1385 A8GS-D1383 A8GS-D1315 A8GS-D1313

Note 1. The model of TV-8 certification type is marked with "V" at the end. (Example: A8GS-P1185V, A8GS-C1185V, A8GS-D1185V)

Note 2. Only the power contact terminals are TV-8 certified. For details, please consult.

Note 3. The end of the model with a reset voltage of 3.3V specification is' 3 '(e.g. A8GS-P1183). The model with a reset voltage of 5V specification ends with '5' (e.g. A8GS-P1185).

Non reset function type

Contact form Single Knife Single Throw (SPST) Double Knife Single Throw (DPST) Minimum packaging unit
1-4: Power contact terminals Small load contact terminal x 1 Power contact terminal x 1 Power contact terminal×2
a. B: Small load contact terminal      
 
Terminal specifications CT connector # 187 terminal block (t=0.8) Welding terminals # 187 terminal block (t=0.8) Welding terminals
Button marking not have A8GS-S1100 A8GS-P1180 A8GS-P1110 A8GS-D1180 A8GS-P1110 50 of them
  A8GS-S1200 A8GS-P1280 A8GS-P1210 A8GS-D1280 A8GS-P1210
  A8GS-S1300 A8GS-P1380 A8GS-P1310 A8GS-D1380 A8GS-P1310
Contact form Double Knife Single Throw (DPST) Minimum packaging unit
1-4: Power contact terminals Small load contact terminal x 1+power contact terminal x 1
a. B: Small load contact terminal  
 
Terminal specifications Small load contact terminal:CTConnector, power contact terminal: #187Terminal block(t=0.8) Small load contact terminal:CTConnector, power contact terminal: welded terminal
Button marking not have A8GS-C1180 A8GS-C1110 50 of them
  A8GS-C1280 A8GS-C1210
  A8GS-C1380 A8GS-C1310

Note 4. The same type of switch as a regular ship type switch without a reset function.

RATING

contact

project Resistive load (A)
Rated voltage (V)
Power contact terminal AC 125 16
AC 250 10
Small load contact terminal DC 5 0.2

Note 1. The above rated values are data measured under the following conditions.
(1) Environmental temperature: 20 ± 2 ℃
(2) Environmental humidity: 65 ± 5%
(3) Operating frequency: 7 times/min

Reset Coil

form Rated voltage and current Operating voltage range Rated service life Coil resistance (coil temperature 20 ± 2) ℃

Reset voltage 5V specification

A8GS-______5

DC5V 455mA DC4.5~5.5V ON:50~100ms; OFF: Minimum 5 seconds 11Ω±20%

Reset voltage 3V specification

A8GS-______3.3

DC3.3V 300mA DC3.0V~3.6V ON:50~100ms; OFF: Minimum 5 seconds 11Ω±20%

Note 1: Please control the voltage of the coil to be within the operating voltage range and use the power on time within the rated service life. Otherwise, it may damage performance.
Note 2. If you wish to use the power supply voltage within the range of DC5.5V to DC24V, please consult separately.

■ Contact specifications

Small load contact point Power contact point
material gold alloy silver alloy
Contact interval 3mm or more 3mm or more
Minimum applicable load (reference) * DC3V 1mA DC5V 200mA

Use the load when the switch is turned on within a range not lower than the minimum applicable load.
For the minimum applicable load, please refer to "About the use in small loads" in "Please use correctly".

■ Performance

Allowable operating frequency machinery Switch operation: 20 times/min or less, coil operation: 7 times/min or less
electrical Below 7 times per minute
insulation resistance 100M Ω or above (DC500V megohmmeter)
Contact resistance (initial value) Power contact terminal Below 100m Ω (DC6~8V, 1A voltage drop method)
Small load contact terminal Below 100m Ω (DC6~8V, 0.1A voltage drop method)
pressure resistance Between terminals of the same polarity AC2,000V 50/60Hz 1min
Between opposite polarity terminals AC2,000V 50/60Hz 1min
Between the coil and the switch terminal AC4,000V 50/60Hz 1min
Between the charged metal part and the ground AC4,000V 50/60Hz 1min
Vibration * malfunction 10-55Hz dual amplitude 1.5mm (misoperation within 1ms)
Impact * malfunction 300m/s2 or above (misoperation within 1ms)
durable Maximum 1000m/s2
Temperature range for use -10~+55 ℃ (no freezing, no condensation, below 60% RH)
Environmental humidity for use Below 90% RH (+5-35 ℃, without freezing or condensation)
lifetime machinery Switch operation: over 30000 times, coil operation: over 10000 times
electrical Switching operation: more than 10000 times
Impulse current Maximum 117A
Protective structure IEC IP40
Contact disconnection time * * Below 100ms
weight A8GS-S □□□□: about 9g, A8GS-P □□□□: about 10g, A8GS-C □□□□: about 11g, A8GS-D □□□□: about 12g

Note 1: The above values are initial values.
Please inquire separately about the experimental conditions.
***** Reset fromThe time it takes for the coil to apply voltage until the contact is disconnected.

