The Mettler Toledo Thornton 450TOC total organic carbon analyzer can quickly monitor changes in TOC and is easy to move and transport. The sturdy and portable 450TOC is an ideal choice for on-site multi-point measurement of TOC, water system diagnosis, and maintenance verification.
450TOC features
• Portable, fast response measurement
Continuous measurement technology, perfect design and performance
The USB port stores measurement data through a memory stick
USB printers support hard copy recording
• Compliant with USP, Ch P, EP, and JP requirements
Portable TOC analyzer
Portable TOC analyzer reduces system certification time by 80%
The analyzer 100% meets the requirements of fast, simple, and convenient point of use measurement
On site rapid measurement of TOC and conductivity, saving 80% of system diagnostic time
• Quickly collect measurement data through a USB memory stick and export it very easily
Direct on-site measurement eliminates errors caused by sampling laboratory analysis
450TOC performance parameters
TOC sensor
Measurement range 0.05-1000 gC/L (ppbc)
Measurement accuracy ± 0.1 ppb C TOC<2.0 ppb (water quality>15 M Ω - cm [<0.067 μ S/cm])
± 0.2 ppb C 2.0 ppb<TOC<10.0 ppb (water quality>15 M Ω - cm)
± 5% TOC reading>10.0 ppb (water quality 0.5~18.2 M Ω - cm)
Repeatability ± 0.05 ppb C<5 ppb, ±1.0% > 5 ppb
Resolution 0.001 ppbc (μ g C/L)
Continuous measurement time
Initial usage time<60 seconds
Detection limit 0.025 ppbc
TriE Conductivity Sensor
Conductivity accuracy ± 1%, 0.02 - 20 μS/cm; ±3%, 20 - 100μS/cm
Electrode constant accuracy 2%
Temperature sensor P t1000 RTD, Class A
Temperature accuracy ± 0.25 ° C
Requirements for injection water
Temperature 0 to 70 ° C
Particle size<100 microns
The water quality requirement for injection is 0.5M Ω - cm (2 μ S/cm), with a pH<7.5*
Flow rate 20mL/min
Pressure sample inlet 4 to 85 PSI (0.3 bar to 5.8 bar)
General
Shell size 334 x 185 x 324mm (13.15 "L x 7.3" W x 12.75 "H)
Sample Connection
Inlet outer diameter 3mm (0.125 ") (provide 2 m (6 ') PTFE hose that meets FDA requirements)
Export outer diameter 3mm (0.125 ") stainless joint (1.5m (5 ') hose)
Inlet filter 316SS, built-in 60 micron filter cartridge
Weight including base: 7.0kg (15.4 lb); without base: 6.1kg (13.6 lb.)
The shell material is fireproof polystyrene resin, which can refer to UL 94 V-0
General Parameters (Continued)
Liquid bonded components 316SS/quartz/PEEK/titanium/PTFE/silicon/FFKM/EPDM
Environmental temperature/relative humidity 5-50 ° C/5-80% relative humidity, no condensation
Power supply 100-240VAC, 50/60Hz; Maximum power: 40W
The panel displays four LED lights indicating faults, warnings, electrode status, and UV light switch
Grade/certification meets CE requirements and has passed cULus certification
Conductivity and temperature sensors can be traced back to NIST, ASTM D1125, and D5391
The testing method for online monitoring of carbon compounds in water through ultraviolet oxidation complies with ASTM D5173 standard
Requirements for testing methods