(Unit: mm)
A8GS-S1□ 05

A8GS-S1□ 03

operating characteristic

Action force (OF) 1.0± 0.6N

A8GS-P1□ 85

A8GS-P1□ 15

A8GS-P1□ 83

A8GS-P1□ 13

operating characteristic

Action force (OF) 1.5± 0.9N

A8GS-C1□ 85

A8GS-C1□ 15

A8GS-C1□ 83

A8GS-C1□ 13

Action characteristics

Action force (OF) 2.0± 1.2N

A8GS-D1□ 85

A8GS-D1□ 15

A8GS-D1□ 83

A8GS-D1□ 13

Action characteristics

Action force (OF) 2.0± 1.2N

A8GS- □□□□ 0
(No reset function)

The model diagram is based on A8GS-S1100.
The non reset function type refers to products that have removed the coil part.
There is no difference in the action characteristics and performance between products with and without reset function.

Optional parts (sold separately)
By installing a protector, the tolerance to external forces applied to the operating part from the horizontal (oblique) direction can be improved.

protector
A8GS-211(P)
Color: Black
installation diagram

Note 1. In the above dimensional drawing, the tolerance not indicated is ± 0.4mm.
Note 2. When operating from the OFF state after reset to the ON state, the operating force increases due to the switch structure.
Note 3. The appearance and characteristics of TV-8 certified switches are the same as those of general products.

*For the welded terminal type, only the shape of the central hole of the terminal has been changed, and there have been no changes to the switch, terminal shape, characteristics, etc.
■ Panel processing diagram

Installation panel thickness: 0.8-2.3mm
To prevent accidental insertion, the installation holes are asymmetric in shape,
Please pay attention to the direction of the protrusion.
Please process the rounded corners R of the panel on the surface of the panel.
Please process the buckle on the back of the panel.

Note 1: The recommended standard material for the panel is SPCC. If flexible materials are used or there are no buckles on the back of the panel, it may result in insufficient fixing force of the panel. Therefore, please set the panel thickness and size after confirming the actual usage conditions.

warn

Do not perform wiring operations while the switch is powered on.

Do not touch the terminals when powered on. Otherwise, it may cause electric shock.

Safety points

·Please use within the electrical rating range.If used beyond the rated value, it will not only reduce the durability of the switch, but also cause heating and burningBad and dangerous. Therefore, the instantaneous voltage and current during use, including on and off, should be consideredWithin the rated range.

Precautions for use

Regarding installation

·One touch installation.

·Do not apply excessive force when installing the switch into the panel.

·Do not remove the switches already installed on the panel and reinstall them on the panel for use.

·When installing switches on the panel, do not apply external force to the buttons to ensure that the load is appliedShell and flange parts.


Regarding wiring

·When using terminal blocks, please use the socket suitable for terminal block # 187 (t=0.8).

·Please use wires of the correct specifications that can meet the load current.

·After wiring, please avoid subjecting the terminal and connector parts to external forces at all times. Otherwise, it may lead toCausing damage and misoperation of the switch.

(Example: Constant external force state caused by excessive winding of steel cables, etc.)

·After wiring, an appropriate insulation distance should be maintained between the switch terminals and other metal parts.

·The coil has polarity, please confirm the polarity before wiring correctly.

·When continuous power is applied in the coil, insulation aging may occur due to coil heating. Therefore, designWhen using the circuit, please ensure that it is continuously powered on for no more than 10 seconds.

·The back electromotive force generated after the coil action may cause damage to semiconductor components and device errors

Action.When controlled by precision semiconductor components, please design additional surge absorption circuits and other circuits.

·When welding manually, please use an electric soldering iron (with a tip temperature of 360 ℃ MAX) to complete the welding within 4 secondsConnect and do not apply external force to the terminals.

·The contact of the soldering iron tip with the root of the terminal can cause deformation of the switch housing and base.

Regarding usage

·Do not apply external forces to the product that may cause it to deform or deteriorate.

·Please avoid dropping the switch or applying abnormal impacts.Otherwise, it will lead to poor movement.

·Do not apply load to the operating part horizontally (diagonally).Otherwise, it will cause damage to the switch.


Regarding storage and usage environment

·To prevent terminal discoloration and other aging and deterioration of this product during storage, please avoid using the following methodsLong term storage and use under the specified conditions.

1. High temperature and humid environment

2. Environments with corrosive gases

3. Places with direct sunlight

4. Places invaded by sea breeze

5. Environment with rapid temperature changes

In addition, this switch is not sealed and should not be installed in places that come into contact with water, oil, and dustInstallation and use.

·Do not freeze or condense the switch.

·Using in places with strong external magnetic fields may result in improper operation. Please use it in its actual stateConfirm.

Regarding the use of small loads in the field

For use with small loads, please refer to the minimum applicable load current and voltage values, and followSet values higher than these.

If surge current is generated during switching, it will cause the contact to consume too quickly and reduce durabilitySex, therefore please insert contact protection lines as needed.

The minimum applicable load is based on the L level as the reference value.

This value represents a fault level with a reliability level of 60% (λ 60).(JIS C5003)

λ 60=0.5 × 10-6/time is the reliability level of 60%, indicating a prediction of 1-2,000,000Below NextThe malfunction.

● Compliant with RoHS directive

It is recorded that products that comply with RoHS do not contain the following six substances.

<Reference>

The conformity judgment of 6 substances is based on the following criteria.

Lead: below 1000ppm

Mercury: below 1000ppm

Cadmium: below 100ppm

Hexavalent chromium: below 1000ppm

PBB: below 1000ppm

PBDE: below 1000ppm

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!